{"id":1086,"date":"2017-09-13T17:55:17","date_gmt":"2017-09-13T17:55:17","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=1086"},"modified":"2022-03-13T15:02:34","modified_gmt":"2022-03-13T15:02:34","slug":"factorytalk-view-navigation","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/","title":{"rendered":"FactoryTalk View ME Navigation"},"content":{"rendered":"<h2>Introduction to FactoryTalk View ME Navigation<\/h2>\n<p>You&#8217;ve seen pictures of the old control centers with many panels that contained various gauges, push buttons, and other indicators. \u00a0 \u00a0In modern times, most of those devices can simply be placed on display screens. \u00a0 The operator needs to be able to quickly locate the control that he is looking for. \u00a0To accomplish this, you will usually organize your projects into different display screens. \u00a0In this document, we will discuss FactoryTalk View ME\u00a0 Navigation.\u00a0 If you are interested in how navigation works on FactoryTalk View SE, Look at the <a href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/17\/factorytalk-view-se-navigation\/\">FactoryTalk View SE Navigation document.<\/a><\/p><div id=\"bryce-605506011\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n<p>Once we add other display screens to the project, you will need to add navigation buttons. \u00a0 This allows the operator to move between different screens in your project. \u00a0Once the operator gets to a display screen, don&#8217;t forget to allow the operator to navigate back to the main screen.<\/p>\n<p>If you expand &#8220;Graphics&#8221; in the Explorer tree, and you will see that we have a main screen. \u00a0 \u00a0By default, this is the screen that will come up first when the project is first started. \u00a0 \u00a0You can change this screen under &#8220;Startup&#8221; in the explorer tree.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1087 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/displayscreens.png\" alt=\"Display screens\" width=\"171\" height=\"122\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 171px; --smush-placeholder-aspect-ratio: 171\/122;\" \/><\/p>\n<p>Next, let&#8217;s right-click &#8220;Displays&#8221; to add a new display screen. \u00a0 \u00a0We&#8217;ll add a text object to this screen called &#8220;Pump Control&#8221;. \u00a0 To access the Text object, click on Objects | Drawing | Text.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1088 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/gettextobject.png\" alt=\"Text Objects\" width=\"424\" height=\"156\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/gettextobject.png 424w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/gettextobject-300x110.png 300w\" data-sizes=\"(max-width: 424px) 100vw, 424px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 424px; --smush-placeholder-aspect-ratio: 424\/156;\" \/><\/p>\n<p>We will add the text to the top of your new display screen as shown. \u00a0 \u00a0You can change the size, color, fonts, etc&#8230; on the same screen that you are typing the text. \u00a0 \u00a0If you wish to change this later, you can access the properties screen by double clicking the object. \u00a0 Another way to access the properties screen is to right click the object and choose &#8220;Properties&#8221;.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1089 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/pumpcontrol.png\" alt=\"PumpControlScreen\" width=\"646\" height=\"184\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/pumpcontrol.png 646w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/pumpcontrol-300x85.png 300w\" data-sizes=\"(max-width: 646px) 100vw, 646px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 646px; --smush-placeholder-aspect-ratio: 646\/184;\" \/><\/p>\n<h2>Add Navigation Buttons<\/h2>\n<p>When the operator is on this screen, we need to have a way for the operator to navigate to the main screen. \u00a0 \u00a0Choose Objects | Display Navigation | Goto. \u00a0 Draw the &#8220;Goto&#8221; object on your display screen.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1090 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/addgoto-button.png\" alt=\"goto button\" width=\"434\" height=\"230\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/addgoto-button.png 434w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/addgoto-button-300x159.png 300w\" data-sizes=\"(max-width: 434px) 100vw, 434px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 434px; --smush-placeholder-aspect-ratio: 434\/230;\" \/><\/p>\n<p>On the &#8220;General Tab&#8221;, click the elipsis next to the Display text box. \u00a0 Configure this object as shown so when the operator presses the button, he will be taken to the main screen.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1091 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/generaldisplay.png\" alt=\"General Display\" width=\"442\" height=\"292\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/generaldisplay.png 442w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/generaldisplay-300x198.png 300w\" data-sizes=\"(max-width: 442px) 100vw, 442px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 442px; --smush-placeholder-aspect-ratio: 442\/292;\" \/><\/p>\n<p>Even though we told the object to go to the main screen once the button is pressed, we have not told the operator the purpose of the button. \u00a0 \u00a0We will do this under the &#8220;Label&#8221; tab.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1092 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/gotomain.png\" alt=\"Operator Label\" width=\"441\" height=\"176\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/gotomain.png 441w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/gotomain-300x120.png 300w\" data-sizes=\"(max-width: 441px) 100vw, 441px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 441px; --smush-placeholder-aspect-ratio: 441\/176;\" \/><\/p>\n<p>Your object should appear as shown:<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-1093 size-medium lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/pumpcontrolgogo-300x234.png\" alt=\"PumpControlGoto\" width=\"300\" height=\"234\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/pumpcontrolgogo-300x234.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/pumpcontrolgogo.png 650w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/234;\" \/><\/p>\n<p>Now, we will close the display with the X in the upper right hand corner, and save the screen as &#8220;Pump Control&#8221;<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1094 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/pumpcontrolsave.png\" alt=\"\" width=\"249\" height=\"106\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 249px; --smush-placeholder-aspect-ratio: 249\/106;\" \/><\/p>\n<p>We have now saved the Pump Control Screen. \u00a0 \u00a0Follow the same procedure to add a goto button to the Main screen. \u00a0 Set the display to &#8220;Pump Control&#8221; (on the general tab). \u00a0 The label for the operator will read &#8220;Go to Pump Control&#8221;. \u00a0Don&#8217;t forget to add text to the top of the main screen as shown. \u00a0 This tells the operator which screen he is currently on.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-1095 size-medium lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/Mainscreen-300x233.png\" alt=\"Main Screen\" width=\"300\" height=\"233\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/Mainscreen-300x233.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/Mainscreen.png 646w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/233;\" \/><\/p>\n<h2>Test your project<\/h2>\n<p>To test your navigation, press the &#8220;Test Application&#8221; button in the standard toolbar.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1096 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/testnavigation.png\" alt=\"Test Application\" width=\"493\" height=\"127\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/testnavigation.png 493w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/testnavigation-300x77.png 300w\" data-sizes=\"(max-width: 493px) 100vw, 493px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 493px; --smush-placeholder-aspect-ratio: 493\/127;\" \/><\/p>\n<p>Another way to add the navigation buttons is to copy them from one screen and past them on another, making basic changes to the properties of the object. \u00a0 \u00a0This helps to maintain a consistent size across all of your screens.<\/p>\n<p>If you have a Panelview Terminal without a touch screen (keypad only), you will want to relate the objects to function keys. \u00a0 If you need to establish this relationship, please include the function key in your object label for the operator. \u00a0 This tells the operator which function key to press to navigate between screens. \u00a0 To relate the objects to function keys, right click any blank area on the display, and choose &#8220;Key Assignments.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1097 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/KeyAssignments.png\" alt=\"Key Assignments\" width=\"460\" height=\"318\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/KeyAssignments.png 460w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/KeyAssignments-300x207.png 300w\" data-sizes=\"(max-width: 460px) 100vw, 460px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 460px; --smush-placeholder-aspect-ratio: 460\/318;\" \/><\/p>\n<p>Next, learn how to set up a <a href=\"https:\/\/bryceautomation.com\/index.php\/2017\/09\/14\/factorytalk-view-push-button-object\/\">FactoryTalk View Push Button object<\/a>!<\/p>\n<p>&#8212; \u00a0Ricky Bryce<\/p>\n<div id=\"bryce-1962080903\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to FactoryTalk View ME Navigation You&#8217;ve seen pictures of the old control centers with many panels that contained various gauges, push buttons, and other indicators. \u00a0 \u00a0In modern times, most of those devices can simply be placed on display screens. \u00a0 The operator needs to be able to quickly locate the control that he <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":1091,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[50],"tags":[52,51],"class_list":{"0":"post-1086","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-factorytalk-view-me","8":"tag-displays","9":"tag-factorytalk-view","10":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>FactoryTalk View ME Navigation -- Set up navigation between displays.<\/title>\n<meta name=\"description\" content=\"Creating displays within Factory Talk View, and establishing navigation between screens. We will also title the displays, and associate F keys if needed.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FactoryTalk View ME Navigation -- Set up navigation between displays.\" \/>\n<meta property=\"og:description\" content=\"Creating displays within Factory Talk View, and establishing navigation between screens. We will also title the displays, and associate F keys if needed.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2017-09-13T17:55:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-03-13T15:02:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/generaldisplay.png\" \/>\n\t<meta property=\"og:image:width\" content=\"442\" \/>\n\t<meta property=\"og:image:height\" content=\"292\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"FactoryTalk View ME Navigation\",\"datePublished\":\"2017-09-13T17:55:17+00:00\",\"dateModified\":\"2022-03-13T15:02:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/\"},\"wordCount\":646,\"commentCount\":2,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/generaldisplay.png\",\"keywords\":[\"Displays\",\"FactoryTalk View\"],\"articleSection\":[\"FactoryTalk View ME\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/\",\"name\":\"FactoryTalk View ME Navigation -- Set up navigation between displays.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/generaldisplay.png\",\"datePublished\":\"2017-09-13T17:55:17+00:00\",\"dateModified\":\"2022-03-13T15:02:34+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"Creating displays within Factory Talk View, and establishing navigation between screens. We will also title the displays, and associate F keys if needed.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/generaldisplay.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/09\\\/generaldisplay.png\",\"width\":442,\"height\":292,\"caption\":\"General Display\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/09\\\/13\\\/factorytalk-view-navigation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FactoryTalk View ME Navigation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FactoryTalk View ME Navigation -- Set up navigation between displays.","description":"Creating displays within Factory Talk View, and establishing navigation between screens. We will also title the displays, and associate F keys if needed.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/","og_locale":"en_US","og_type":"article","og_title":"FactoryTalk View ME Navigation -- Set up navigation between displays.","og_description":"Creating displays within Factory Talk View, and establishing navigation between screens. We will also title the displays, and associate F keys if needed.","og_url":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2017-09-13T17:55:17+00:00","article_modified_time":"2022-03-13T15:02:34+00:00","og_image":[{"width":442,"height":292,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/generaldisplay.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"FactoryTalk View ME Navigation","datePublished":"2017-09-13T17:55:17+00:00","dateModified":"2022-03-13T15:02:34+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/"},"wordCount":646,"commentCount":2,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/generaldisplay.png","keywords":["Displays","FactoryTalk View"],"articleSection":["FactoryTalk View ME"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/","url":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/","name":"FactoryTalk View ME Navigation -- Set up navigation between displays.","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/generaldisplay.png","datePublished":"2017-09-13T17:55:17+00:00","dateModified":"2022-03-13T15:02:34+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"Creating displays within Factory Talk View, and establishing navigation between screens. We will also title the displays, and associate F keys if needed.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/generaldisplay.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/09\/generaldisplay.png","width":442,"height":292,"caption":"General Display"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/09\/13\/factorytalk-view-navigation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"FactoryTalk View ME Navigation"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/1086","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=1086"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/1086\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/1091"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=1086"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=1086"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=1086"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}