{"id":2440,"date":"2020-06-19T15:52:25","date_gmt":"2020-06-19T15:52:25","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=2440"},"modified":"2021-06-18T10:40:00","modified_gmt":"2021-06-18T10:40:00","slug":"factorytalk-view-me-with-rsemulate","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/","title":{"rendered":"FactoryTalk View ME with RSEmulate"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">Introduction to using FactoryTalk View ME with RSEmulate<\/h4>\n\n\n\n<p>You might use FactoryTalk View ME with RSEmulate to experiment with objects in the FactoryTalk View ME software.   FactoryTalk View ME is HMI software.   This allows you to create a graphical interface for the operator to interface with the PLC Processor.   RSEmulate is software that runs on your PC to simulate an actual ControlLogix processor to some extent.<\/p><div id=\"bryce-4063451095\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<p>In this example, I will display the value of a simple tag called &#8220;MyTag&#8221; that has the DINT data type.   In these examples, I&#8217;m using FactoryTalk View ME Version 11.  Studio 5000 and RSEmulate are running version 24.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Add a processor to the Emulator<\/h4>\n\n\n\n<p>First, open RSEmulate, and add a processor to the virtual chassis.    In this example, I will add the processor to slot 2.  <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"682\" height=\"562\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Emulator.png\" alt=\"\" class=\"wp-image-2442 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Emulator.png 682w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Emulator-300x247.png 300w\" data-sizes=\"(max-width: 682px) 100vw, 682px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 682px; --smush-placeholder-aspect-ratio: 682\/562;\" \/><\/figure>\n\n\n\n<p>I&#8217;m going to add the controller as version 24.   Then I&#8217;ll click &#8220;Next&#8221; and &#8220;Finish&#8221;<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"578\" height=\"335\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Emulateor2.jpg\" alt=\"\" class=\"wp-image-2444 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Emulateor2.jpg 578w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Emulateor2-300x174.jpg 300w\" data-sizes=\"(max-width: 578px) 100vw, 578px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 578px; --smush-placeholder-aspect-ratio: 578\/335;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Set up the Virtual Backplane Driver in RSLinx<\/h4>\n\n\n\n<p>Secondly, in order to communicate with the emulator, we must configure the virtual backplane driver in RSLinx.    To do this, go to Communications | Configure Drivers.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"482\" height=\"317\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/backplanedriver.png\" alt=\"\" class=\"wp-image-2447 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/backplanedriver.png 482w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/backplanedriver-300x197.png 300w\" data-sizes=\"(max-width: 482px) 100vw, 482px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 482px; --smush-placeholder-aspect-ratio: 482\/317;\" \/><\/figure>\n\n\n\n<p>To be sure that you are communicating, go to the RSWho Screen.  Click on the Virtual Backplane Driver to verify communication.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"737\" height=\"180\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/rswho.png\" alt=\"\" class=\"wp-image-2448 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/rswho.png 737w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/rswho-300x73.png 300w\" data-sizes=\"(max-width: 737px) 100vw, 737px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 737px; --smush-placeholder-aspect-ratio: 737\/180;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Create the Studio 5000 Project<\/h4>\n\n\n\n<p>Thirdly, we&#8217;ll create a project in Studio 5000.   Be sure to select the emulator as your controller.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"556\" height=\"243\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/selectemulator.jpg\" alt=\"\" class=\"wp-image-2445 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/selectemulator.jpg 556w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/selectemulator-300x131.jpg 300w\" data-sizes=\"(max-width: 556px) 100vw, 556px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 556px; --smush-placeholder-aspect-ratio: 556\/243;\" \/><\/figure>\n\n\n\n<p>Then, click &#8220;Next&#8221;, and I&#8217;ll select the version as 24.   Be sure the controller is assigned the proper slot number.  Click &#8220;Finish&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"729\" height=\"590\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/version.jpg\" alt=\"\" class=\"wp-image-2446 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/version.jpg 729w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/version-300x243.jpg 300w\" data-sizes=\"(max-width: 729px) 100vw, 729px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 729px; --smush-placeholder-aspect-ratio: 729\/590;\" \/><\/figure>\n\n\n\n<p>I&#8217;ll add the tag, &#8220;MyTag&#8221; as a DINT, and give it a test value of 500.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"526\" height=\"87\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/tag.jpg\" alt=\"\" class=\"wp-image-2450 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/tag.jpg 526w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/tag-300x50.jpg 300w\" data-sizes=\"(max-width: 526px) 100vw, 526px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 526px; --smush-placeholder-aspect-ratio: 526\/87;\" \/><\/figure>\n\n\n\n<p>Then, download to your processor, by going to Communication | Who Active to browse for the processor.  Highlight the processor, and download.  Of course it&#8217;s a good idea to also put the processor into run mode if your logic will be changing this value for testing.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"712\" height=\"300\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Download.png\" alt=\"\" class=\"wp-image-2451 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Download.png 712w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Download-300x126.png 300w\" data-sizes=\"(max-width: 712px) 100vw, 712px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 712px; --smush-placeholder-aspect-ratio: 712\/300;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Create the FactoryTalk View ME application<\/h4>\n\n\n\n<p>Fourthly, create the test application in FactoryTalk View ME.  Under FactoryTalk Linx Enterprise (RSLinx Enterprise), go to Communication Setup.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"249\" height=\"58\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/ftlinx.jpg\" alt=\"\" class=\"wp-image-2452 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 249px; --smush-placeholder-aspect-ratio: 249\/58;\" \/><\/figure>\n\n\n\n<p>To demonstrate, I&#8217;ll create a new configuration.  Then, I&#8217;ll add a shortcut called &#8220;MyEmulator&#8221;.  As a result, &#8220;MyEmulator&#8221; will be a shortcut that represents the path to our emulator processor.   Right-click the backplane as shown, and add a device.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"791\" height=\"214\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/adddriver.jpg\" alt=\"\" class=\"wp-image-2454 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/adddriver.jpg 791w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/adddriver-300x81.jpg 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/adddriver-768x208.jpg 768w\" data-sizes=\"(max-width: 791px) 100vw, 791px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 791px; --smush-placeholder-aspect-ratio: 791\/214;\" \/><\/figure>\n\n\n\n<p>Expand the Emulator option.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"556\" height=\"138\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/FTEmulateExpand.jpg\" alt=\"\" class=\"wp-image-2460 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/FTEmulateExpand.jpg 556w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/FTEmulateExpand-300x74.jpg 300w\" data-sizes=\"(max-width: 556px) 100vw, 556px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 556px; --smush-placeholder-aspect-ratio: 556\/138;\" \/><\/figure>\n\n\n\n<p>In this case, I&#8217;ll choose the Logix 55xx Emulator as Version 24.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"555\" height=\"446\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/ftemulateversion.jpg\" alt=\"\" class=\"wp-image-2461 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/ftemulateversion.jpg 555w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/ftemulateversion-300x241.jpg 300w\" data-sizes=\"(max-width: 555px) 100vw, 555px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 555px; --smush-placeholder-aspect-ratio: 555\/446;\" \/><\/figure>\n\n\n\n<p>With this in mind, choose the correct slot of the emulator, then press OK.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"492\" height=\"426\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/EmulatorSlot.jpg\" alt=\"\" class=\"wp-image-2459 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/EmulatorSlot.jpg 492w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/EmulatorSlot-300x260.jpg 300w\" data-sizes=\"(max-width: 492px) 100vw, 492px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 492px; --smush-placeholder-aspect-ratio: 492\/426;\" \/><\/figure>\n\n\n\n<p>Be sure to hit &#8220;Apply&#8221; and OK.  If you are going to run this on an ME Station, be sure to copy from design to runtime before you hit OK.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"389\" height=\"98\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Apply.jpg\" alt=\"\" class=\"wp-image-2462 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Apply.jpg 389w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Apply-300x76.jpg 300w\" data-sizes=\"(max-width: 389px) 100vw, 389px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 389px; --smush-placeholder-aspect-ratio: 389\/98;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Add an object<\/h4>\n\n\n\n<p>Finally, we are ready to add an object.  This will be our test to make sure FactoryTalk View ME with RSEmulate is working.<\/p>\n\n\n\n<p>On the Main Screen, I will ad a Numeric display object.  Furthermore, on the &#8220;Connections&#8221; tab, we will browse for a tag.  Under &#8220;My Emulator&#8221;, click the online folder, and choose your tag.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"671\" height=\"491\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/tags.jpg\" alt=\"\" class=\"wp-image-2464 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/tags.jpg 671w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/tags-300x220.jpg 300w\" data-sizes=\"(max-width: 671px) 100vw, 671px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 671px; --smush-placeholder-aspect-ratio: 671\/491;\" \/><\/figure>\n\n\n\n<p>Test run your application, and you should see the value displayed on your numeric display object.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"182\" height=\"78\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/numeric.jpg\" alt=\"\" class=\"wp-image-2466 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 182px; --smush-placeholder-aspect-ratio: 182\/78;\" \/><\/figure>\n\n\n\n<p>For more information on FactoryTalk View ME, please visit the<a href=\"https:\/\/bryceautomation.com\/index.php\/category\/factorytalk-view-me\/\"> category page<\/a>!<\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-37124991\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to using FactoryTalk View ME with RSEmulate You might use FactoryTalk View ME with RSEmulate to experiment with objects in the FactoryTalk View ME software. FactoryTalk View ME is HMI software. This allows you to create a graphical interface for the operator to interface with the PLC Processor. RSEmulate is software that runs on <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":2442,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[50],"tags":[51,194],"class_list":{"0":"post-2440","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-factorytalk-view-me","8":"tag-factorytalk-view","9":"tag-rsemulate","10":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>FactoryTalk View ME with RSEmulate - Bryce Automation<\/title>\n<meta name=\"description\" content=\"How to set up FactoryTalk View ME with RSEmulate. This will help you test your projects before implementing your actual HMI project.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FactoryTalk View ME with RSEmulate - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"How to set up FactoryTalk View ME with RSEmulate. This will help you test your projects before implementing your actual HMI project.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-06-19T15:52:25+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-06-18T10:40:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Emulator.png\" \/>\n\t<meta property=\"og:image:width\" content=\"682\" \/>\n\t<meta property=\"og:image:height\" content=\"562\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"FactoryTalk View ME with RSEmulate\",\"datePublished\":\"2020-06-19T15:52:25+00:00\",\"dateModified\":\"2021-06-18T10:40:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/\"},\"wordCount\":525,\"commentCount\":2,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/06\\\/Emulator.png\",\"keywords\":[\"FactoryTalk View\",\"RSEmulate\"],\"articleSection\":[\"FactoryTalk View ME\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/\",\"name\":\"FactoryTalk View ME with RSEmulate - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/06\\\/Emulator.png\",\"datePublished\":\"2020-06-19T15:52:25+00:00\",\"dateModified\":\"2021-06-18T10:40:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"How to set up FactoryTalk View ME with RSEmulate. This will help you test your projects before implementing your actual HMI project.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/06\\\/Emulator.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/06\\\/Emulator.png\",\"width\":682,\"height\":562,\"caption\":\"RSEmulate\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/06\\\/19\\\/factorytalk-view-me-with-rsemulate\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FactoryTalk View ME with RSEmulate\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FactoryTalk View ME with RSEmulate - Bryce Automation","description":"How to set up FactoryTalk View ME with RSEmulate. This will help you test your projects before implementing your actual HMI project.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/","og_locale":"en_US","og_type":"article","og_title":"FactoryTalk View ME with RSEmulate - Bryce Automation","og_description":"How to set up FactoryTalk View ME with RSEmulate. This will help you test your projects before implementing your actual HMI project.","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-06-19T15:52:25+00:00","article_modified_time":"2021-06-18T10:40:00+00:00","og_image":[{"width":682,"height":562,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Emulator.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"FactoryTalk View ME with RSEmulate","datePublished":"2020-06-19T15:52:25+00:00","dateModified":"2021-06-18T10:40:00+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/"},"wordCount":525,"commentCount":2,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Emulator.png","keywords":["FactoryTalk View","RSEmulate"],"articleSection":["FactoryTalk View ME"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/","name":"FactoryTalk View ME with RSEmulate - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Emulator.png","datePublished":"2020-06-19T15:52:25+00:00","dateModified":"2021-06-18T10:40:00+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"How to set up FactoryTalk View ME with RSEmulate. This will help you test your projects before implementing your actual HMI project.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Emulator.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/06\/Emulator.png","width":682,"height":562,"caption":"RSEmulate"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/06\/19\/factorytalk-view-me-with-rsemulate\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"FactoryTalk View ME with RSEmulate"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2440","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=2440"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2440\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/2442"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=2440"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=2440"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=2440"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}