{"id":2540,"date":"2020-08-11T14:15:45","date_gmt":"2020-08-11T14:15:45","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=2540"},"modified":"2020-11-15T21:05:09","modified_gmt":"2020-11-15T21:05:09","slug":"plantpax-4-digital-input","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/","title":{"rendered":"PlantPAx 4 Digital Input Instruction"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Introduction to PlantPAx 4 Digital Input Instruction<\/h3>\n\n\n\n<p>The PlantPAx 4 Digital Input instruction monitors discrete (digital) inputs in your system.   The advantage of using a P_Din for each input is that we will display the status of the input for the operator.  Another advantage is to ensure the switch has reached it&#8217;s target state.   In general, there are two steps to make this happen.   First, we will add the instruction to the processor logic.  Secondly, we will add the HMI object to a display.<\/p><div id=\"bryce-3363225541\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Import the Add on Instruction<\/h3>\n\n\n\n<p>To begin with the add-on instruction, first we must import this into our Studio 5000 project.   Right-click &#8220;Add-On Instructions&#8221;, and choose &#8220;Import Add-On Instruction&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"415\" height=\"87\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addon-1.png\" alt=\"\" class=\"wp-image-2542 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addon-1.png 415w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addon-1-300x63.png 300w\" data-sizes=\"(max-width: 415px) 100vw, 415px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 415px; --smush-placeholder-aspect-ratio: 415\/87;\" \/><\/figure>\n\n\n\n<p>Be sure to choose the P_Din instruction, then choose &#8220;Import&#8221;.   Obviously for more advanced features (such as in a speed switch), you can choose P_DinAdv.   <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"873\" height=\"537\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/din.png\" alt=\"\" class=\"wp-image-2543 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/din.png 873w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/din-300x185.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/din-768x472.png 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/din-570x350.png 570w\" data-sizes=\"(max-width: 873px) 100vw, 873px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 873px; --smush-placeholder-aspect-ratio: 873\/537;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Add the logic<\/h3>\n\n\n\n<p>At this time, we are ready to add the logic for the P_Din instruction to work.  I&#8217;m going to create a subroutine that is a function block type.   Be sure to add the JSR instruction from the MainRoutine.  <\/p>\n\n\n\n<p>As long as our instruction imported properly, we should find the P_Din instruction under Add-On instructions in the instruction toolbar.   As an illustration, add 4 input references, 1 output reference, and a P_Din instruction.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"666\" height=\"241\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/dininstruction.png\" alt=\"\" class=\"wp-image-2544 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/dininstruction.png 666w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/dininstruction-300x109.png 300w\" data-sizes=\"(max-width: 666px) 100vw, 666px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 666px; --smush-placeholder-aspect-ratio: 666\/241;\" \/><\/figure>\n\n\n\n<p>Finally, download your work to the training processor, and place the processor into remote run mode.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Import the Faceplates<\/h4>\n\n\n\n<p>There are a few faceplates that we want to import for the P_Din instruction.   Right click &#8220;Displays&#8221; under Graphics.   Select &#8220;Add Component into Application&#8221;.   Add the faceplates as shown from the GFX folder in your process objects folder.  We need P_Din-Advanced, P-Din_Faceplate, and P_Din-Quick.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"471\" height=\"112\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/10\/image.png\" alt=\"\" class=\"wp-image-3240 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/10\/image.png 471w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/10\/image-300x71.png 300w\" data-sizes=\"(max-width: 471px) 100vw, 471px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 471px; --smush-placeholder-aspect-ratio: 471\/112;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Add the PlantPAx 4 Digital Input HMI object<\/h3>\n\n\n\n<p>Our next step is to add the P_Din HMI object onto a display.  As I have said, we will point this object to the tag for the P_Din instruction.  By default, the tag is a program tag, and we added the instruction into the MainProgram.<\/p>\n\n\n\n<p>To demonstrate the P_Din object, I created a new display.   Locate the Process Graphics library under &#8220;Global Objects&#8221;.   Drag the first object onto your new display.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"731\" height=\"267\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-120.png\" alt=\"\" class=\"wp-image-3231 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-120.png 731w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-120-300x110.png 300w\" data-sizes=\"(max-width: 731px) 100vw, 731px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 731px; --smush-placeholder-aspect-ratio: 731\/267;\" \/><\/figure>\n\n\n\n<p>So long as we have already downloaded (and your communication is already configured under FactoryTalk Linx), just right click this new object on your display, and set the global object parameter values.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"430\" height=\"252\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/parameters.png\" alt=\"\" class=\"wp-image-2547 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/parameters.png 430w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/parameters-300x176.png 300w\" data-sizes=\"(max-width: 430px) 100vw, 430px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 430px; --smush-placeholder-aspect-ratio: 430\/252;\" \/><\/figure>\n\n\n\n<p>Choose the Ellipsis to browse for the instruction&#8217;s tag.  In this case, it&#8217;s a program tag called P_Din_01.  Refresh all folders, then locate the P_Din_01 tag.  Click this tag, then press OK.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"727\" height=\"294\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-121.png\" alt=\"\" class=\"wp-image-3232 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-121.png 727w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-121-300x121.png 300w\" data-sizes=\"(max-width: 727px) 100vw, 727px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 727px; --smush-placeholder-aspect-ratio: 727\/294;\" \/><\/figure>\n\n\n\n<p>Be sure to set the Path (Parameter #103).  The path is the folder that contains the instruction&#8217;s instruction.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"425\" height=\"37\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-122.png\" alt=\"\" class=\"wp-image-3233 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-122.png 425w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-122-300x26.png 300w\" data-sizes=\"(max-width: 425px) 100vw, 425px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 425px; --smush-placeholder-aspect-ratio: 425\/37;\" \/><\/figure>\n\n\n\n<p>Save your display screen as &#8220;DIN&#8221;.    At last, we are ready to test the client.   Click the &#8220;Launch SE Client&#8221; icon in the standard toolbar.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"423\" height=\"82\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/launchclient.png\" alt=\"\" class=\"wp-image-2550 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/launchclient.png 423w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/launchclient-300x58.png 300w\" data-sizes=\"(max-width: 423px) 100vw, 423px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 423px; --smush-placeholder-aspect-ratio: 423\/82;\" \/><\/figure>\n\n\n\n<p>Create a new Client Configuration File.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"785\" height=\"167\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/createclient.png\" alt=\"\" class=\"wp-image-2551 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/createclient.png 785w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/createclient-300x64.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/createclient-768x163.png 768w\" data-sizes=\"(max-width: 785px) 100vw, 785px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 785px; --smush-placeholder-aspect-ratio: 785\/167;\" \/><\/figure>\n\n\n\n<p>In this case, we&#8217;ll leave the name (and path) at default.  Press Continue.  <\/p>\n\n\n\n<p>Under &#8220;Startup Components&#8221;, we&#8217;ll set the fields as shown.   Be sure to select your proper application type.  Sooner or later, we&#8217;ll set up a startup macro to organize the initial displays.  In the meantime, we&#8217;ll select the initial display as DIN.  Press &#8220;Save&#8221;, then &#8220;Run&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"923\" height=\"587\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/startupoptions.png\" alt=\"\" class=\"wp-image-2552 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/startupoptions.png 923w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/startupoptions-300x191.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/startupoptions-768x488.png 768w\" data-sizes=\"(max-width: 923px) 100vw, 923px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 923px; --smush-placeholder-aspect-ratio: 923\/587;\" \/><\/figure>\n\n\n\n<p>Your project is now running, and we are displaying the state of the input to the operator.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"244\" height=\"247\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/runtest.png\" alt=\"\" class=\"wp-image-2554 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 244px; --smush-placeholder-aspect-ratio: 244\/247;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Configure the Faceplate<\/h4>\n\n\n\n<p>Click the object, and go to Maintenance, Display Advanced Properties, and then to HMI Configuration. Configure the Label, Tag, and states. In this case, we want to display the text in the normal state (vs hiding the state text).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"651\" height=\"379\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/11\/image-1.png\" alt=\"\" class=\"wp-image-3266 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/11\/image-1.png 651w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/11\/image-1-300x175.png 300w\" data-sizes=\"(max-width: 651px) 100vw, 651px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 651px; --smush-placeholder-aspect-ratio: 651\/379;\" \/><\/figure>\n\n\n\n<p>On the &#8220;Maintenance&#8221; Tab, set a debounce time if needed. This ensures the instruction only sees one transition in a certain amount of time.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"361\" height=\"408\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/11\/image-2.png\" alt=\"\" class=\"wp-image-3267 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/11\/image-2.png 361w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/11\/image-2-265x300.png 265w\" data-sizes=\"(max-width: 361px) 100vw, 361px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 361px; --smush-placeholder-aspect-ratio: 361\/408;\" \/><\/figure>\n\n\n\n<p>The engineering tab allows you to use a substitute PV. You must be careful how you use this feature. For example, if you remove a limit switch, you might substitute a value of 1 temporarily.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"740\" height=\"375\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/11\/image-3.png\" alt=\"\" class=\"wp-image-3268 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/11\/image-3.png 740w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/11\/image-3-300x152.png 300w\" data-sizes=\"(max-width: 740px) 100vw, 740px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 740px; --smush-placeholder-aspect-ratio: 740\/375;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Observations<\/h4>\n\n\n\n<ul class=\"wp-block-list\"><li>To illustrate, turn the switch on and off.   You will see the state of the input change on the display screen.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"144\" height=\"49\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/dinoff.png\" alt=\"\" class=\"wp-image-2555 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 144px; --smush-placeholder-aspect-ratio: 144\/49;\" \/><\/figure>\n\n\n\n<ul class=\"wp-block-list\"><li>If the gate is on, and the input does not match the target, your object will turn black (instead of gray) to indicate a mismatch.<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"146\" height=\"48\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/gate.png\" alt=\"\" class=\"wp-image-2556 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 146px; --smush-placeholder-aspect-ratio: 146\/48;\" \/><\/figure>\n\n\n\n<p>For more information on PlantPAx, visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/plantpax\/\">PlantPAx category page!<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-1428702872\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to PlantPAx 4 Digital Input Instruction The PlantPAx 4 Digital Input instruction monitors discrete (digital) inputs in your system. The advantage of using a P_Din for each input is that we will display the status of the input for the operator. Another advantage is to ensure the switch has reached it&#8217;s target state. In <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":2546,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4,195],"tags":[51,198,196],"class_list":{"0":"post-2540","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-controllogix","8":"category-plantpax","9":"tag-factorytalk-view","10":"tag-p_din","11":"tag-plantpax","12":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>PlantPAx 4 Digital Input Instruction Instruction - Bryce Automation<\/title>\n<meta name=\"description\" content=\"How to import PlantPAx 4 Digital Input Add-On instruction in Studio 5000 and import and utilize the corresponding display object.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PlantPAx 4 Digital Input Instruction Instruction - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"How to import PlantPAx 4 Digital Input Add-On instruction in Studio 5000 and import and utilize the corresponding display object.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-08-11T14:15:45+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-11-15T21:05:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/globalpdin.png\" \/>\n\t<meta property=\"og:image:width\" content=\"717\" \/>\n\t<meta property=\"og:image:height\" content=\"472\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"PlantPAx 4 Digital Input Instruction\",\"datePublished\":\"2020-08-11T14:15:45+00:00\",\"dateModified\":\"2020-11-15T21:05:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/\"},\"wordCount\":724,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/globalpdin.png\",\"keywords\":[\"FactoryTalk View\",\"P_Din\",\"PlantPAx\"],\"articleSection\":[\"ControlLogix\",\"PlantPAx\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/\",\"name\":\"PlantPAx 4 Digital Input Instruction Instruction - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/globalpdin.png\",\"datePublished\":\"2020-08-11T14:15:45+00:00\",\"dateModified\":\"2020-11-15T21:05:09+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"How to import PlantPAx 4 Digital Input Add-On instruction in Studio 5000 and import and utilize the corresponding display object.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/globalpdin.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/globalpdin.png\",\"width\":717,\"height\":472,\"caption\":\"Drag P_DIn\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/11\\\/plantpax-4-digital-input\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PlantPAx 4 Digital Input Instruction\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PlantPAx 4 Digital Input Instruction Instruction - Bryce Automation","description":"How to import PlantPAx 4 Digital Input Add-On instruction in Studio 5000 and import and utilize the corresponding display object.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/","og_locale":"en_US","og_type":"article","og_title":"PlantPAx 4 Digital Input Instruction Instruction - Bryce Automation","og_description":"How to import PlantPAx 4 Digital Input Add-On instruction in Studio 5000 and import and utilize the corresponding display object.","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-08-11T14:15:45+00:00","article_modified_time":"2020-11-15T21:05:09+00:00","og_image":[{"width":717,"height":472,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/globalpdin.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"PlantPAx 4 Digital Input Instruction","datePublished":"2020-08-11T14:15:45+00:00","dateModified":"2020-11-15T21:05:09+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/"},"wordCount":724,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/globalpdin.png","keywords":["FactoryTalk View","P_Din","PlantPAx"],"articleSection":["ControlLogix","PlantPAx"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/","name":"PlantPAx 4 Digital Input Instruction Instruction - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/globalpdin.png","datePublished":"2020-08-11T14:15:45+00:00","dateModified":"2020-11-15T21:05:09+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"How to import PlantPAx 4 Digital Input Add-On instruction in Studio 5000 and import and utilize the corresponding display object.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/globalpdin.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/globalpdin.png","width":717,"height":472,"caption":"Drag P_DIn"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/11\/plantpax-4-digital-input\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"PlantPAx 4 Digital Input Instruction"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2540","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=2540"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2540\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/2546"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=2540"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=2540"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=2540"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}