{"id":2642,"date":"2020-08-12T20:19:36","date_gmt":"2020-08-12T20:19:36","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=2642"},"modified":"2020-08-12T20:29:37","modified_gmt":"2020-08-12T20:29:37","slug":"beginning-a-factorytalk-view-se-project","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/","title":{"rendered":"Beginning a FactoryTalk View SE Project"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Introduction to beginning a FactoryTalk View SE project.<\/h3>\n\n\n\n<p>FactoryTalk view is HMI (Human-Machine Interface Software).  This software allows you to set up objects on a screen that interact with memory location in the equipment&#8217;s processor.  The first thing you might notice when beginning a FactoryTalk View SE Project is that something appears to be missing.  Specifically, there are no HMI displays, Alarm Server, or Communication server in the new project.  You will especially notice this if you are used to FactoryTalk View ME.  Through this post, I will walk through the steps of getting these servers installed, and how to set them up.  In this case, we&#8217;ll just create a simple project that displays a &#8220;Hello World&#8221; screen.  Other posts on this site will discuss how to add other objects on a display to interact with the PLC.  I&#8217;m using version 11.   If you need to upgrade your software, and are in support, visit the <a href=\"https:\/\/compatibility.rockwellautomation.com\/Pages\/home.aspx\">Rockwell Automation<\/a> website.<\/p><div id=\"bryce-141105838\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Create a new project<\/h3>\n\n\n\n<p>Let&#8217;s start off by opening FactoryTalk View SE.  Notice we have several options for our project.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"663\" height=\"444\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/ftstart.png\" alt=\"\" class=\"wp-image-2643 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/ftstart.png 663w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/ftstart-300x201.png 300w\" data-sizes=\"(max-width: 663px) 100vw, 663px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 663px; --smush-placeholder-aspect-ratio: 663\/444;\" \/><\/figure>\n\n\n\n<p>Network distributed is for different services to be running on different servers of your network.   In contrast, for a network station, your services will all run on one server of  your network.  For a local station, everything will run on the same computer.  The last option, Machine Edition is a different software package that allows you to program a PanelView Plus terminal.  <\/p>\n\n\n\n<p>In this case, I&#8217;ll just choose &#8220;Network Station&#8221;, then press &#8220;Continue&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"563\" height=\"449\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/secreate.png\" alt=\"\" class=\"wp-image-2644 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/secreate.png 563w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/secreate-300x239.png 300w\" data-sizes=\"(max-width: 563px) 100vw, 563px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 563px; --smush-placeholder-aspect-ratio: 563\/449;\" \/><\/figure>\n\n\n\n<p>As I have said, the Explorer Tree has few options.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"280\" height=\"269\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/blankexplorer.png\" alt=\"\" class=\"wp-image-2646 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 280px; --smush-placeholder-aspect-ratio: 280\/269;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Add the HMI Server<\/h4>\n\n\n\n<p>First, let&#8217;s add the HMI Server.  I&#8217;m going to right-click on the name of the project.  This is called &#8220;MyTest&#8221;.  Choose &#8220;Add New Server&#8221;, then &#8220;HMI Server&#8221;.  Choose to &#8220;Create a New HMI Server&#8221;, then click &#8220;Next&#8221;.  I will call this &#8220;MyHMIServer&#8221;, then click &#8220;Finish&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"627\" height=\"425\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/MyHMIServer.png\" alt=\"\" class=\"wp-image-2647 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/MyHMIServer.png 627w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/MyHMIServer-300x203.png 300w\" data-sizes=\"(max-width: 627px) 100vw, 627px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 627px; --smush-placeholder-aspect-ratio: 627\/425;\" \/><\/figure>\n\n\n\n<p>I&#8217;m not going to use any of the default displays in this project.   I selected &#8220;Clear All&#8221;, then press &#8220;OK&#8221;.<\/p>\n\n\n\n<p>At this point, you will notice we have a lot more folders in the Explorer tree.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"423\" height=\"160\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/newdisplay.png\" alt=\"\" class=\"wp-image-2648 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/newdisplay.png 423w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/newdisplay-300x113.png 300w\" data-sizes=\"(max-width: 423px) 100vw, 423px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 423px; --smush-placeholder-aspect-ratio: 423\/160;\" \/><\/figure>\n\n\n\n<p>At any rate, We&#8217;ll just add the text &#8220;Hello World&#8221; to the screen, and close the display screen.  When we close the display, name it &#8220;Main&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"384\" height=\"148\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/helloworld.png\" alt=\"\" class=\"wp-image-2649 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/helloworld.png 384w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/helloworld-300x116.png 300w\" data-sizes=\"(max-width: 384px) 100vw, 384px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 384px; --smush-placeholder-aspect-ratio: 384\/148;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Add the Communication Server<\/h3>\n\n\n\n<p>At this point, we are ready to add the FactoryTalk Linx communication server.  If you have a special need, you can also add the RSLinx OPC server.<\/p>\n\n\n\n<p>Right-click the name of the project, &#8220;MyTest&#8221;.  Choose &#8220;Add New Server&#8221;.  Specifically, for this project, choose &#8220;Rockwell Automation Device Server&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"703\" height=\"224\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addftserver.png\" alt=\"\" class=\"wp-image-2652 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addftserver.png 703w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addftserver-300x96.png 300w\" data-sizes=\"(max-width: 703px) 100vw, 703px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 703px; --smush-placeholder-aspect-ratio: 703\/224;\" \/><\/figure>\n\n\n\n<p>After that, we&#8217;ll leave the next dialog box at default, and press &#8220;OK&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"492\" height=\"669\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/adddeviceserver.png\" alt=\"\" class=\"wp-image-2653 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/adddeviceserver.png 492w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/adddeviceserver-221x300.png 221w\" data-sizes=\"(max-width: 492px) 100vw, 492px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 492px; --smush-placeholder-aspect-ratio: 492\/669;\" \/><\/figure>\n\n\n\n<p>At last, we&#8217;ll configure the communication path.  Under FactoryTalk Linx, open &#8220;Communication Setup&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"399\" height=\"154\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/communicationsetup.png\" alt=\"\" class=\"wp-image-2654 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/communicationsetup.png 399w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/communicationsetup-300x116.png 300w\" data-sizes=\"(max-width: 399px) 100vw, 399px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 399px; --smush-placeholder-aspect-ratio: 399\/154;\" \/><\/figure>\n\n\n\n<p>Let&#8217;s add a device shortcut called PLC.  Be sure this shortcut points to your PROCESSOR!  When finished, press &#8220;Apply&#8221; then OK.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Add the Alarm and Events Server<\/h3>\n\n\n\n<p>If you need alarms in your project, at this point, we will add the alarm and event server to your project.  With this purpose in mind, right-click the project name &#8220;My Test&#8221;.  Choose to &#8220;Add New Server&#8221;, then choose &#8220;Tag Alarm and Event Server&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"553\" height=\"230\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addaeserver.png\" alt=\"\" class=\"wp-image-2656 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addaeserver.png 553w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addaeserver-300x125.png 300w\" data-sizes=\"(max-width: 553px) 100vw, 553px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 553px; --smush-placeholder-aspect-ratio: 553\/230;\" \/><\/figure>\n\n\n\n<p>We&#8217;ll just name it &#8220;AEServer&#8221;, then click OK.<\/p>\n\n\n\n<p>Congratulations!   Your project is now started.   You are ready to add other graphic displays, alarms, or other features of FactoryTalk View SE.<\/p>\n\n\n\n<p>If you need information about FactoryTalk View ME, visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/factorytalk-view-me\/\">FactoryTalk View ME Category Page!<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-3032511166\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to beginning a FactoryTalk View SE project. FactoryTalk view is HMI (Human-Machine Interface Software). This software allows you to set up objects on a screen that interact with memory location in the equipment&#8217;s processor. The first thing you might notice when beginning a FactoryTalk View SE Project is that something appears to be missing. <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":2643,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[205,195],"tags":[197,206],"class_list":{"0":"post-2642","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-factorytalk-view-se","8":"category-plantpax","9":"tag-factorytalk-view-se","10":"tag-start-hmi-project","11":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Beginning a FactoryTalk View SE Project - Bryce Automation<\/title>\n<meta name=\"description\" content=\"Beginning a FactoryTalk view SE Project: We will add the HMI Server, Communication Server, and Alarm and Events Server.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Beginning a FactoryTalk View SE Project - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"Beginning a FactoryTalk view SE Project: We will add the HMI Server, Communication Server, and Alarm and Events Server.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-08-12T20:19:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-08-12T20:29:37+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/ftstart.png\" \/>\n\t<meta property=\"og:image:width\" content=\"663\" \/>\n\t<meta property=\"og:image:height\" content=\"444\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"Beginning a FactoryTalk View SE Project\",\"datePublished\":\"2020-08-12T20:19:36+00:00\",\"dateModified\":\"2020-08-12T20:29:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/\"},\"wordCount\":586,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/ftstart.png\",\"keywords\":[\"FactoryTalk View SE\",\"Start HMI Project\"],\"articleSection\":[\"FactoryTalk View SE\",\"PlantPAx\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/\",\"name\":\"Beginning a FactoryTalk View SE Project - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/ftstart.png\",\"datePublished\":\"2020-08-12T20:19:36+00:00\",\"dateModified\":\"2020-08-12T20:29:37+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"Beginning a FactoryTalk view SE Project: We will add the HMI Server, Communication Server, and Alarm and Events Server.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/ftstart.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/ftstart.png\",\"width\":663,\"height\":444},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/12\\\/beginning-a-factorytalk-view-se-project\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Beginning a FactoryTalk View SE Project\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Beginning a FactoryTalk View SE Project - Bryce Automation","description":"Beginning a FactoryTalk view SE Project: We will add the HMI Server, Communication Server, and Alarm and Events Server.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/","og_locale":"en_US","og_type":"article","og_title":"Beginning a FactoryTalk View SE Project - Bryce Automation","og_description":"Beginning a FactoryTalk view SE Project: We will add the HMI Server, Communication Server, and Alarm and Events Server.","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-08-12T20:19:36+00:00","article_modified_time":"2020-08-12T20:29:37+00:00","og_image":[{"width":663,"height":444,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/ftstart.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"Beginning a FactoryTalk View SE Project","datePublished":"2020-08-12T20:19:36+00:00","dateModified":"2020-08-12T20:29:37+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/"},"wordCount":586,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/ftstart.png","keywords":["FactoryTalk View SE","Start HMI Project"],"articleSection":["FactoryTalk View SE","PlantPAx"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/","name":"Beginning a FactoryTalk View SE Project - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/ftstart.png","datePublished":"2020-08-12T20:19:36+00:00","dateModified":"2020-08-12T20:29:37+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"Beginning a FactoryTalk view SE Project: We will add the HMI Server, Communication Server, and Alarm and Events Server.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/ftstart.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/ftstart.png","width":663,"height":444},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/beginning-a-factorytalk-view-se-project\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"Beginning a FactoryTalk View SE Project"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2642","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=2642"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2642\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/2643"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=2642"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=2642"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=2642"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}