{"id":10496,"date":"2022-03-10T13:25:18","date_gmt":"2022-03-10T13:25:18","guid":{"rendered":"https:\/\/bryceautomation.com\/?p=10496"},"modified":"2022-03-10T13:42:27","modified_gmt":"2022-03-10T13:42:27","slug":"converting-rsview32-to-factorytalk","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/","title":{"rendered":"Converting RSView32 to FactoryTalk"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Introduction to Converting RSView32 to FactoryTalk<\/h3>\n\n\n\n<p>Before Converting RSView32 to FactoryTalk we will need to install some software.  First of all, I have RSView32 on a Windows XP computer.  This is a 32 bit machine.  Secondly, I have FactoryTalk View SE version 12 on a 64 bit computer.  Thirdly, I am installing FactoryTalk View version 7 on the Windows XP Machine.  The reason I am installing FactoryTalk View on the Windows XP machine is so I have the Legacy Tag Database Converter tool.  If you don&#8217;t want to install FactoryTalk View on the Windows XP machine, you can probably download this tool separately.<\/p><div id=\"bryce-4271515519\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<p>At this point, we&#8217;ll be Converting RSView32 to FactoryTalk View SE.  We&#8217;ll go through several steps to accomplish this.  In this case, we&#8217;ll be using a Network Station setup.  This is one of the packages available from Rockwell.  You can also migrate projects to Local Station, and Network Distributed as well.<\/p>\n\n\n\n<p><strong><em>After your conversion, be sure your project is working properly before depending on the implementation in any way!<\/em><\/strong><\/p>\n\n\n\n<h3 class=\"wp-block-heading\">About the RSView32 Project<\/h3>\n\n\n\n<p>We&#8217;re going to keep this simple.  My RSView Application simply has two tags.  One standard HMI Tag, and an Alarm Tag.  Additionally, I have a display screen which utilizes the HMI Tag.  This allows us to walk through the steps involved in converting most any application.<\/p>\n\n\n\n<p>Be sure you have a backup of your RSView32 project before you continue!<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-51.png\" alt=\"\" class=\"wp-image-10498 lazyload\" width=\"402\" height=\"307\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-51.png 538w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-51-300x229.png 300w\" data-sizes=\"(max-width: 402px) 100vw, 402px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 402px; --smush-placeholder-aspect-ratio: 402\/307;\" \/><\/figure>\n\n\n\n<p>We just have a simple display called &#8220;Main&#8221;.  This display is the initial graphic in RSView32.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"235\" height=\"218\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-52.png\" alt=\"\" class=\"wp-image-10499 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 235px; --smush-placeholder-aspect-ratio: 235\/218;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Legacy Tag Database Conversion Utility<\/h3>\n\n\n\n<p>We will need to run the Legacy Tag Database conversion utility twice.  First, we&#8217;ll run this on the 32 bit machine to Export the Legacy tag database.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-53.png\" alt=\"\" class=\"wp-image-10501 lazyload\" width=\"320\" height=\"96\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-53.png 410w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-53-300x90.png 300w\" data-sizes=\"(max-width: 320px) 100vw, 320px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 320px; --smush-placeholder-aspect-ratio: 320\/96;\" \/><\/figure>\n\n\n\n<p>Click Next, and choose RSView32.  Browse for your RSView32 project.  I like to click the box to search the sub folders.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-54.png\" alt=\"\" class=\"wp-image-10502 lazyload\" width=\"315\" height=\"282\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-54.png 423w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-54-300x269.png 300w\" data-sizes=\"(max-width: 315px) 100vw, 315px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 315px; --smush-placeholder-aspect-ratio: 315\/282;\" \/><\/figure>\n\n\n\n<p>Click Next.  You should see the RSV file for your project.  Click Next, then Finish.<\/p>\n\n\n\n<p>After that we&#8217;ll copy the entire RSview32 project folder over to your 64 bit computer.  Run the Legacy Tag Database conversion utility again.  This time, choose &#8220;Create FactoryTalk View Database in New Format&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-55.png\" alt=\"\" class=\"wp-image-10504 lazyload\" width=\"376\" height=\"127\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-55.png 391w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-55-300x101.png 300w\" data-sizes=\"(max-width: 376px) 100vw, 376px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 376px; --smush-placeholder-aspect-ratio: 376\/127;\" \/><\/figure>\n\n\n\n<p>Click Next, and browse for your project on the 64 Bit macine.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-56.png\" alt=\"\" class=\"wp-image-10505 lazyload\" width=\"375\" height=\"266\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-56.png 488w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-56-300x213.png 300w\" data-sizes=\"(max-width: 375px) 100vw, 375px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 375px; --smush-placeholder-aspect-ratio: 375\/266;\" \/><\/figure>\n\n\n\n<p>You will see your RSView32 project.  Hit Finish.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">At last, we&#8217;ll be Converting RSView32 to FactoryTalk<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">Create a new Project<\/h4>\n\n\n\n<p>Before we begin, let&#8217;s open Factory Talk View SE.  We&#8217;ll create a new &#8220;Network Station&#8221; Application.<\/p>\n\n\n\n<p>Note:  If you choose Local Station, you will have an &#8220;IMPORT&#8221; button when you create the file. Use that to import your HMI project.  In this case, though, we have a &#8220;Network Station&#8221;.  The procedure is very similar though.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"479\" height=\"254\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-57.png\" alt=\"\" class=\"wp-image-10507 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-57.png 479w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-57-300x159.png 300w\" data-sizes=\"(max-width: 479px) 100vw, 479px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 479px; --smush-placeholder-aspect-ratio: 479\/254;\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"390\" height=\"157\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-58.png\" alt=\"\" class=\"wp-image-10508 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-58.png 390w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-58-300x121.png 300w\" data-sizes=\"(max-width: 390px) 100vw, 390px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 390px; --smush-placeholder-aspect-ratio: 390\/157;\" \/><\/figure>\n\n\n\n<p>Let&#8217;s create a new Area.  <\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"310\" height=\"182\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-60.png\" alt=\"\" class=\"wp-image-10510 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-60.png 310w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-60-300x176.png 300w\" data-sizes=\"(max-width: 310px) 100vw, 310px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 310px; --smush-placeholder-aspect-ratio: 310\/182;\" \/><\/figure>\n\n\n\n<p>We&#8217;ll just call this area &#8220;Area01&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"202\" height=\"130\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-61.png\" alt=\"\" class=\"wp-image-10511 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 202px; --smush-placeholder-aspect-ratio: 202\/130;\" \/><\/figure>\n\n\n\n<p>Next, right click Area01 in your explorer tree, and add an HMI Server.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"477\" height=\"208\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-62.png\" alt=\"\" class=\"wp-image-10512 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-62.png 477w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-62-300x131.png 300w\" data-sizes=\"(max-width: 477px) 100vw, 477px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 477px; --smush-placeholder-aspect-ratio: 477\/208;\" \/><\/figure>\n\n\n\n<p>Choose to Import a Project.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"295\" height=\"231\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-64.png\" alt=\"\" class=\"wp-image-10514 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 295px; --smush-placeholder-aspect-ratio: 295\/231;\" \/><\/figure>\n\n\n\n<p>At this point, browse to your .RSV file that we copied from the 32 bit machine.  Keep in mind that the tags in this folder are already converted.   The exception is the alarm tags, which we&#8217;ll deal with a little later.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"627\" height=\"206\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-65.png\" alt=\"\" class=\"wp-image-10515 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-65.png 627w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-65-300x99.png 300w\" data-sizes=\"(max-width: 627px) 100vw, 627px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 627px; --smush-placeholder-aspect-ratio: 627\/206;\" \/><\/figure>\n\n\n\n<p>Name your project, then add a description if you wish.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"361\" height=\"131\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-66.png\" alt=\"\" class=\"wp-image-10516 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-66.png 361w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-66-300x109.png 300w\" data-sizes=\"(max-width: 361px) 100vw, 361px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 361px; --smush-placeholder-aspect-ratio: 361\/131;\" \/><\/figure>\n\n\n\n<p>Finally, click &#8220;Finish&#8221; to complete the Import.<\/p>\n\n\n\n<p>At this point, we get this message:<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"562\" height=\"145\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-67.png\" alt=\"\" class=\"wp-image-10517 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-67.png 562w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-67-300x77.png 300w\" data-sizes=\"(max-width: 562px) 100vw, 562px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 562px; --smush-placeholder-aspect-ratio: 562\/145;\" \/><\/figure>\n\n\n\n<p>This means we need to run the FactoryTalk Alarm Migration tool.  This should already be on your computer.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Run the FactoryTalk Alarm Migration Tool<\/h3>\n\n\n\n<p>It&#8217;s important to realize that the Alarm Migration tool is looking to convert the alarm tags that are already in your FactoryTalk View SE Application.  This means that we must browse for the .SED file.  Not the RSV File.  In Windows 10 search bar, just type &#8220;Alarm Migration&#8221;.  Launch the utility.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"504\" height=\"191\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-68.png\" alt=\"\" class=\"wp-image-10518 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-68.png 504w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-68-300x114.png 300w\" data-sizes=\"(max-width: 504px) 100vw, 504px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 504px; --smush-placeholder-aspect-ratio: 504\/191;\" \/><\/figure>\n\n\n\n<p>We&#8217;ll choose the first option.  This is to export the tags in XML Format.<\/p>\n\n\n\n<p>Browse to your FactoryTalk View HMI project.  The default path will get you close.  Just choose the folder of the project you just created when performing the import.  You will find the .SED file in that folder.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"645\" height=\"151\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-69.png\" alt=\"\" class=\"wp-image-10519 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-69.png 645w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-69-300x70.png 300w\" data-sizes=\"(max-width: 645px) 100vw, 645px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 645px; --smush-placeholder-aspect-ratio: 645\/151;\" \/><\/figure>\n\n\n\n<p>Click &#8220;Finish&#8221;.  You can view the file contents if you wish to ensure your tags are in the file.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Create the Alarm and Event Server \/ Import your Tags<\/h3>\n\n\n\n<p>At this point we need to add an Alarm and Event server into our project.  After that, we&#8217;ll import the Alarm tags.  Remember, we will be importing the XML file that we exported using the FactoryTalk Alarm Migration tool.<\/p>\n\n\n\n<p>At this time, right click &#8220;Area01&#8221;, and add a new Alarm and Event Server.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"586\" height=\"324\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-70.png\" alt=\"\" class=\"wp-image-10520 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-70.png 586w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-70-300x166.png 300w\" data-sizes=\"(max-width: 586px) 100vw, 586px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 586px; --smush-placeholder-aspect-ratio: 586\/324;\" \/><\/figure>\n\n\n\n<p>Name your server.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"301\" height=\"146\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-71.png\" alt=\"\" class=\"wp-image-10521 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 301px; --smush-placeholder-aspect-ratio: 301\/146;\" \/><\/figure>\n\n\n\n<p>Go to &#8220;Priorities and History&#8221;.  In this case, I&#8217;ll enable priorities.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"395\" height=\"300\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-72.png\" alt=\"\" class=\"wp-image-10522 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-72.png 395w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-72-300x228.png 300w\" data-sizes=\"(max-width: 395px) 100vw, 395px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 395px; --smush-placeholder-aspect-ratio: 395\/300;\" \/><\/figure>\n\n\n\n<p>Click OK.<\/p>\n\n\n\n<p>At this point, are ready to import the tags.<\/p>\n\n\n\n<p>Right click your alarm server, and choose &#8220;Import and Export&#8221;.<\/p>\n\n\n\n<p>Choose to Import in the same format that you exported from.  In this case, it&#8217;s XML.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"346\" height=\"239\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-73.png\" alt=\"\" class=\"wp-image-10523 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-73.png 346w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-73-300x207.png 300w\" data-sizes=\"(max-width: 346px) 100vw, 346px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 346px; --smush-placeholder-aspect-ratio: 346\/239;\" \/><\/figure>\n\n\n\n<p>By default this exported to C:\\Users\\Public Documents\\RSView Enterprise\\SE\\HMI Projects\\YourNewAEServer\\   In this folder, you will find the XML file that we exported earlier.  I&#8217;ll just choose to update the existing tags, since there are none yet anyway.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"575\" height=\"175\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-74.png\" alt=\"\" class=\"wp-image-10524 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-74.png 575w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-74-300x91.png 300w\" data-sizes=\"(max-width: 575px) 100vw, 575px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 575px; --smush-placeholder-aspect-ratio: 575\/175;\" \/><\/figure>\n\n\n\n<p>Click &#8220;Finish&#8221;.<\/p>\n\n\n\n<p>At this point, your alarms, displays, events, derived tags, macros, etc, should be in your project.   You can browse through your project to verify this.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"238\" height=\"194\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-75.png\" alt=\"\" class=\"wp-image-10525 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 238px; --smush-placeholder-aspect-ratio: 238\/194;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Set up FactoryTalk Linx<\/h3>\n\n\n\n<p>Our next step is to set up communication.  Keep in mind that the name of our shortcut should be the same as the Node name in RSView32.  That way, you shouldn&#8217;t have to change many objects on your displays.  In this case, the node name was &#8220;PLC&#8221;.  Therefore, that will be the name of our shortcut.<\/p>\n\n\n\n<p>Right click Area01, and add FactoryTalk Linx as your communication server.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"718\" height=\"188\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-76.png\" alt=\"\" class=\"wp-image-10526 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-76.png 718w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-76-300x79.png 300w\" data-sizes=\"(max-width: 718px) 100vw, 718px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 718px; --smush-placeholder-aspect-ratio: 718\/188;\" \/><\/figure>\n\n\n\n<p>Under &#8220;Alarms and Events&#8221;, I&#8217;ll enable priorities.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"371\" height=\"317\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-77.png\" alt=\"\" class=\"wp-image-10527 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-77.png 371w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-77-300x256.png 300w\" data-sizes=\"(max-width: 371px) 100vw, 371px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 371px; --smush-placeholder-aspect-ratio: 371\/317;\" \/><\/figure>\n\n\n\n<p>Under FactoryTalk Linx, we&#8217;ll go to &#8220;Communication Setup&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"222\" height=\"105\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-78.png\" alt=\"\" class=\"wp-image-10528 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 222px; --smush-placeholder-aspect-ratio: 222\/105;\" \/><\/figure>\n\n\n\n<p>Add a Shortcut.  The name in this case is PLC.  Simply add whatever nodes were in RSView32.  You can add more than one.  Be sure the name of your shortcut and the path to your processor are highlighted at the same time.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"789\" height=\"358\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-79.png\" alt=\"\" class=\"wp-image-10529 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-79.png 789w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-79-300x136.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-79-768x348.png 768w\" data-sizes=\"(max-width: 789px) 100vw, 789px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 789px; --smush-placeholder-aspect-ratio: 789\/358;\" \/><\/figure>\n\n\n\n<p>Be sure to hit &#8220;Apply&#8221;.  If you do not hit &#8220;Apply&#8221;, your changes will not likely be saved.  The apply button is up where your add button was.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"205\" height=\"92\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-80.png\" alt=\"\" class=\"wp-image-10530 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 205px; --smush-placeholder-aspect-ratio: 205\/92;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Create your Startup Macro<\/h3>\n\n\n\n<p>In RSView32, we had a green startup flag.  You could check whatever services you needed at startup.  This included Alarms, Derived Tags, Events, Data Logs, etc.  We don&#8217;t have that in FactoryTalk View.  <\/p>\n\n\n\n<p>Obviously, to add a startup Macro, we right-click &#8220;Macros&#8221; and create a new Macro.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"396\" height=\"112\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-81.png\" alt=\"\" class=\"wp-image-10532 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-81.png 396w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-81-300x85.png 300w\" data-sizes=\"(max-width: 396px) 100vw, 396px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 396px; --smush-placeholder-aspect-ratio: 396\/112;\" \/><\/figure>\n\n\n\n<p>Double click the editor to bring up the command wizard.  Enter any commands that you need.  Here are some examples.  Don&#8217;t forget to declare an initial display as well.  That will save you from having to enter one on the client utility later on.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"316\" height=\"232\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-82.png\" alt=\"\" class=\"wp-image-10534 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-82.png 316w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-82-300x220.png 300w\" data-sizes=\"(max-width: 316px) 100vw, 316px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 316px; --smush-placeholder-aspect-ratio: 316\/232;\" \/><\/figure>\n\n\n\n<p>Save your macros as &#8220;Startup&#8221;<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"123\" height=\"61\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-83.png\" alt=\"\" class=\"wp-image-10536 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 123px; --smush-placeholder-aspect-ratio: 123\/61;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Launch the Client Utility<\/h3>\n\n\n\n<p>Finally, we are ready to create the client file.  The client file is simply a file that the operator opens to run the FactoryTalk View Project.  This client file contains the startup configuration.  It also contains other configurations such as a timeout for logging out of FactoryTalk View.<\/p>\n\n\n\n<p>Go to Tools | Launch SE Client.  Another option is to simply click the icon on the toolbar.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"415\" height=\"208\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-84.png\" alt=\"\" class=\"wp-image-10537 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-84.png 415w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-84-300x150.png 300w\" data-sizes=\"(max-width: 415px) 100vw, 415px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 415px; --smush-placeholder-aspect-ratio: 415\/208;\" \/><\/figure>\n\n\n\n<p>Create a new FactoryTalk Client Configuration file.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"579\" height=\"110\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-85.png\" alt=\"\" class=\"wp-image-10538 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-85.png 579w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-85-300x57.png 300w\" data-sizes=\"(max-width: 579px) 100vw, 579px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 579px; --smush-placeholder-aspect-ratio: 579\/110;\" \/><\/figure>\n\n\n\n<p>We&#8217;ll just leave the default name of &#8220;ClientFile&#8221; for now.  Hit Contrinue.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img decoding=\"async\" width=\"911\" height=\"137\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-86.png\" alt=\"\" class=\"wp-image-10539 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-86.png 911w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-86-300x45.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-86-768x115.png 768w\" data-sizes=\"(max-width: 911px) 100vw, 911px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 911px; --smush-placeholder-aspect-ratio: 911\/137;\" \/><\/figure>\n\n\n\n<p>In this case, we have a network station.  Choose your file.  Don&#8217;t forget to select your startup macro.  Hit Save then Run.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img decoding=\"async\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-87.png\" alt=\"\" class=\"wp-image-10540 lazyload\" width=\"525\" height=\"339\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-87.png 778w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-87-300x194.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-87-768x496.png 768w\" data-sizes=\"(max-width: 525px) 100vw, 525px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 525px; --smush-placeholder-aspect-ratio: 525\/339;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Summary<\/h3>\n\n\n\n<p>In Short, Converting RSView32 to FactoryTalk is not that difficult.  Simply export your tags on the 32 bit bit machine, and create them on your 64 bit machine.  Use the legacy tag converter for this.  After that, import your HMI Server.  Then, run another utility to migrate your alarms.  Import your alarms.  Create your communications path in FactoryTalk View, and a Startup Macro.  Launch the client utility, and your conversion is complete.  However, if you are migrating to ControlLogix from PLC-5 at the same time, you will have some tag names to convert as well, which would be a different process.<\/p>\n\n\n\n<p>For more information, visit the<a href=\"https:\/\/bryceautomation.com\/index.php\/category\/factorytalk-view-se\/\"> FactoryTalk View Category Page!<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-3341098100\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to Converting RSView32 to FactoryTalk Before Converting RSView32 to FactoryTalk we will need to install some software. First of all, I have RSView32 on a Windows XP computer. This is a 32 bit machine. Secondly, I have FactoryTalk View SE version 12 on a 64 bit computer. Thirdly, I am installing FactoryTalk View version <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":10514,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[205],"tags":[278,462,460],"class_list":{"0":"post-10496","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-factorytalk-view-se","8":"tag-conversion","9":"tag-migration","10":"tag-rsview32","11":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Converting RSView32 to FactoryTalk - Bryce Automation<\/title>\n<meta name=\"description\" content=\"Converting RSView32 to FactoryTalk View SE. We&#039;ll be migrating a project from a 32 bit machine to a 64 bit machine.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Converting RSView32 to FactoryTalk - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"Converting RSView32 to FactoryTalk View SE. We&#039;ll be migrating a project from a 32 bit machine to a 64 bit machine.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2022-03-10T13:25:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-03-10T13:42:27+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-64.png\" \/>\n\t<meta property=\"og:image:width\" content=\"295\" \/>\n\t<meta property=\"og:image:height\" content=\"231\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"Converting RSView32 to FactoryTalk\",\"datePublished\":\"2022-03-10T13:25:18+00:00\",\"dateModified\":\"2022-03-10T13:42:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/\"},\"wordCount\":1359,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/image-64.png\",\"keywords\":[\"conversion\",\"migration\",\"RSView32\"],\"articleSection\":[\"FactoryTalk View SE\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/\",\"name\":\"Converting RSView32 to FactoryTalk - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/image-64.png\",\"datePublished\":\"2022-03-10T13:25:18+00:00\",\"dateModified\":\"2022-03-10T13:42:27+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"Converting RSView32 to FactoryTalk View SE. We'll be migrating a project from a 32 bit machine to a 64 bit machine.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/image-64.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2022\\\/03\\\/image-64.png\",\"width\":295,\"height\":231,\"caption\":\"RSView32 Conversion Import\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2022\\\/03\\\/10\\\/converting-rsview32-to-factorytalk\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Converting RSView32 to FactoryTalk\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Converting RSView32 to FactoryTalk - Bryce Automation","description":"Converting RSView32 to FactoryTalk View SE. We'll be migrating a project from a 32 bit machine to a 64 bit machine.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/","og_locale":"en_US","og_type":"article","og_title":"Converting RSView32 to FactoryTalk - Bryce Automation","og_description":"Converting RSView32 to FactoryTalk View SE. We'll be migrating a project from a 32 bit machine to a 64 bit machine.","og_url":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2022-03-10T13:25:18+00:00","article_modified_time":"2022-03-10T13:42:27+00:00","og_image":[{"width":295,"height":231,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-64.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"Converting RSView32 to FactoryTalk","datePublished":"2022-03-10T13:25:18+00:00","dateModified":"2022-03-10T13:42:27+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/"},"wordCount":1359,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-64.png","keywords":["conversion","migration","RSView32"],"articleSection":["FactoryTalk View SE"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/","url":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/","name":"Converting RSView32 to FactoryTalk - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-64.png","datePublished":"2022-03-10T13:25:18+00:00","dateModified":"2022-03-10T13:42:27+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"Converting RSView32 to FactoryTalk View SE. We'll be migrating a project from a 32 bit machine to a 64 bit machine.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-64.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2022\/03\/image-64.png","width":295,"height":231,"caption":"RSView32 Conversion Import"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2022\/03\/10\/converting-rsview32-to-factorytalk\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"Converting RSView32 to FactoryTalk"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/10496","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=10496"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/10496\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/10514"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=10496"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=10496"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=10496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}