{"id":1786,"date":"2019-03-28T11:12:53","date_gmt":"2019-03-28T11:12:53","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=1786"},"modified":"2022-11-11T10:15:41","modified_gmt":"2022-11-11T10:15:41","slug":"slc-500-tof-instruction","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/","title":{"rendered":"SLC 500 Off Delay Timer"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Introduction to the SLC 500 Off Delay Timer<\/h2>\n\n\n\n<p>The SLC 500 Off Delay Timer (TOF) Delays the DN (Done) bit from shutting off.  Many people will find this as the most confusing type of timer.  Once you understand it&#8217;s operation, and relate it to a real process, however, its easy to use.<\/p><div id=\"bryce-1637225509\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<p>Examples of an the SLC 500 Off Delay Timer include a blower on the top of a motor.   The blower continues to keep the motor cool for a certain time after the main motor is shut off.<\/p>\n\n\n\n<p>Another example is a conveyor system.   When you shut down a conveyor system, you shut off the product being fed onto the conveyor.   Then, you may want the conveyor to run for a certain amount of time, before the belts actually stop.<\/p>\n\n\n\n<p>Another example is a blower, which is blowing a product through a pipe.  After you shut off the product feed into the line, the blower can run for a certain amount of time to blow the line clear.<\/p>\n\n\n\n<p>Each timer in your data files consume three words.  The first word is for the status bits of the timer.  The other two words are for the preset and accumulated values.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Timer Data Table (T4)<\/h2>\n\n\n\n<p>By default, the T4 data file is where the status of our timers are stored.   Think of this as a work space for timers to be able to operate.  If you open the T4 Data Table, you can just go to  &#8220;Properties&#8221; to add up to 255 timers in this file.   If you need more than 255 timers, you can simply create another timer data table, such as T9.   The &#8220;Usage&#8221; button in the data table will show you what timers are already in use.   In this example, we will use T4:1.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"490\" height=\"239\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TimerTable2.png\" alt=\"\" class=\"wp-image-1787 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TimerTable2.png 490w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TimerTable2-300x146.png 300w\" data-sizes=\"(max-width: 490px) 100vw, 490px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 490px; --smush-placeholder-aspect-ratio: 490\/239;\" \/><\/figure>\n\n\n\n<p>Here is an example of how a TOF Instruction might be used in logic.  Here we have an example of a motor with an external blower motor.   The external blower motor will keep the main motor cool while it&#8217;s running, and for 15 seconds after it has been shut off.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"841\" height=\"435\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic.png\" alt=\"SLC 500 Off Delay Timer in logic\n\" class=\"wp-image-1788 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic.png 841w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic-300x155.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic-768x397.png 768w\" data-sizes=\"(max-width: 841px) 100vw, 841px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 841px; --smush-placeholder-aspect-ratio: 841\/435;\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Timer Operation<\/h2>\n\n\n\n<p>When we energize the switch (I:1\/1), both the EN (Enable) and DN (Done) bit goes true right away.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"903\" height=\"458\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic1.png\" alt=\"SLC 500 Off Delay Timer Running\" class=\"wp-image-1789 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic1.png 903w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic1-300x152.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic1-768x390.png 768w\" data-sizes=\"(max-width: 903px) 100vw, 903px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 903px; --smush-placeholder-aspect-ratio: 903\/458;\" \/><\/figure>\n\n\n\n<p>When the Main Switch is shut off, the Main Motor will shut off.   This is on the EN (Enable Bit).  The timer will begin to time, The DN (Done) Bit is still on.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"917\" height=\"458\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic2.png\" alt=\"SLC 500 Off Delay Timer (when finished running)\" class=\"wp-image-1790 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic2.png 917w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic2-300x150.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic2-768x384.png 768w\" data-sizes=\"(max-width: 917px) 100vw, 917px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 917px; --smush-placeholder-aspect-ratio: 917\/458;\" \/><\/figure>\n\n\n\n<p>After the timer times out, then DN (Done) bit shuts off, and the accumulated value remains at the preset until the TOF instruction is energized again.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"904\" height=\"466\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic3.png\" alt=\"\" class=\"wp-image-1791 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic3.png 904w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic3-300x155.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic3-768x396.png 768w\" data-sizes=\"(max-width: 904px) 100vw, 904px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 904px; --smush-placeholder-aspect-ratio: 904\/466;\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Summary of the SLC 500 Off Delay Timer<\/h2>\n\n\n\n<p>When the Timer Off Delay instruction goes true, the DN and EN go true right away.   When the TOF goes false, the DN bit shuts off later (after the accumulated value reaches the preset.  Use this timer to delay an event from shutting off, or to hold a bit true for a specific amount of time.<\/p>\n\n\n\n<p>For more information on the SLC 500, Visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/slc500\/\">SLC 500 Category page.<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-2721345235\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to the SLC 500 Off Delay Timer The SLC 500 Off Delay Timer (TOF) Delays the DN (Done) bit from shutting off. Many people will find this as the most confusing type of timer. Once you understand it&#8217;s operation, and relate it to a real process, however, its easy to use. Examples of an <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":1789,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[130],"tags":[133,23],"class_list":{"0":"post-1786","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-slc500","8":"tag-slc-500","9":"tag-tof","10":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SLC 500 Off Delay Timer (TOF) Instruction operation<\/title>\n<meta name=\"description\" content=\"SLC 500 Off Delay Timer (TOF) Instruction. Here we will discuss the operation of the TOF instructions, and examples of how it is used.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SLC 500 Off Delay Timer (TOF) Instruction operation\" \/>\n<meta property=\"og:description\" content=\"SLC 500 Off Delay Timer (TOF) Instruction. Here we will discuss the operation of the TOF instructions, and examples of how it is used.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2019-03-28T11:12:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-11-11T10:15:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"903\" \/>\n\t<meta property=\"og:image:height\" content=\"458\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"SLC 500 Off Delay Timer\",\"datePublished\":\"2019-03-28T11:12:53+00:00\",\"dateModified\":\"2022-11-11T10:15:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/\"},\"wordCount\":503,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/TOFLogic1.png\",\"keywords\":[\"SLC-500\",\"tof\"],\"articleSection\":[\"SLC500\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/\",\"name\":\"SLC 500 Off Delay Timer (TOF) Instruction operation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/TOFLogic1.png\",\"datePublished\":\"2019-03-28T11:12:53+00:00\",\"dateModified\":\"2022-11-11T10:15:41+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"SLC 500 Off Delay Timer (TOF) Instruction. Here we will discuss the operation of the TOF instructions, and examples of how it is used.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/TOFLogic1.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2019\\\/03\\\/TOFLogic1.png\",\"width\":903,\"height\":458,\"caption\":\"Timer Off Delay\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/03\\\/28\\\/slc-500-tof-instruction\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SLC 500 Off Delay Timer\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SLC 500 Off Delay Timer (TOF) Instruction operation","description":"SLC 500 Off Delay Timer (TOF) Instruction. Here we will discuss the operation of the TOF instructions, and examples of how it is used.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/","og_locale":"en_US","og_type":"article","og_title":"SLC 500 Off Delay Timer (TOF) Instruction operation","og_description":"SLC 500 Off Delay Timer (TOF) Instruction. Here we will discuss the operation of the TOF instructions, and examples of how it is used.","og_url":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2019-03-28T11:12:53+00:00","article_modified_time":"2022-11-11T10:15:41+00:00","og_image":[{"width":903,"height":458,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic1.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"SLC 500 Off Delay Timer","datePublished":"2019-03-28T11:12:53+00:00","dateModified":"2022-11-11T10:15:41+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/"},"wordCount":503,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic1.png","keywords":["SLC-500","tof"],"articleSection":["SLC500"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/","url":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/","name":"SLC 500 Off Delay Timer (TOF) Instruction operation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic1.png","datePublished":"2019-03-28T11:12:53+00:00","dateModified":"2022-11-11T10:15:41+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"SLC 500 Off Delay Timer (TOF) Instruction. Here we will discuss the operation of the TOF instructions, and examples of how it is used.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic1.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/03\/TOFLogic1.png","width":903,"height":458,"caption":"Timer Off Delay"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2019\/03\/28\/slc-500-tof-instruction\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"SLC 500 Off Delay Timer"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/1786","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=1786"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/1786\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/1789"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=1786"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=1786"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=1786"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}