{"id":2118,"date":"2019-12-19T09:21:04","date_gmt":"2019-12-19T09:21:04","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=2118"},"modified":"2020-02-04T10:59:46","modified_gmt":"2020-02-04T10:59:46","slug":"plc-5-output-modules","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/","title":{"rendered":"PLC-5 Output Modules"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Introduction to PLC-5 Output modules<\/h3>\n\n\n\n<p>The PLC-5 Output modules control devices.    In this post, we will discuss the discrete modules (on\/off conditions).   The Output modules simply act as a switch to turn on or off a load.    Examples of field devices attached to output modules include valves, solenoids, indicator lights, and motor starter coils.  There are several types of output modules depending on which switching type is required.  Triac, Transistor, and Relay control are an examples of the types of switches you might see in your application.<\/p><div id=\"bryce-3674297259\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Wiring the Module<\/h3>\n\n\n\n<p>Make your connections through a wiring arm that attaches to the chassis.    This might also be called a &#8220;swing arm&#8221;.    In the meantime, with a slight twisting motion, apply the wiring arm to the bottom rail of the chassis.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1024\" height=\"768\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/WiringArm-1024x768.jpg\" alt=\"\" class=\"wp-image-2119 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/WiringArm-1024x768.jpg 1024w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/WiringArm-300x225.jpg 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/WiringArm-768x576.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/WiringArm.jpg 1000w\" data-sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/768;\" \/><\/figure>\n\n\n\n<p>In this case, wire your DC + to the top 4 terminals.  This will increase the amount of current that can flow into the card.   In the same way, connect your DC Common to the bottom terminal.   Connect the other terminals to your field devices.  Most importantly, remember that in the PLC-5, all I\/O is in OCTAL.   <\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"768\" height=\"1024\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/WiringDiagram-e1576744833265-768x1024.jpg\" alt=\"Output Wiring Diagram\" class=\"wp-image-2122 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/WiringDiagram-e1576744833265-768x1024.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/WiringDiagram-e1576744833265-225x300.jpg 225w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/WiringDiagram-e1576744833265.jpg 750w\" data-sizes=\"(max-width: 768px) 100vw, 768px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 768px; --smush-placeholder-aspect-ratio: 768\/1024;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Status Indicators<\/h3>\n\n\n\n<p>The status indicators are used for troubleshooting.   If a status indicator is on, the processor is calling for the output to energize.  To emphasize, this does not mean the field device actually energized.    In essence, if the processor calls for the output, and the output is not energized, go to your schematic.  At this point, you will trace down the problem in the wiring or field devices.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"768\" height=\"1024\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/StatusIndicators-e1576745356296-768x1024.jpg\" alt=\"Status Indicators\" class=\"wp-image-2123 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/StatusIndicators-e1576745356296-768x1024.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/StatusIndicators-e1576745356296-225x300.jpg 225w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/StatusIndicators-e1576745356296.jpg 750w\" data-sizes=\"(max-width: 768px) 100vw, 768px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 768px; --smush-placeholder-aspect-ratio: 768\/1024;\" \/><\/figure>\n\n\n\n<p>Notice that the output module has a fuse light.   If this light is on, the fuse is likely blown.  Under those circumstances, replace the fuse on the side of the module.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"768\" height=\"1024\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/Fuse-e1576745706620-768x1024.jpg\" alt=\"Output Module Fuse\" class=\"wp-image-2125 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/Fuse-e1576745706620-768x1024.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/Fuse-e1576745706620-225x300.jpg 225w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/Fuse-e1576745706620.jpg 750w\" data-sizes=\"(max-width: 768px) 100vw, 768px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 768px; --smush-placeholder-aspect-ratio: 768\/1024;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Other Considerations<\/h3>\n\n\n\n<p>Be sure to check the jumper for &#8220;Last State&#8221; or &#8220;Reset&#8221;.   This jumper sets the condition of the outputs if the module detects a hardware failure.<\/p>\n\n\n\n<p>You might also want to check the hardware keys on the chassis backplane.    The hardware keys ensure that you can only insert the same type of module into the chassis.    Given that, they become brittle over time, and may have fallen to the bottom of your cabinet.    For more information on the hardware keys, consult the <a href=\"https:\/\/literature.rockwellautomation.com\/idc\/groups\/literature\/documents\/in\/1771-in053_-en-p.pdf\">installation manual.<\/a><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1024\" height=\"768\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/tabs-1024x768.jpg\" alt=\"\" class=\"wp-image-2219 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/tabs-1024x768.jpg 1024w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/tabs-300x225.jpg 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/tabs-768x576.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/tabs.jpg 1000w\" data-sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/768;\" \/><\/figure>\n\n\n\n<p>For more information on the PLC-5, visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/plc-5\/\">PLC-5 Category Page!<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-1625508298\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to PLC-5 Output modules The PLC-5 Output modules control devices. In this post, we will discuss the discrete modules (on\/off conditions). The Output modules simply act as a switch to turn on or off a load. Examples of field devices attached to output modules include valves, solenoids, indicator lights, and motor starter coils. There <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":2123,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[167],"tags":[169,158],"class_list":{"0":"post-2118","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-plc-5","8":"tag-output-modules","9":"tag-plc-5","10":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>PLC-5 Output modules -- Installation, wiring, and troubleshooting<\/title>\n<meta name=\"description\" content=\"Information about installing and troubleshooting the output modules. We&#039;ll also discuss the types of modules, and examples of output field devices.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PLC-5 Output modules -- Installation, wiring, and troubleshooting\" \/>\n<meta property=\"og:description\" content=\"Information about installing and troubleshooting the output modules. We&#039;ll also discuss the types of modules, and examples of output field devices.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2019-12-19T09:21:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-02-04T10:59:46+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/StatusIndicators-e1576745356296.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"750\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"PLC-5 Output Modules\",\"datePublished\":\"2019-12-19T09:21:04+00:00\",\"dateModified\":\"2020-02-04T10:59:46+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/\"},\"wordCount\":389,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2019\\\/12\\\/StatusIndicators-e1576745356296.jpg\",\"keywords\":[\"Output Modules\",\"PLC-5\"],\"articleSection\":[\"PLC-5\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/\",\"name\":\"PLC-5 Output modules -- Installation, wiring, and troubleshooting\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2019\\\/12\\\/StatusIndicators-e1576745356296.jpg\",\"datePublished\":\"2019-12-19T09:21:04+00:00\",\"dateModified\":\"2020-02-04T10:59:46+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"Information about installing and troubleshooting the output modules. We'll also discuss the types of modules, and examples of output field devices.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2019\\\/12\\\/StatusIndicators-e1576745356296.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2019\\\/12\\\/StatusIndicators-e1576745356296.jpg\",\"width\":750,\"height\":1000,\"caption\":\"Status Indicators\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2019\\\/12\\\/19\\\/plc-5-output-modules\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PLC-5 Output Modules\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PLC-5 Output modules -- Installation, wiring, and troubleshooting","description":"Information about installing and troubleshooting the output modules. We'll also discuss the types of modules, and examples of output field devices.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/","og_locale":"en_US","og_type":"article","og_title":"PLC-5 Output modules -- Installation, wiring, and troubleshooting","og_description":"Information about installing and troubleshooting the output modules. We'll also discuss the types of modules, and examples of output field devices.","og_url":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2019-12-19T09:21:04+00:00","article_modified_time":"2020-02-04T10:59:46+00:00","og_image":[{"width":750,"height":1000,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/StatusIndicators-e1576745356296.jpg","type":"image\/jpeg"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"PLC-5 Output Modules","datePublished":"2019-12-19T09:21:04+00:00","dateModified":"2020-02-04T10:59:46+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/"},"wordCount":389,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/StatusIndicators-e1576745356296.jpg","keywords":["Output Modules","PLC-5"],"articleSection":["PLC-5"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/","url":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/","name":"PLC-5 Output modules -- Installation, wiring, and troubleshooting","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/StatusIndicators-e1576745356296.jpg","datePublished":"2019-12-19T09:21:04+00:00","dateModified":"2020-02-04T10:59:46+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"Information about installing and troubleshooting the output modules. We'll also discuss the types of modules, and examples of output field devices.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/StatusIndicators-e1576745356296.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2019\/12\/StatusIndicators-e1576745356296.jpg","width":750,"height":1000,"caption":"Status Indicators"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2019\/12\/19\/plc-5-output-modules\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"PLC-5 Output Modules"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2118","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=2118"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2118\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/2123"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=2118"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=2118"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=2118"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}