{"id":2222,"date":"2020-02-05T23:18:28","date_gmt":"2020-02-05T23:18:28","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=2222"},"modified":"2020-02-05T23:36:15","modified_gmt":"2020-02-05T23:36:15","slug":"sump-level-logic","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/","title":{"rendered":"Sump Level Logic"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Introduction to Sump Level Logic<\/h3>\n\n\n\n<p>When writing sump level logic, keep in mind, we need to know what the sump level is.   We usually provide that to the processor with an analog input.  We&#8217;ll assume that you have the level transmitter set up, we will scale this transmitter into inches.   Although I&#8217;m writing this logic for the ControlLogix processor, similar logic can be applied to other processors as well using the same concept.<\/p><div id=\"bryce-2224276746\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Configuring the modules<\/h3>\n\n\n\n<p>First, I&#8217;ll add two modules to the I\/O configuration.   I&#8217;m adding an output module to control the motor starter for the pump, and an analog input module to read the sump level.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"202\" height=\"75\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumpmodules.png\" alt=\"\" class=\"wp-image-2223 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 202px; --smush-placeholder-aspect-ratio: 202\/75;\" \/><figcaption><br><\/figcaption><\/figure>\n\n\n\n<p>Next, I&#8217;ll go to the properties of the analog input module in slot 2.   I&#8217;m going to scale Channel 0 to 0 to 50 inches.   This is based on a 4 to 20ma signal from the transmitter.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"563\" height=\"339\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumpanalogconfig.png\" alt=\"\" class=\"wp-image-2225 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumpanalogconfig.png 563w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumpanalogconfig-300x181.png 300w\" data-sizes=\"(max-width: 563px) 100vw, 563px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 563px; --smush-placeholder-aspect-ratio: 563\/339;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Set up the Tags<\/h3>\n\n\n\n<p>Thirdly, I&#8217;ll add some aliases.   This will make our logic easier to understand later on.  The tag called SumpPump will point to Local:6:O.Data.0.   Likewise, the tag called SumpLevel will point to Local:2:I.Ch0Data.   This will be our analog tag.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"492\" height=\"206\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/SumpTags.png\" alt=\"\" class=\"wp-image-2226 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/SumpTags.png 492w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/SumpTags-300x126.png 300w\" data-sizes=\"(max-width: 492px) 100vw, 492px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 492px; --smush-placeholder-aspect-ratio: 492\/206;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Write the Logic<\/h3>\n\n\n\n<p>In this example, we&#8217;ll have the pump turn on at 15 inches, and off at 5 inches.  We&#8217;ll just need some simple compare instructions to make this happen.  We&#8217;ll use &#8220;Seal-In&#8221; Logic for this to happen.   A &#8220;Seal-In&#8221; branch is when we have an XIC on a branch with the same address at the output instruction.<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" width=\"644\" height=\"374\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumplogic.png\" alt=\"\" class=\"wp-image-2227 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumplogic.png 644w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumplogic-300x174.png 300w\" data-sizes=\"(max-width: 644px) 100vw, 644px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 644px; --smush-placeholder-aspect-ratio: 644\/374;\" \/><\/figure>\n\n\n\n<p>Notice that when the sump level exceeds 15 inches, the SumpPump tag will energize.   In the next branch, the XIC is true for the SumpPump.   Certainly if the SumpLevel is above 15, it will be above 5 inches.   However, when the sump level drops below 15 inches, the bottom branch is still true.   Furthermore, the bottom branch remains true until the sump level drops to 5 inches.   This is when the seal is broken, and the SumpPump bit shuts off.<\/p>\n\n\n\n<p>It&#8217;s important to realize, however, that if your motor starter has an auxiliary contact, you could use an input to seal the bottom branch instead of the address of the output.   This ensures that the motor starter did indeed engage before sealing the rung.<\/p>\n\n\n\n<p>This is just a simple example, and will not apply to all applications.    Always be sure take any safety precautions into account before using any logic on this site in any way.<\/p>\n\n\n\n<p>For more information on ControlLogix, visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/controllogix\/\">ControlLogix Category Page!<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-1355013143\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to Sump Level Logic When writing sump level logic, keep in mind, we need to know what the sump level is. We usually provide that to the processor with an analog input. We&#8217;ll assume that you have the level transmitter set up, we will scale this transmitter into inches. Although I&#8217;m writing this logic <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":2227,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[28,11,176],"class_list":{"0":"post-2222","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-controllogix","8":"tag-analog","9":"tag-controllogix","10":"tag-sump-level","11":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Sump Level Logic -- Control a sump level in the ControlLogix system<\/title>\n<meta name=\"description\" content=\"How to scale the analog module, write tags with aliases, and ladder logic to control a sump level using the ControlLogix system.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Sump Level Logic -- Control a sump level in the ControlLogix system\" \/>\n<meta property=\"og:description\" content=\"How to scale the analog module, write tags with aliases, and ladder logic to control a sump level using the ControlLogix system.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-02-05T23:18:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-02-05T23:36:15+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumplogic.png\" \/>\n\t<meta property=\"og:image:width\" content=\"644\" \/>\n\t<meta property=\"og:image:height\" content=\"374\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"Sump Level Logic\",\"datePublished\":\"2020-02-05T23:18:28+00:00\",\"dateModified\":\"2020-02-05T23:36:15+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/\"},\"wordCount\":423,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/sumplogic.png\",\"keywords\":[\"Analog\",\"ControlLogix\",\"Sump Level\"],\"articleSection\":[\"ControlLogix\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/\",\"name\":\"Sump Level Logic -- Control a sump level in the ControlLogix system\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/sumplogic.png\",\"datePublished\":\"2020-02-05T23:18:28+00:00\",\"dateModified\":\"2020-02-05T23:36:15+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"How to scale the analog module, write tags with aliases, and ladder logic to control a sump level using the ControlLogix system.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/sumplogic.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/02\\\/sumplogic.png\",\"width\":644,\"height\":374,\"caption\":\"Sump Level Logic\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/02\\\/05\\\/sump-level-logic\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Sump Level Logic\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Sump Level Logic -- Control a sump level in the ControlLogix system","description":"How to scale the analog module, write tags with aliases, and ladder logic to control a sump level using the ControlLogix system.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/","og_locale":"en_US","og_type":"article","og_title":"Sump Level Logic -- Control a sump level in the ControlLogix system","og_description":"How to scale the analog module, write tags with aliases, and ladder logic to control a sump level using the ControlLogix system.","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-02-05T23:18:28+00:00","article_modified_time":"2020-02-05T23:36:15+00:00","og_image":[{"width":644,"height":374,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumplogic.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"Sump Level Logic","datePublished":"2020-02-05T23:18:28+00:00","dateModified":"2020-02-05T23:36:15+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/"},"wordCount":423,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumplogic.png","keywords":["Analog","ControlLogix","Sump Level"],"articleSection":["ControlLogix"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/","name":"Sump Level Logic -- Control a sump level in the ControlLogix system","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumplogic.png","datePublished":"2020-02-05T23:18:28+00:00","dateModified":"2020-02-05T23:36:15+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"How to scale the analog module, write tags with aliases, and ladder logic to control a sump level using the ControlLogix system.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumplogic.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/02\/sumplogic.png","width":644,"height":374,"caption":"Sump Level Logic"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/02\/05\/sump-level-logic\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"Sump Level Logic"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2222","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=2222"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2222\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/2227"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=2222"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=2222"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=2222"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}