{"id":1009,"date":"2017-06-12T20:23:04","date_gmt":"2017-06-12T20:23:04","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=1009"},"modified":"2017-06-12T20:23:04","modified_gmt":"2017-06-12T20:23:04","slug":"controllogix-trending","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/","title":{"rendered":"ControlLogix Trending"},"content":{"rendered":"<h2>Introduction to ControlLogix Trending<\/h2>\n<p>ControlLogix Trending will track values over time. \u00a0 Most commonly, you will use trending on analog values, but it can be used to track digital (discrete on\/off) signals as well. \u00a0Think of trending as a &#8220;software chart recorder&#8221;.<\/p><div id=\"bryce-1518047784\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n<p>In this example, we will use trending to track a Pipe Pressure over time. \u00a0 The pipe pressure will run from 0 to 200 psi over a period of 20 seconds. \u00a0If the pipe is not holding pressure, we would see that on the trend chart. \u00a0This could indicate a failure in a seal. \u00a0 If you have not done so, refer to my post <a href=\"https:\/\/bryceautomation.com\/index.php\/2017\/06\/01\/controllogix-analog\/\">&#8220;ControlLogix Analog&#8221;<\/a> to learn how to set up and scale your analog module.<\/p>\n<h2>Create your Trend<\/h2>\n<p>To create a Trend, right-click the trends folder in the Controller Organizer window, and select &#8220;New Trend&#8221;.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1010 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/NewTrend.png\" alt=\"New Trend\" width=\"249\" height=\"73\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 249px; --smush-placeholder-aspect-ratio: 249\/73;\" \/><\/p>\n<p>Next, name your trend and choose the sample period. \u00a0 The sample period is how often the pen will update it&#8217;s data on your chart. \u00a0 Here, we will choose 100 ms. \u00a0Click &#8220;Next&#8221;.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1011 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/TrendName.png\" alt=\"Trend Name\" width=\"443\" height=\"175\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/TrendName.png 443w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/TrendName-300x119.png 300w\" data-sizes=\"(max-width: 443px) 100vw, 443px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 443px; --smush-placeholder-aspect-ratio: 443\/175;\" \/><\/p>\n<p>Select the tags you wish to trend. \u00a0 Then you will click the &#8220;Add&#8221; button, and your tag will appear under the box for &#8220;Tags to Trend&#8221;. \u00a0 \u00a0After you have added your tags, click &#8220;Finish&#8221;. \u00a0Your Trend is now created.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1012 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/TrendCreated.png\" alt=\"Trend Created\" width=\"562\" height=\"430\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/TrendCreated.png 562w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/TrendCreated-300x230.png 300w\" data-sizes=\"(max-width: 562px) 100vw, 562px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 562px; --smush-placeholder-aspect-ratio: 562\/430;\" \/><\/p>\n<h2>Adjust the Scale<\/h2>\n<p>First of all, look at the time across the bottom of your chart. \u00a0 You will see we are only looking at a 2 second time period. \u00a0 The amount of time across the bottom is called the &#8220;X Axis&#8221;. \u00a0 \u00a0Another adjustment to make is the scale on the left edge of your chart. \u00a0 By default, this is set to Automatic mode. \u00a0 \u00a0 This means the scale will change based on actual data. \u00a0 At times, this can cause confusion though. \u00a0 We will lock in the values of 0 to 200 psi. \u00a0This scale is referred to as the &#8220;Y Axis&#8221;.<\/p>\n<p>To configure the scaling, right-click anywhere on the chart, and go to &#8220;Chart Properties&#8221;. \u00a0I will click on the &#8220;X Axis&#8221; Tab, and change the time span to 2 minutes.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1014 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/Xaxis.png\" alt=\"X Axis Configuration\" width=\"626\" height=\"229\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/Xaxis.png 626w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/Xaxis-300x110.png 300w\" data-sizes=\"(max-width: 626px) 100vw, 626px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 626px; --smush-placeholder-aspect-ratio: 626\/229;\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>Also, we will go to the &#8220;Y Axis&#8221; Tab, and you will find 3 options. \u00a0 In Automatic mode, the scale is adjusted to fit based on actual data. \u00a0 In Preset mode, we will put a minimum an maximum value into the &#8220;Pens&#8221; tab for each pen. \u00a0 The other option is to lock in a custom value. \u00a0 \u00a0Since we anticipate tracking more than one value some day with different scales, we will choose &#8220;Preset&#8221;.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1015 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/Yaxis.png\" alt=\"Y Axis Trending\" width=\"625\" height=\"133\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/Yaxis.png 625w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/Yaxis-300x64.png 300w\" data-sizes=\"(max-width: 625px) 100vw, 625px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 625px; --smush-placeholder-aspect-ratio: 625\/133;\" \/><\/p>\n<p>Furthermore, since we chose &#8220;Preset&#8221;, we will need to go to the &#8220;Pens&#8221; tab, and add a minimum and maximum value for the &#8220;PipePressure&#8221; pen. \u00a0While you are here, you can also adjust the color of the pen, and the width to make your pen more visible.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1016 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/PensTab.png\" alt=\"Trending Pens Tab\" width=\"628\" height=\"132\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/PensTab.png 628w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/PensTab-300x63.png 300w\" data-sizes=\"(max-width: 628px) 100vw, 628px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 628px; --smush-placeholder-aspect-ratio: 628\/132;\" \/><\/p>\n<p>At last our trend chart is all set up. \u00a0 Press &#8220;Apply&#8221; and &#8220;OK&#8221;. \u00a0 \u00a0Next, we need to click the &#8220;Run&#8221; button on your trend chart.<\/p>\n<h2>Run your Trend<\/h2>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1017 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/TrendRun.png\" alt=\"Trend Run\" width=\"271\" height=\"118\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/TrendRun.png 271w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/TrendRun-270x118.png 270w\" data-sizes=\"(max-width: 271px) 100vw, 271px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 271px; --smush-placeholder-aspect-ratio: 271\/118;\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>Finally, \u00a0you will see your pen track the PipePressure tag over time.<\/p>\n<p>Click anywhere on the chart, and a value bar will appear. \u00a0 This value bar tells you the value of the pen at that moment in time. \u00a0 In this instance, we can see that we have an occasional pressure failure of around 150 psi.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1019 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/PressureFailure.png\" alt=\"Pressure failure\" width=\"564\" height=\"433\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/PressureFailure.png 564w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/PressureFailure-300x230.png 300w\" data-sizes=\"(max-width: 564px) 100vw, 564px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 564px; --smush-placeholder-aspect-ratio: 564\/433;\" \/><\/p>\n<p>Be aware that if you click and drag your mouse across the screen, you will draw a box on the chart. \u00a0 When you release your mouse button, the chart will be zoomed in. \u00a0To get out of zoom mode, right-click the chart, and choose &#8220;Undo Zoom&#8221;. \u00a0 You may also need to &#8220;unpause&#8221; your chart. \u00a0The Pause\/scroll button is at the bottom of your trend chart.<\/p>\n<p>For more information, please visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/controllogix\/\">ControlLogix Post<\/a> page!<\/p>\n<p>&nbsp;<\/p>\n<p>&#8212; Ricky Bryce<\/p>\n<p>&nbsp;<\/p>\n<div id=\"bryce-3774616484\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to ControlLogix Trending ControlLogix Trending will track values over time. \u00a0 Most commonly, you will use trending on analog values, but it can be used to track digital (discrete on\/off) signals as well. \u00a0Think of trending as a &#8220;software chart recorder&#8221;. In this example, we will use trending to track a Pipe Pressure over <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":1019,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[11,46],"class_list":{"0":"post-1009","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-controllogix","8":"tag-controllogix","9":"tag-trending","10":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Setting up and adjusting a trend chart in Studio 5000<\/title>\n<meta name=\"description\" content=\"How to set up and configure the X Axis and Y Axis on a trend chart using Studio 5000. This allows you to track tags over time.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Setting up and adjusting a trend chart in Studio 5000\" \/>\n<meta property=\"og:description\" content=\"How to set up and configure the X Axis and Y Axis on a trend chart using Studio 5000. This allows you to track tags over time.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2017-06-12T20:23:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/PressureFailure.png\" \/>\n\t<meta property=\"og:image:width\" content=\"564\" \/>\n\t<meta property=\"og:image:height\" content=\"433\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"ControlLogix Trending\",\"datePublished\":\"2017-06-12T20:23:04+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/\"},\"wordCount\":617,\"commentCount\":5,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/06\\\/PressureFailure.png\",\"keywords\":[\"ControlLogix\",\"Trending\"],\"articleSection\":[\"ControlLogix\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/\",\"name\":\"Setting up and adjusting a trend chart in Studio 5000\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/06\\\/PressureFailure.png\",\"datePublished\":\"2017-06-12T20:23:04+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"How to set up and configure the X Axis and Y Axis on a trend chart using Studio 5000. This allows you to track tags over time.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/06\\\/PressureFailure.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/06\\\/PressureFailure.png\",\"width\":564,\"height\":433,\"caption\":\"Pressure failure\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/06\\\/12\\\/controllogix-trending\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ControlLogix Trending\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Setting up and adjusting a trend chart in Studio 5000","description":"How to set up and configure the X Axis and Y Axis on a trend chart using Studio 5000. This allows you to track tags over time.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/","og_locale":"en_US","og_type":"article","og_title":"Setting up and adjusting a trend chart in Studio 5000","og_description":"How to set up and configure the X Axis and Y Axis on a trend chart using Studio 5000. This allows you to track tags over time.","og_url":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2017-06-12T20:23:04+00:00","og_image":[{"width":564,"height":433,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/PressureFailure.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"ControlLogix Trending","datePublished":"2017-06-12T20:23:04+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/"},"wordCount":617,"commentCount":5,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/PressureFailure.png","keywords":["ControlLogix","Trending"],"articleSection":["ControlLogix"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/","url":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/","name":"Setting up and adjusting a trend chart in Studio 5000","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/PressureFailure.png","datePublished":"2017-06-12T20:23:04+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"How to set up and configure the X Axis and Y Axis on a trend chart using Studio 5000. This allows you to track tags over time.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/PressureFailure.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/06\/PressureFailure.png","width":564,"height":433,"caption":"Pressure failure"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-trending\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"ControlLogix Trending"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/1009","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=1009"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/1009\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/1019"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=1009"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=1009"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=1009"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}