{"id":1895,"date":"2019-10-03T00:12:29","date_gmt":"2019-10-03T00:12:29","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=1895"},"modified":"2019-10-03T00:12:32","modified_gmt":"2019-10-03T00:12:32","slug":"slc-500-basic-instructions","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/","title":{"rendered":"SLC-500 Basic Instructions"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Introduction to SLC-500 Basic Instructions<\/h3>\n\n\n\n<p>When you are new to programming, there are 3 SLC-500 Basic Instructions that are a good place to start.  In this document, we will discuss the operation of each of these instructions in ladder logic.  These instructions include:<\/p><div id=\"bryce-3072146504\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<ul class=\"wp-block-list\"><li>XIC (Examine if Closed) &#8212; or &#8220;Examine ON&#8221;<\/li><li>XIO (Examine if Open) &#8212; or &#8220;Examine OFF&#8221;<\/li><li>OTE (Output to Energize)<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">The XIC Instruction<\/h3>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/10\/XIC.png\" alt=\"\" class=\"wp-image-1896 lazyload\" width=\"77\" height=\"83\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 77px; --smush-placeholder-aspect-ratio: 77\/83;\" \/><figcaption>Examine if Closed (False)<\/figcaption><\/figure><\/div>\n\n\n\n<p>First of all, I&#8217;ll discuss the XIC instruction.   Undoubtedly, this is one of the most common instructions in ladder logic.   In general, the XIC can look at most any bit anywhere in memory.   As long as that bit has the value of 1, the instruction is true.   However, when the bit we examine has the value of zero, the instruction is false.  As an illustration, I&#8217;ll place the value of 1 into B3:0\/0.   Notice the instruction &#8220;Intensifies&#8221; indicating the instruction is true. An example of where you might see an XIC would be on a start switch for a motor.   The XIC would go true when the operator energizes the start switch.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter is-resized\"><img decoding=\"async\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/10\/XICHighlighted.png\" alt=\"\" class=\"wp-image-1897 lazyload\" width=\"100\" height=\"75\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 100px; --smush-placeholder-aspect-ratio: 100\/75;\" \/><figcaption>Examine if Closed (True)<\/figcaption><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">The XIO Instruction<\/h3>\n\n\n\n<p>The XIO instruction is used in logic for conditions that we need to evaluate as false.    Similarly, the XIO instruction can generally look at any bit anywhere in memory.   If that bit is a 0, the instruction is true.   When the bit contains the value of 1, the instruction is false.   An example of usage would be for alarms.   When the operator presses a button to start a motor, we can check to make sure no alarm conditions exist before the motor will start.  When the instruction is intensified (such as shown), the instruction has logical continuity.  Think of this as a &#8220;NOT&#8221; instruction.   In this case, B3:0\/2 has to NOT be on.   It must contain the value of 0 for the instruction to be true.<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img decoding=\"async\" width=\"198\" height=\"86\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/10\/XIO.png\" alt=\"\" class=\"wp-image-1898 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 198px; --smush-placeholder-aspect-ratio: 198\/86;\" \/><figcaption>Examine if Open<\/figcaption><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Output to Energize<\/h3>\n\n\n\n<p>The Output to Energize instruction controls the bit we wish to manipulate based on the conditions of the rung.   For example:   The OTE can write the value of 1 or 0 to an output table to control a motor.   This will be based on the conditions before the rung.  Below is an example of how the OTE instruction appears in logic:<\/p>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter\"><img decoding=\"async\" width=\"92\" height=\"89\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/10\/OTE.png\" alt=\"\" class=\"wp-image-1899 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 92px; --smush-placeholder-aspect-ratio: 92\/89;\" \/><figcaption>Output To Energize<\/figcaption><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Putting it all together<\/h3>\n\n\n\n<p>Consider the following rung as an example:<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"894\" height=\"116\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/10\/rung.png\" alt=\"\" class=\"wp-image-1900 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/10\/rung.png 894w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/10\/rung-300x39.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/10\/rung-768x100.png 768w\" data-sizes=\"(max-width: 894px) 100vw, 894px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 894px; --smush-placeholder-aspect-ratio: 894\/116;\" \/><\/figure>\n\n\n\n<p>In this example, B3:0\/0 represents the state of a start switch.  B3:0\/2 represents an alarm condition, and B3:0\/1 controls a motor.  In order for the motor to run, the start switch must be on, and we need for the alarm to be clear (value of 0), then the motor will start.<\/p>\n\n\n\n<p>For more information on the SLC-500, check out the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/slc500\/\">Category Page!<\/a><\/p>\n\n\n\n<p>For a full list of SLC-500 instructions, go to the <a href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/rm\/1747-rm001_-en-p.pdf\">Instruction Set Reference Manual.<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-3670142366\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to SLC-500 Basic Instructions When you are new to programming, there are 3 SLC-500 Basic Instructions that are a good place to start. In this document, we will discuss the operation of each of these instructions in ladder logic. These instructions include: XIC (Examine if Closed) &#8212; or &#8220;Examine ON&#8221; XIO (Examine if Open) <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":1852,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[130],"tags":[17,154,152,153],"class_list":{"0":"post-1895","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-slc500","8":"tag-basic-instructions","9":"tag-ote","10":"tag-xic","11":"tag-xio","12":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Operation of SLC-500 Basic instructions. XIC, XIO, and OTE.<\/title>\n<meta name=\"description\" content=\"We will discuss the three basic instructions in the SLC-500 processor. This includes the Examine if Closed, Examine if Open, and Output to Energize.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Operation of SLC-500 Basic instructions. XIC, XIO, and OTE.\" \/>\n<meta property=\"og:description\" content=\"We will discuss the three basic instructions in the SLC-500 processor. This includes the Examine if Closed, Examine if Open, and Output to Energize.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2019-10-03T00:12:29+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-10-03T00:12:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/09\/continuelogic.png\" \/>\n\t<meta property=\"og:image:width\" content=\"481\" \/>\n\t<meta property=\"og:image:height\" content=\"416\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"SLC-500 Basic Instructions\",\"datePublished\":\"2019-10-03T00:12:29+00:00\",\"dateModified\":\"2019-10-03T00:12:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/\"},\"wordCount\":471,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2019\\\/09\\\/continuelogic.png\",\"keywords\":[\"Basic Instructions\",\"OTE\",\"XIC\",\"XIO\"],\"articleSection\":[\"SLC500\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/\",\"name\":\"Operation of SLC-500 Basic instructions. XIC, XIO, and OTE.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2019\\\/09\\\/continuelogic.png\",\"datePublished\":\"2019-10-03T00:12:29+00:00\",\"dateModified\":\"2019-10-03T00:12:32+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"We will discuss the three basic instructions in the SLC-500 processor. This includes the Examine if Closed, Examine if Open, and Output to Energize.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2019\\\/09\\\/continuelogic.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2019\\\/09\\\/continuelogic.png\",\"width\":481,\"height\":416,\"caption\":\"TrapList\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/10\\\/03\\\/slc-500-basic-instructions\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SLC-500 Basic Instructions\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Operation of SLC-500 Basic instructions. XIC, XIO, and OTE.","description":"We will discuss the three basic instructions in the SLC-500 processor. This includes the Examine if Closed, Examine if Open, and Output to Energize.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/","og_locale":"en_US","og_type":"article","og_title":"Operation of SLC-500 Basic instructions. XIC, XIO, and OTE.","og_description":"We will discuss the three basic instructions in the SLC-500 processor. This includes the Examine if Closed, Examine if Open, and Output to Energize.","og_url":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2019-10-03T00:12:29+00:00","article_modified_time":"2019-10-03T00:12:32+00:00","og_image":[{"width":481,"height":416,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/09\/continuelogic.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"SLC-500 Basic Instructions","datePublished":"2019-10-03T00:12:29+00:00","dateModified":"2019-10-03T00:12:32+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/"},"wordCount":471,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/09\/continuelogic.png","keywords":["Basic Instructions","OTE","XIC","XIO"],"articleSection":["SLC500"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/","url":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/","name":"Operation of SLC-500 Basic instructions. XIC, XIO, and OTE.","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/09\/continuelogic.png","datePublished":"2019-10-03T00:12:29+00:00","dateModified":"2019-10-03T00:12:32+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"We will discuss the three basic instructions in the SLC-500 processor. This includes the Examine if Closed, Examine if Open, and Output to Energize.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/09\/continuelogic.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/09\/continuelogic.png","width":481,"height":416,"caption":"TrapList"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2019\/10\/03\/slc-500-basic-instructions\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"SLC-500 Basic Instructions"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/1895","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=1895"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/1895\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/1852"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=1895"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=1895"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=1895"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}