{"id":1073,"date":"2017-09-13T16:25:43","date_gmt":"2017-09-13T16:25:43","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=1073"},"modified":"2022-07-12T20:10:37","modified_gmt":"2022-07-12T20:10:37","slug":"factorytalk-view-project","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/","title":{"rendered":"Creating a FactoryTalk View Project"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Introduction to Creating a FactoryTalk View ME Project<\/h2>\n\n\n\n<p>When creating a FactoryTalk View project, there is some information we will first need to gather. &nbsp;You will need to know the model of your PanelView Plus terminal (such as Panelview 700). &nbsp; We also need to know the IP address of the chassis that we wish to connect to. &nbsp; If you have an Ethernet module in the chassis, this information will probably be scrolling across the front of the Ethernet module. &nbsp;If your Ethernet module is displaying &#8220;BootP&#8221;, then use the <a href=\"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/bootp-server\/\">BootP server<\/a> utility to assign an IP address. &nbsp; Another method of assigning an IP address is by using the <a href=\"https:\/\/bryceautomation.com\/index.php\/2017\/06\/07\/assigning-ip-address-rslinx\/\">RSWho Screen in RSLinx<\/a>. &nbsp; &nbsp;Newer Ethernet Modules for ControlLogix also have on-board switches if you choose to use that method.<\/p><div id=\"bryce-3703888659\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<p>Next, we will Open FactoryTalk View ME Studio Machine Edition. &nbsp; To develop a project, we will use &#8220;Studio&#8221;. &nbsp; We don&#8217;t want to use &#8220;Station&#8221; yet, because that is for runtime only after our project is developed.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"101\" height=\"97\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/FTStudioIcon.png\" alt=\"FactoryTalk View Studio Icon\" class=\"wp-image-1074 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 101px; --smush-placeholder-aspect-ratio: 101\/97;\" \/><\/figure>\n<\/div>\n\n\n<p>If you do not have a shortcut on your desktop, you can access Factory Talk View Studio by going to Start | All Programs | Rockwell Software | FactoryTalk View.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Setting up your new project.<\/h2>\n\n\n\n<p>Once FactoryTalk View has been launched, let&#8217;s create a new project. &nbsp; &nbsp;Please be patient when clicking the &#8220;New&#8221; tab. &nbsp; This could take a few seconds to switch to the &#8220;New&#8221; tab.<\/p>\n\n\n\n<p>Be sure to populate the name of your project, and the panelview type. &nbsp;Then press &#8220;Create&#8221;.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"438\" height=\"402\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/mytestproject.png\" alt=\"Factory Talk Create Project\" class=\"wp-image-1075 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/mytestproject.png 438w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/mytestproject-300x275.png 300w\" data-sizes=\"(max-width: 438px) 100vw, 438px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 438px; --smush-placeholder-aspect-ratio: 438\/402;\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Communication<\/h2>\n\n\n\n<p>Next, we will configure communication to the processor(s) that we wish to read or write to. &nbsp; &nbsp;at the bottom of the explorer tree, we need to double click &#8220;Communciation Setup&#8221; under &#8220;RSLinx Enterprise&#8221;.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"178\" height=\"85\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/rslinxenterprise.png\" alt=\"RSLinx Enterprise Comms Setup\" class=\"wp-image-1076 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 178px; --smush-placeholder-aspect-ratio: 178\/85;\" \/><\/figure>\n<\/div>\n\n\n<p>Here, we will be creating a &#8220;shortcut&#8221;. &nbsp; &nbsp;The purpose of this shortcut is to create a name that is associated with the path of your processor. &nbsp;Anytime we reference this shortcut, FactoryTalk View ME will know the path to your processor.<\/p>\n\n\n\n<p>Let&#8217;s create a new configuration:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"436\" height=\"344\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/createnewconfiguration.png\" alt=\"CreateNewConfig\" class=\"wp-image-1077 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/createnewconfiguration.png 436w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/createnewconfiguration-300x237.png 300w\" data-sizes=\"(max-width: 436px) 100vw, 436px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 436px; --smush-placeholder-aspect-ratio: 436\/344;\" \/><\/figure>\n<\/div>\n\n\n<p>After, you press finish, we will click &#8220;Add&#8221; to add a new shortcut.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"646\" height=\"254\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/addshortcut.png\" alt=\"Add Shortcut\" class=\"wp-image-1078 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/addshortcut.png 646w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/addshortcut-300x118.png 300w\" data-sizes=\"(max-width: 646px) 100vw, 646px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 646px; --smush-placeholder-aspect-ratio: 646\/254;\" \/><\/figure>\n<\/div>\n\n\n<p>Next, name your shortcut, and specify the path of your processor.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"648\" height=\"380\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/associatepath.png\" alt=\"AssociatePath\" class=\"wp-image-1079 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/associatepath.png 648w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/associatepath-300x176.png 300w\" data-sizes=\"(max-width: 648px) 100vw, 648px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 648px; --smush-placeholder-aspect-ratio: 648\/380;\" \/><\/figure>\n<\/div>\n\n\n<p>Be sure to click &#8220;Apply&#8221;<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"216\" height=\"106\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/commsapply.png\" alt=\"Comms Apply\" class=\"wp-image-1080 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 216px; --smush-placeholder-aspect-ratio: 216\/106;\" \/><\/figure>\n<\/div>\n\n\n<p>If your PanelView Terminal is running on Ethernet, and it&#8217;s on the same network as your laptop, then copy the shortcut from Design (Local) to Runtime (Target). &nbsp; &nbsp;The Design path is what you use to test your project as it&#8217;s being designed on your PC. &nbsp; The Runtime path is what the Panelview will use after you download your project to the Panelview Plus Terminal.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"337\" height=\"75\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/copytoruntime.png\" alt=\"Copy To Runtime\" class=\"wp-image-1081 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/copytoruntime.png 337w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/copytoruntime-300x67.png 300w\" data-sizes=\"(max-width: 337px) 100vw, 337px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 337px; --smush-placeholder-aspect-ratio: 337\/75;\" \/><\/figure>\n<\/div>\n\n\n<p>Press OK, and your communication is complete. &nbsp; You are ready to continue to the next document to begin developing display screens, and adding objects.<\/p>\n\n\n\n<p>Next learn about <a href=\"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/\">navigating between display screens!<\/a><\/p>\n\n\n\n<p>&#8212; &nbsp;Ricky Bryce<\/p>\n<div id=\"bryce-1690505484\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to Creating a FactoryTalk View ME Project When creating a FactoryTalk View project, there is some information we will first need to gather. &nbsp;You will need to know the model of your PanelView Plus terminal (such as Panelview 700). &nbsp; We also need to know the IP address of the chassis that we wish <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":1079,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[50],"tags":[51],"class_list":{"0":"post-1073","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-factorytalk-view-me","8":"tag-factorytalk-view","9":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Creating a FactoryTalk View project.<\/title>\n<meta name=\"description\" content=\"How to create a new project in FactoryTalk View Machine edition, choose your panelview terminal, and set up communication.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Creating a FactoryTalk View project.\" \/>\n<meta property=\"og:description\" content=\"How to create a new project in FactoryTalk View Machine edition, choose your panelview terminal, and set up communication.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2017-09-13T16:25:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-07-12T20:10:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/associatepath.png\" \/>\n\t<meta property=\"og:image:width\" content=\"648\" \/>\n\t<meta property=\"og:image:height\" content=\"380\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"Creating a FactoryTalk View Project\",\"datePublished\":\"2017-09-13T16:25:43+00:00\",\"dateModified\":\"2022-07-12T20:10:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/\"},\"wordCount\":483,\"commentCount\":7,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/associatepath.png\",\"keywords\":[\"FactoryTalk View\"],\"articleSection\":[\"FactoryTalk View ME\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/\",\"name\":\"Creating a FactoryTalk View project.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/associatepath.png\",\"datePublished\":\"2017-09-13T16:25:43+00:00\",\"dateModified\":\"2022-07-12T20:10:37+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"How to create a new project in FactoryTalk View Machine edition, choose your panelview terminal, and set up communication.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/associatepath.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/associatepath.png\",\"width\":648,\"height\":380,\"caption\":\"AssociatePath\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-project\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Creating a FactoryTalk View Project\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Creating a FactoryTalk View project.","description":"How to create a new project in FactoryTalk View Machine edition, choose your panelview terminal, and set up communication.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/","og_locale":"en_US","og_type":"article","og_title":"Creating a FactoryTalk View project.","og_description":"How to create a new project in FactoryTalk View Machine edition, choose your panelview terminal, and set up communication.","og_url":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2017-09-13T16:25:43+00:00","article_modified_time":"2022-07-12T20:10:37+00:00","og_image":[{"width":648,"height":380,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/associatepath.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"Creating a FactoryTalk View Project","datePublished":"2017-09-13T16:25:43+00:00","dateModified":"2022-07-12T20:10:37+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/"},"wordCount":483,"commentCount":7,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/associatepath.png","keywords":["FactoryTalk View"],"articleSection":["FactoryTalk View ME"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/","url":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/","name":"Creating a FactoryTalk View project.","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/associatepath.png","datePublished":"2017-09-13T16:25:43+00:00","dateModified":"2022-07-12T20:10:37+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"How to create a new project in FactoryTalk View Machine edition, choose your panelview terminal, and set up communication.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/associatepath.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/associatepath.png","width":648,"height":380,"caption":"AssociatePath"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-project\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"Creating a FactoryTalk View Project"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/1073","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=1073"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/1073\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/1079"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=1073"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=1073"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=1073"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}