{"id":2688,"date":"2020-08-13T13:44:37","date_gmt":"2020-08-13T13:44:37","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=2688"},"modified":"2020-11-15T15:00:13","modified_gmt":"2020-11-15T15:00:13","slug":"plantpax-4-1-motor-operated-valve","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/","title":{"rendered":"PlantPAx 4 Motor Operated Valve"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Introduction to PlantPAx 4 Motor Operated Valve<\/h3>\n\n\n\n<p>The PlantPAx 4 Motor Operated Valve instructions allows us to open or close a valve.    Additionally, it provides some diagnostic information about the valve.  That is, we will get an alarm if the valve fails to open or shut.   Even if we get a switch failure (such as both switches being made), the operator is informed of the problem.<\/p><div id=\"bryce-2162109737\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Add the logic<\/h3>\n\n\n\n<p>To begin, let&#8217;s import the P_ValveMO add-on instruction.   Later on, we will use this instruction in logic to control the valve, and to view it&#8217;s status.<\/p>\n\n\n\n<p>Right-click &#8220;Add-On Instructions&#8221;, and &#8220;Import Add-On Instruction&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"415\" height=\"87\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addon-1.png\" alt=\"\" class=\"wp-image-2542 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addon-1.png 415w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addon-1-300x63.png 300w\" data-sizes=\"(max-width: 415px) 100vw, 415px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 415px; --smush-placeholder-aspect-ratio: 415\/87;\" \/><\/figure>\n\n\n\n<p>Select the P_ValveMO add-on instruction, the click OK.    <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"871\" height=\"574\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/importmovalve.png\" alt=\"\" class=\"wp-image-2689 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/importmovalve.png 871w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/importmovalve-300x198.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/importmovalve-768x506.png 768w\" data-sizes=\"(max-width: 871px) 100vw, 871px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 871px; --smush-placeholder-aspect-ratio: 871\/574;\" \/><\/figure>\n\n\n\n<p>Just leave the instruction at default settings when you import.  In this case, I&#8217;ve created a subroutine for the valve.   The Subroutine is a function block type.   It&#8217;s important to realize that you must jump to this subroutine with a JSR statement.<\/p>\n\n\n\n<p>At this point, add the instruction onto your function bock.   Click the Ellipsis to configure the instruction&#8217;s parameters.   Be sure to make PCmd_Open, and PCmd_Close visible, then press OK.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"654\" height=\"571\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/pcmdvalve.png\" alt=\"\" class=\"wp-image-2690 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/pcmdvalve.png 654w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/pcmdvalve-300x262.png 300w\" data-sizes=\"(max-width: 654px) 100vw, 654px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 654px; --smush-placeholder-aspect-ratio: 654\/571;\" \/><\/figure>\n\n\n\n<p>At this time, since we are not using interlocks and permissives yet, go into the configuration of the object (using the ellipsis).   Set the following tags to the value of 1 as shown.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"755\" height=\"529\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/intlkok.png\" alt=\"\" class=\"wp-image-2700 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/intlkok.png 755w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/intlkok-300x210.png 300w\" data-sizes=\"(max-width: 755px) 100vw, 755px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 755px; --smush-placeholder-aspect-ratio: 755\/529;\" \/><\/figure>\n\n\n\n<p>Let&#8217;s also add 4 Input references and 2 output references as seen below.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"725\" height=\"557\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/movinstructionfinished.png\" alt=\"\" class=\"wp-image-2692 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/movinstructionfinished.png 725w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/movinstructionfinished-300x230.png 300w\" data-sizes=\"(max-width: 725px) 100vw, 725px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 725px; --smush-placeholder-aspect-ratio: 725\/557;\" \/><\/figure>\n\n\n\n<p>As you can see, FlexSwitch.4 and FlexSwitch.5 will act as our open and closed Limit Switches.  Of course, FlexLight.4 and FlexLight.5 will simulate the open and close outputs to the valve.  FlexSwitch.6 and FlexSwitch.7 will be our commands to control the valve while we are in Program Control Mode.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Import the Faceplates<\/h3>\n\n\n\n<p>Next, back in FactoryTalk View SE, right click &#8220;Displays&#8221; under graphics, and &#8220;Add Component into Application&#8221;.<\/p>\n\n\n\n<p>At this point, we will hold the CTRL key, and select P_ValveMO-Advanced, P_ValveMO-Faceplate, P_ValveMO-Quick, P_ValveStats-Advanced, and P_ValveStats-Faceplate.  When finished selecting the objects, click &#8220;Open&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"587\" height=\"336\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/11\/image.png\" alt=\"\" class=\"wp-image-3248 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/11\/image.png 587w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/11\/image-300x172.png 300w\" data-sizes=\"(max-width: 587px) 100vw, 587px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 587px; --smush-placeholder-aspect-ratio: 587\/336;\" \/><\/figure>\n\n\n\n<p>Finally, lets add the PlantPAx4.1 Motor Operated Valve instruction onto our display.   You will find this object in the Process Graphics Library.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"937\" height=\"453\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addvalvemo.png\" alt=\"\" class=\"wp-image-2696 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addvalvemo.png 937w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addvalvemo-300x145.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addvalvemo-768x371.png 768w\" data-sizes=\"(max-width: 937px) 100vw, 937px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 937px; --smush-placeholder-aspect-ratio: 937\/453;\" \/><\/figure>\n\n\n\n<p>Be sure to right click this new object and set the global object parameter values.  Parameter #102 will point to our tag for the valve in logic.   Parameter #103 is the path for the object to locate other instructions such as <a href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/plantpax-4-1-permissives\/\">permissives <\/a>and <a href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/12\/plantpax-4-1-interlocks\/\">interlocks<\/a>.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"741\" height=\"439\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/setvalveparams.png\" alt=\"\" class=\"wp-image-2698 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/setvalveparams.png 741w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/setvalveparams-300x178.png 300w\" data-sizes=\"(max-width: 741px) 100vw, 741px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 741px; --smush-placeholder-aspect-ratio: 741\/439;\" \/><\/figure>\n\n\n\n<p>At this point, close your screen and save.  Be sure you have a way to get to this display, and a way to log in.  Launch the SE client.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"423\" height=\"82\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/launchclient.png\" alt=\"\" class=\"wp-image-2550 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/launchclient.png 423w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/launchclient-300x58.png 300w\" data-sizes=\"(max-width: 423px) 100vw, 423px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 423px; --smush-placeholder-aspect-ratio: 423\/82;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Using the display object<\/h3>\n\n\n\n<p>Be sure to log in to the client, and navigate to your display screen for the valve object.<\/p>\n\n\n\n<p>Next, go into Maintenance, Display advanced properties, and set up the timeouts as shown for this example.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"533\" height=\"323\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/motimeouts.png\" alt=\"\" class=\"wp-image-2701 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/motimeouts.png 533w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/motimeouts-300x182.png 300w\" data-sizes=\"(max-width: 533px) 100vw, 533px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 533px; --smush-placeholder-aspect-ratio: 533\/323;\" \/><\/figure>\n\n\n\n<p>At this point, go to the Engineering tab.   Declare that the valve has an open and closed limit switch.   Depending on how the switches are wired, we need to set the fault state.   For this example, we will set a fault state when both switches are 1.   Also, check that the operator can reset a fault.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"370\" height=\"490\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/valveengineering-1.png\" alt=\"\" class=\"wp-image-2703 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/valveengineering-1.png 370w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/valveengineering-1-227x300.png 227w\" data-sizes=\"(max-width: 370px) 100vw, 370px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 370px; --smush-placeholder-aspect-ratio: 370\/490;\" \/><\/figure>\n\n\n\n<p>On the HMI Configuration tab, document the tag&#8217;s label and tag.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"363\" height=\"409\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/ValveHMIConfig.png\" alt=\"\" class=\"wp-image-2704 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/ValveHMIConfig.png 363w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/ValveHMIConfig-266x300.png 266w\" data-sizes=\"(max-width: 363px) 100vw, 363px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 363px; --smush-placeholder-aspect-ratio: 363\/409;\" \/><\/figure>\n\n\n\n<p>Finally, back on the Maintenance tab, check that we will use the limit switches for faults checking.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"412\" height=\"346\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/valvemaintenance.png\" alt=\"\" class=\"wp-image-2705 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/valvemaintenance.png 412w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/valvemaintenance-300x252.png 300w\" data-sizes=\"(max-width: 412px) 100vw, 412px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 412px; --smush-placeholder-aspect-ratio: 412\/346;\" \/><\/figure>\n\n\n\n<p>At last, you are ready to launch the client, and test your work.  Use the operator commands to open and close the valve.  Put the valve into program control mode.  Use the switches on your station to issue an open command, then toggle the open limit switch to ensure the valve has opened.  Likewise, do the same with the close command.  Try to open or close the valve without toggling the limit switches.   Explore the faceplates to identify the fault condition, and to reset the fault.<\/p>\n\n\n\n<p>For more information, visit the PlantPAx <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/plantpax\/\">category page!<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-2765197334\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to PlantPAx 4 Motor Operated Valve The PlantPAx 4 Motor Operated Valve instructions allows us to open or close a valve. Additionally, it provides some diagnostic information about the valve. That is, we will get an alarm if the valve fails to open or shut. Even if we get a switch failure (such as <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":2696,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[195],"tags":[208,196],"class_list":{"0":"post-2688","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-plantpax","8":"tag-p_valvemo","9":"tag-plantpax","10":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>PlantPAx 4 Motor Operated Valve (P_ValveMO) - Bryce Automation<\/title>\n<meta name=\"description\" content=\"We will set up and configure a PlantPAx 4 motor operated valve in logic as well as import and configure the faceplates for PlantPAX.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PlantPAx 4 Motor Operated Valve (P_ValveMO) - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"We will set up and configure a PlantPAx 4 motor operated valve in logic as well as import and configure the faceplates for PlantPAX.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-08-13T13:44:37+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-11-15T15:00:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addvalvemo.png\" \/>\n\t<meta property=\"og:image:width\" content=\"937\" \/>\n\t<meta property=\"og:image:height\" content=\"453\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"PlantPAx 4 Motor Operated Valve\",\"datePublished\":\"2020-08-13T13:44:37+00:00\",\"dateModified\":\"2020-11-15T15:00:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/\"},\"wordCount\":646,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/addvalvemo.png\",\"keywords\":[\"P_ValveMO\",\"PlantPAx\"],\"articleSection\":[\"PlantPAx\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/\",\"name\":\"PlantPAx 4 Motor Operated Valve (P_ValveMO) - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/addvalvemo.png\",\"datePublished\":\"2020-08-13T13:44:37+00:00\",\"dateModified\":\"2020-11-15T15:00:13+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"We will set up and configure a PlantPAx 4 motor operated valve in logic as well as import and configure the faceplates for PlantPAX.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/addvalvemo.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/addvalvemo.png\",\"width\":937,\"height\":453},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/13\\\/plantpax-4-1-motor-operated-valve\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PlantPAx 4 Motor Operated Valve\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PlantPAx 4 Motor Operated Valve (P_ValveMO) - Bryce Automation","description":"We will set up and configure a PlantPAx 4 motor operated valve in logic as well as import and configure the faceplates for PlantPAX.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/","og_locale":"en_US","og_type":"article","og_title":"PlantPAx 4 Motor Operated Valve (P_ValveMO) - Bryce Automation","og_description":"We will set up and configure a PlantPAx 4 motor operated valve in logic as well as import and configure the faceplates for PlantPAX.","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-08-13T13:44:37+00:00","article_modified_time":"2020-11-15T15:00:13+00:00","og_image":[{"width":937,"height":453,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addvalvemo.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"PlantPAx 4 Motor Operated Valve","datePublished":"2020-08-13T13:44:37+00:00","dateModified":"2020-11-15T15:00:13+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/"},"wordCount":646,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addvalvemo.png","keywords":["P_ValveMO","PlantPAx"],"articleSection":["PlantPAx"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/","name":"PlantPAx 4 Motor Operated Valve (P_ValveMO) - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addvalvemo.png","datePublished":"2020-08-13T13:44:37+00:00","dateModified":"2020-11-15T15:00:13+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"We will set up and configure a PlantPAx 4 motor operated valve in logic as well as import and configure the faceplates for PlantPAX.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addvalvemo.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/addvalvemo.png","width":937,"height":453},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/13\/plantpax-4-1-motor-operated-valve\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"PlantPAx 4 Motor Operated Valve"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2688","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=2688"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2688\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/2696"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=2688"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=2688"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=2688"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}