{"id":1432,"date":"2017-11-08T12:31:37","date_gmt":"2017-11-08T12:31:37","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=1432"},"modified":"2017-11-08T12:43:54","modified_gmt":"2017-11-08T12:43:54","slug":"controllogix-flashers","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/","title":{"rendered":"ControlLogix Flashers"},"content":{"rendered":"<h2>Introduction to ControlLogix Flashers<\/h2>\n<p>ControlLogix flashers allow for an output to be energized and de-energized at a steady interval.\u00a0 \u00a0 For example, if we have an alarm horn, you can add a flasher bit in series with the output.\u00a0 \u00a0The alarm horn will then energize and de-energize at regular intervals.\u00a0 Subsequently, this will get the operator&#8217;s attention.<\/p><div id=\"bryce-339605010\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n<p>With this purpose in mind, we will discuss two different ways to generate a pulse.\u00a0 \u00a0First, we will use a simple self-running timer.\u00a0 \u00a0Secondly, we will use two timer to give us control of both the &#8220;ON&#8221; time, and the &#8220;OFF&#8221; time.\u00a0 \u00a0 Basically, this will give a &#8220;Strobe&#8221; effect.<\/p>\n<p>If you are not familiar with timers yet, please read up on <a href=\"https:\/\/bryceautomation.com\/index.php\/2017\/05\/30\/controllogix-timers\/\">this article<\/a> before you continue.<\/p>\n<h2>Self-Run Method<\/h2>\n<p>The self-running timer method is the most simple.\u00a0 \u00a0 In this situation, we will have just one timer that continues to reset itself every second.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1433 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/Selfrun.png\" alt=\"Self Running Timer\" width=\"453\" height=\"94\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/Selfrun.png 453w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/Selfrun-300x62.png 300w\" data-sizes=\"(max-width: 453px) 100vw, 453px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 453px; --smush-placeholder-aspect-ratio: 453\/94;\" \/><\/p>\n<p>When the accumulated value reaches 1000, the DN bit goes high.\u00a0 \u00a0 Obviously, the timer will then shut off.\u00a0 \u00a0When the time shuts off, the DN Bit goes low.\u00a0 \u00a0When this happens, the timer will start again.<\/p>\n<p>We will use a GRT (greater than) instruction to create the flasher bit.\u00a0 \u00a0 In this case, the flasher bit will be on for the last half of the second, and off for the first half of every second.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1434 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/GRT.png\" alt=\"GRT Flasher\" width=\"464\" height=\"113\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/GRT.png 464w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/GRT-300x73.png 300w\" data-sizes=\"(max-width: 464px) 100vw, 464px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 464px; --smush-placeholder-aspect-ratio: 464\/113;\" \/><\/p>\n<h2>Flip Flop method<\/h2>\n<p>Another method is to use two separate timers.\u00a0 \u00a0This gives us more control of the &#8220;ON&#8221; time, and the &#8220;OFF&#8221; Time.\u00a0 \u00a0 When the first timer finishes timing, the second timer will start.\u00a0 \u00a0When the second timer is finished timing, the first timer will no longer be enabled.\u00a0 \u00a0 At this time the first timer is no longer enabled, it&#8217;s DN bit goes false.\u00a0 \u00a0 In turn, the DN Bit for the second timer goes false.\u00a0 \u00a0 \u00a0When this happens, the first timer begins to run again, and the whole process starts all over!\u00a0 \u00a0That beings said, it&#8217;s a little more complicated than the Self-Run method.\u00a0 \u00a0By the same token, the logic shown is exactly how you would wire time delay relays to perform the same action!\u00a0 \u00a0Let&#8217;s look at the code.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-1435 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/flipflop.png\" alt=\"FlipFlop Timers\" width=\"448\" height=\"288\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/flipflop.png 448w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/flipflop-300x193.png 300w\" data-sizes=\"(max-width: 448px) 100vw, 448px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 448px; --smush-placeholder-aspect-ratio: 448\/288;\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>In either case, you can use the flasher bit in series with any output such as a strobe or alarm horn to get the operator&#8217;s attention!<\/p>\n<p>&nbsp;<\/p>\n<p>&#8212;\u00a0 Ricky Bryce<\/p>\n<p>&nbsp;<\/p>\n<div id=\"bryce-400292029\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to ControlLogix Flashers ControlLogix flashers allow for an output to be energized and de-energized at a steady interval.\u00a0 \u00a0 For example, if we have an alarm horn, you can add a flasher bit in series with the output.\u00a0 \u00a0The alarm horn will then energize and de-energize at regular intervals.\u00a0 Subsequently, this will get the <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":1435,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[11,95,26],"class_list":{"0":"post-1432","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-controllogix","8":"tag-controllogix","9":"tag-flashers","10":"tag-timers","11":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to write logic to flash a bit in the ControlLogix processor.<\/title>\n<meta name=\"description\" content=\"Flashing a bit in the ControlLogix processor. We will cover the Self-Running timer method, and the Flip Flop timing method.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to write logic to flash a bit in the ControlLogix processor.\" \/>\n<meta property=\"og:description\" content=\"Flashing a bit in the ControlLogix processor. We will cover the Self-Running timer method, and the Flip Flop timing method.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2017-11-08T12:31:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-11-08T12:43:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/flipflop.png\" \/>\n\t<meta property=\"og:image:width\" content=\"448\" \/>\n\t<meta property=\"og:image:height\" content=\"288\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"ControlLogix Flashers\",\"datePublished\":\"2017-11-08T12:31:37+00:00\",\"dateModified\":\"2017-11-08T12:43:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/\"},\"wordCount\":391,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/11\\\/flipflop.png\",\"keywords\":[\"ControlLogix\",\"Flashers\",\"timers\"],\"articleSection\":[\"ControlLogix\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/\",\"name\":\"How to write logic to flash a bit in the ControlLogix processor.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/11\\\/flipflop.png\",\"datePublished\":\"2017-11-08T12:31:37+00:00\",\"dateModified\":\"2017-11-08T12:43:54+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"Flashing a bit in the ControlLogix processor. We will cover the Self-Running timer method, and the Flip Flop timing method.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/11\\\/flipflop.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/11\\\/flipflop.png\",\"width\":448,\"height\":288,\"caption\":\"FlipFlop Timers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/11\\\/08\\\/controllogix-flashers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ControlLogix Flashers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to write logic to flash a bit in the ControlLogix processor.","description":"Flashing a bit in the ControlLogix processor. We will cover the Self-Running timer method, and the Flip Flop timing method.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/","og_locale":"en_US","og_type":"article","og_title":"How to write logic to flash a bit in the ControlLogix processor.","og_description":"Flashing a bit in the ControlLogix processor. We will cover the Self-Running timer method, and the Flip Flop timing method.","og_url":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2017-11-08T12:31:37+00:00","article_modified_time":"2017-11-08T12:43:54+00:00","og_image":[{"width":448,"height":288,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/flipflop.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"ControlLogix Flashers","datePublished":"2017-11-08T12:31:37+00:00","dateModified":"2017-11-08T12:43:54+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/"},"wordCount":391,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/flipflop.png","keywords":["ControlLogix","Flashers","timers"],"articleSection":["ControlLogix"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/","url":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/","name":"How to write logic to flash a bit in the ControlLogix processor.","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/flipflop.png","datePublished":"2017-11-08T12:31:37+00:00","dateModified":"2017-11-08T12:43:54+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"Flashing a bit in the ControlLogix processor. We will cover the Self-Running timer method, and the Flip Flop timing method.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/flipflop.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/11\/flipflop.png","width":448,"height":288,"caption":"FlipFlop Timers"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/11\/08\/controllogix-flashers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"ControlLogix Flashers"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/1432","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=1432"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/1432\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/1435"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=1432"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=1432"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=1432"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}