{"id":2188,"date":"2020-01-22T01:57:38","date_gmt":"2020-01-22T01:57:38","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=2188"},"modified":"2020-01-22T11:12:48","modified_gmt":"2020-01-22T11:12:48","slug":"1785-ke-module","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/","title":{"rendered":"1785-KE Module"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Introduction to the 1785-KE Module<\/h3>\n\n\n\n<p>The 1785-KE module allows you to easily interface with a Data Highway Plus (DH+) Network.  Although there are other ways to interface with DH+, I have found this method to be the most cost effective.   For example:  The 1784-U2DHP module could cost over $2000.   You can usually find a <a href=\"https:\/\/www.ebay.com\/sch\/i.html?_from=R40&amp;_trksid=p2380057.m570.l1313.TR1.TRC0.A0.H0.X1785-ke.TRS0&amp;_nkw=1785-ke&amp;_sacat=0\">1785-KE module from Ebay<\/a> for under $100.  Other methods include a ControlLogix gateway (with an Ethernet and a DHRIO module),  or an ANC-120e.<\/p><div id=\"bryce-3264090099\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1024\" height=\"768\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEChassis-1024x768.jpg\" alt=\"\" class=\"wp-image-2189 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEChassis-1024x768.jpg 1024w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEChassis-300x225.jpg 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEChassis-768x576.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEChassis.jpg 1000w\" data-sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/768;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Configuring the module<\/h3>\n\n\n\n<p>The configuration is very simple.   Although there are a lot of switches for configuration, the KE module has a label to describe each switch.   <\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"768\" height=\"1024\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KELabel-e1579655384676-768x1024.jpg\" alt=\"KE Label\" class=\"wp-image-2190 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KELabel-e1579655384676-768x1024.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KELabel-e1579655384676-225x300.jpg 225w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KELabel-e1579655384676.jpg 750w\" data-sizes=\"(max-width: 768px) 100vw, 768px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 768px; --smush-placeholder-aspect-ratio: 768\/1024;\" \/><\/figure>\n\n\n\n<p>This looks intimidating, but I set all of the switches in the DOWN position except for the very first switch, and the switches for the station number.    This provides for a common serial setting of 19,200 baud, 8 bit word length, 1 stop bit, Full Duplex, and CRC error checking.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1024\" height=\"768\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEswitches-1024x768.jpg\" alt=\"\" class=\"wp-image-2191 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEswitches-1024x768.jpg 1024w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEswitches-300x225.jpg 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEswitches-768x576.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEswitches.jpg 1000w\" data-sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/768;\" \/><\/figure>\n\n\n\n<p>As can be seen in the above image, I put the very first switch in the up (off) position.   The second bank is for the DH+ Node address.   By all means, do not use a node address that already exists on the DH+ Network.  The node address is in octal.   The first two switches represent the first digit of the octal node (in binary).  Because these switches are down, the first digit is 0.   The next three switches represent the second digit of the octal node.  In this case,  (010) in binary is 2.   The last 3 switches represent the last digit of the octal node.  Likewise, this digit is also 2.   Summing up, our node is 22.  With these settings, the DH+ Baud rate is 57.6k (which is the only baud rate this module supports for the DH+ Port.) <\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Wiring the the module<\/h3>\n\n\n\n<p>The most difficult part of getting the module up and running is setting up your serial cable.   As can be seen, I just used breakout terminals.  You need a 15 pin (2 row) male connector, and a 9 pin female connector.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1024\" height=\"768\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/fifteenpin-1024x768.jpg\" alt=\"\" class=\"wp-image-2192 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/fifteenpin-1024x768.jpg 1024w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/fifteenpin-300x225.jpg 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/fifteenpin-768x576.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/fifteenpin.jpg 1000w\" data-sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/768;\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"1024\" height=\"768\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/ninepin-1024x768.jpg\" alt=\"\" class=\"wp-image-2193 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/ninepin-1024x768.jpg 1024w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/ninepin-300x225.jpg 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/ninepin-768x576.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/ninepin.jpg 1000w\" data-sizes=\"(max-width: 1024px) 100vw, 1024px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1024px; --smush-placeholder-aspect-ratio: 1024\/768;\" \/><\/figure>\n\n\n\n<p>It&#8217;s difficult to see in the image, so I will list the connections below.   I had to research a little, because the manual for the 1785-KE module shows the connection to a 25 pin connector.   I cross referenced each pin to a 9 pin connector to use on more modern computers or USB to serial adapters.<\/p>\n\n\n\n<p>Jumpers on the 15 pin connector:   Jump pins 7 to 15 (GND to GND).  DSR (6) to DCD (8).  RTS (4) to CTS (5)<\/p>\n\n\n\n<p>Jumpers on the 9 pin connector:  DCD (1) to DSR (6).  RTS (7) to CTS (8).<\/p>\n\n\n\n<p>Connections FROM 15 pin TO 9 pin connector.   <\/p>\n\n\n\n<p>TXD (2) to RXD (3)<\/p>\n\n\n\n<p>RXD (3) to TXD (2)<\/p>\n\n\n\n<p>DSR (6) to DTR (4)<\/p>\n\n\n\n<p>DTR (11) to DSR (6)<\/p>\n\n\n\n<p>GND (7) to GND (5)<\/p>\n\n\n\n<p>For the DH+ Plug, connect your DH+ Network to the 3 pin phoenix connector.  Clear is usually #1 terminal on DH+, Shield in the center, and Blue on #2.  Check the rest of your nodes on the DH+ network to be sure the same color conductor is wired to terminal #1 and #2.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Configuring the driver in RSLinx<\/h3>\n\n\n\n<p>RSLinx is the communication server.   When configuring RSLinx, use the DF1 RS232 devices driver.  Be sure to select the proper COM port.   The Device will be the 1785-KE as shown.   I like to set the station # on 0.    If you use the Autoconfig button, your workstation will be set to the node number of your KE on DH+.  In essence, the workstation shows up in RSWho instead of the KE module if you use this setting.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"441\" height=\"441\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/DriverConfiguration.png\" alt=\"\" class=\"wp-image-2194 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/DriverConfiguration.png 441w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/DriverConfiguration-150x150.png 150w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/DriverConfiguration-300x300.png 300w\" data-sizes=\"(max-width: 441px) 100vw, 441px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 441px; --smush-placeholder-aspect-ratio: 441\/441;\" \/><\/figure>\n\n\n\n<p>When you look at the RSWho screen, you should see the rest of the network:  As can be seen, I have a different 1756-KE module currently running on Node 23 octal, and I&#8217;ve set the workstation (within the driver configuration) to Node 0.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"615\" height=\"204\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/RSWho.png\" alt=\"\" class=\"wp-image-2195 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/RSWho.png 615w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/RSWho-300x100.png 300w\" data-sizes=\"(max-width: 615px) 100vw, 615px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 615px; --smush-placeholder-aspect-ratio: 615\/204;\" \/><\/figure>\n\n\n\n<p>For more information on the PLC-5 system, visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/plc-5\/\">PLC-5 Category page!<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-63819816\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to the 1785-KE Module The 1785-KE module allows you to easily interface with a Data Highway Plus (DH+) Network. Although there are other ways to interface with DH+, I have found this method to be the most cost effective. For example: The 1784-U2DHP module could cost over $2000. You can usually find a 1785-KE <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":2189,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[167],"tags":[173,172,158],"class_list":{"0":"post-2188","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-plc-5","8":"tag-1785-ke","9":"tag-dh","10":"tag-plc-5","11":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>1785-KE Module -- Configuration, wiring, and driver configuration.<\/title>\n<meta name=\"description\" content=\"How to set the DIP switches and build your own cable for use with the 1785-KE module. This is a low cost alternative to connect to DH+.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"1785-KE Module -- Configuration, wiring, and driver configuration.\" \/>\n<meta property=\"og:description\" content=\"How to set the DIP switches and build your own cable for use with the 1785-KE module. This is a low cost alternative to connect to DH+.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-01-22T01:57:38+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-01-22T11:12:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEChassis.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"750\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"1785-KE Module\",\"datePublished\":\"2020-01-22T01:57:38+00:00\",\"dateModified\":\"2020-01-22T11:12:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/\"},\"wordCount\":618,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/01\\\/KEChassis.jpg\",\"keywords\":[\"1785-KE\",\"DH+\",\"PLC-5\"],\"articleSection\":[\"PLC-5\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/\",\"name\":\"1785-KE Module -- Configuration, wiring, and driver configuration.\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/01\\\/KEChassis.jpg\",\"datePublished\":\"2020-01-22T01:57:38+00:00\",\"dateModified\":\"2020-01-22T11:12:48+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"How to set the DIP switches and build your own cable for use with the 1785-KE module. This is a low cost alternative to connect to DH+.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/01\\\/KEChassis.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/01\\\/KEChassis.jpg\",\"width\":1000,\"height\":750,\"caption\":\"KE Module in chassis\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/01\\\/22\\\/1785-ke-module\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"1785-KE Module\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"1785-KE Module -- Configuration, wiring, and driver configuration.","description":"How to set the DIP switches and build your own cable for use with the 1785-KE module. This is a low cost alternative to connect to DH+.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/","og_locale":"en_US","og_type":"article","og_title":"1785-KE Module -- Configuration, wiring, and driver configuration.","og_description":"How to set the DIP switches and build your own cable for use with the 1785-KE module. This is a low cost alternative to connect to DH+.","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-01-22T01:57:38+00:00","article_modified_time":"2020-01-22T11:12:48+00:00","og_image":[{"width":1000,"height":750,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEChassis.jpg","type":"image\/jpeg"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"1785-KE Module","datePublished":"2020-01-22T01:57:38+00:00","dateModified":"2020-01-22T11:12:48+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/"},"wordCount":618,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEChassis.jpg","keywords":["1785-KE","DH+","PLC-5"],"articleSection":["PLC-5"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/","name":"1785-KE Module -- Configuration, wiring, and driver configuration.","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEChassis.jpg","datePublished":"2020-01-22T01:57:38+00:00","dateModified":"2020-01-22T11:12:48+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"How to set the DIP switches and build your own cable for use with the 1785-KE module. This is a low cost alternative to connect to DH+.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEChassis.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/01\/KEChassis.jpg","width":1000,"height":750,"caption":"KE Module in chassis"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/01\/22\/1785-ke-module\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"1785-KE Module"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2188","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=2188"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2188\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/2189"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=2188"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=2188"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=2188"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}