{"id":2934,"date":"2020-08-29T10:29:55","date_gmt":"2020-08-29T10:29:55","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=2934"},"modified":"2020-08-29T12:59:13","modified_gmt":"2020-08-29T12:59:13","slug":"slc-500-advanced-diagnostics","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/","title":{"rendered":"SLC-500 Advanced Diagnostics"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Introduction to SLC-500 Advanced Diagnostics<\/h3>\n\n\n\n<p>The SLC-500 Advanced Diagnostics feature allows you to quickly locate an output in your SLC-500 Project.  This is most effective if the project is organized, and documented well.   Instead of randomly searching through logic to find your output, you will be able to find them in an orderly manner.   Basically, Advanced Diagnostics asks 3 questions to narrow  your search.   This feature will ask in what routine your logic is located, what section of that routine, and lastly, what output in that section you wish to navigate to.<\/p><div id=\"bryce-3206061847\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading\">A Practical Example<\/h3>\n\n\n\n<p>In this example, we are going to search for a way to clear a process pressure failure alarm.   This is a chill water system.  We&#8217;ll use advanced diagnostics to find the output.   Once we find the output, we can look at the conditions on that rung.   This will tell us the reason that our failure bit will not clear.  We&#8217;ll assume that we&#8217;ve already fixed the problem causing the low pressure, and now we are just read to clear the alarm.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"804\" height=\"525\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-29.png\" alt=\"\" class=\"wp-image-2935 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-29.png 804w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-29-300x196.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-29-768x501.png 768w\" data-sizes=\"(max-width: 804px) 100vw, 804px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 804px; --smush-placeholder-aspect-ratio: 804\/525;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Starting Advanced Diagnostics<\/h4>\n\n\n\n<p>From the menu bar in RSLogix 500, click on Search | Advanced Diagnostics.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"433\" height=\"217\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-30.png\" alt=\"\" class=\"wp-image-2936 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-30.png 433w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-30-300x150.png 300w\" data-sizes=\"(max-width: 433px) 100vw, 433px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 433px; --smush-placeholder-aspect-ratio: 433\/217;\" \/><\/figure>\n\n\n\n<p>At this time, RSLogix 500 will ask what routine we wish to find the output in.   Since this is a failure alarm on the process pump, we&#8217;ll double-click the &#8220;pumps&#8221; routine.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"657\" height=\"501\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-31.png\" alt=\"\" class=\"wp-image-2937 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-31.png 657w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-31-300x229.png 300w\" data-sizes=\"(max-width: 657px) 100vw, 657px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 657px; --smush-placeholder-aspect-ratio: 657\/501;\" \/><\/figure>\n\n\n\n<p>Next, we see that page titles that are in this routine.   In RSLogix 500, the programmer adds Page Titles to mark sections of logic.  In this case, we need to &#8220;Clear Pressure Failure Bits&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"663\" height=\"506\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-32.png\" alt=\"\" class=\"wp-image-2938 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-32.png 663w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-32-300x229.png 300w\" data-sizes=\"(max-width: 663px) 100vw, 663px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 663px; --smush-placeholder-aspect-ratio: 663\/506;\" \/><\/figure>\n\n\n\n<p>At last, we will choose the output type instruction that we are looking for.  In this example, we have a OTU (Output to Unlatch) instruction that will shut off the process pressure failure bits.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"658\" height=\"503\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-34.png\" alt=\"\" class=\"wp-image-2940 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-34.png 658w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-34-300x229.png 300w\" data-sizes=\"(max-width: 658px) 100vw, 658px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 658px; --smush-placeholder-aspect-ratio: 658\/503;\" \/><\/figure>\n\n\n\n<p>Advanced diagnostics takes us to the output in logic.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"623\" height=\"383\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-36.png\" alt=\"\" class=\"wp-image-2942 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-36.png 623w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-36-300x184.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-36-570x350.png 570w\" data-sizes=\"(max-width: 623px) 100vw, 623px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 623px; --smush-placeholder-aspect-ratio: 623\/383;\" \/><\/figure>\n\n\n\n<p>At any rate, by looking at this rung we can see what we need to do to unlatch the process pressure failure bit.   First, we have to NOT be in auto.  In other words, we will go to manual mode.   Next, one of the pumps must be engaged, and we will need to have at least 51 lbs of pressure.   Finally, just wait for 10 seconds.    Remember for timers in the SLC, you must take the preset times the time base, and that is the number of seconds for the delay.<\/p>\n\n\n\n<p>If you ever need to navigate away from this rung, and need to come back&#8230;   Write down the ladder number, and rung number that we are in.   After that, you can just click Search | Goto, and enter the ladder and rung, and immediately return to this position.  When using the goto utility, your search is in ladder:rung format.   In other words, if you want to go to ladder 10, rung 2, you would enter &#8220;10:2&#8221; in the Search | Goto box.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Integrating Advanced Diagnostics into the project tree.<\/h3>\n\n\n\n<p>To make your job even easier, you can integrate advanced diagnostics into the project tree.  To do this click on Tools | Options in the menu bar.  Check &#8220;Integrate Advanced Diagnostics into the Project Tree.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"672\" height=\"657\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/integratead.png\" alt=\"\" class=\"wp-image-2943 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/integratead.png 672w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/integratead-300x293.png 300w\" data-sizes=\"(max-width: 672px) 100vw, 672px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 672px; --smush-placeholder-aspect-ratio: 672\/657;\" \/><\/figure>\n\n\n\n<p>Now, you can navigate through the page titles in the project tree.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"936\" height=\"612\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-37.png\" alt=\"\" class=\"wp-image-2944 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-37.png 936w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-37-300x196.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-37-768x502.png 768w\" data-sizes=\"(max-width: 936px) 100vw, 936px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 936px; --smush-placeholder-aspect-ratio: 936\/612;\" \/><\/figure>\n\n\n\n<p>For more information, visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/slc500\/\">SLC-500 Category Page.<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n\n\n\n<p><\/p>\n<div id=\"bryce-3310655272\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to SLC-500 Advanced Diagnostics The SLC-500 Advanced Diagnostics feature allows you to quickly locate an output in your SLC-500 Project. This is most effective if the project is organized, and documented well. Instead of randomly searching through logic to find your output, you will be able to find them in an orderly manner. Basically, <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":2935,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[130],"tags":[229,133,131,184],"class_list":{"0":"post-2934","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-slc500","8":"tag-advanced-diagnostics","9":"tag-slc-500","10":"tag-slc500","11":"tag-troubleshooting","12":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SLC-500 Advanced Diagnostics - Bryce Automation<\/title>\n<meta name=\"description\" content=\"How to use SLC-500 Advanced diagnostics. We will use Advanced diagnostics to navigate through the routine, page titles, and to the output.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SLC-500 Advanced Diagnostics - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"How to use SLC-500 Advanced diagnostics. We will use Advanced diagnostics to navigate through the routine, page titles, and to the output.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-08-29T10:29:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-08-29T12:59:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-29.png\" \/>\n\t<meta property=\"og:image:width\" content=\"804\" \/>\n\t<meta property=\"og:image:height\" content=\"525\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"SLC-500 Advanced Diagnostics\",\"datePublished\":\"2020-08-29T10:29:55+00:00\",\"dateModified\":\"2020-08-29T12:59:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/\"},\"wordCount\":533,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/image-29.png\",\"keywords\":[\"Advanced Diagnostics\",\"SLC-500\",\"SLC500\",\"Troubleshooting\"],\"articleSection\":[\"SLC500\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/\",\"name\":\"SLC-500 Advanced Diagnostics - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/image-29.png\",\"datePublished\":\"2020-08-29T10:29:55+00:00\",\"dateModified\":\"2020-08-29T12:59:13+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"How to use SLC-500 Advanced diagnostics. We will use Advanced diagnostics to navigate through the routine, page titles, and to the output.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/image-29.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/image-29.png\",\"width\":804,\"height\":525},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/29\\\/slc-500-advanced-diagnostics\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"SLC-500 Advanced Diagnostics\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SLC-500 Advanced Diagnostics - Bryce Automation","description":"How to use SLC-500 Advanced diagnostics. We will use Advanced diagnostics to navigate through the routine, page titles, and to the output.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/","og_locale":"en_US","og_type":"article","og_title":"SLC-500 Advanced Diagnostics - Bryce Automation","og_description":"How to use SLC-500 Advanced diagnostics. We will use Advanced diagnostics to navigate through the routine, page titles, and to the output.","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-08-29T10:29:55+00:00","article_modified_time":"2020-08-29T12:59:13+00:00","og_image":[{"width":804,"height":525,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-29.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"SLC-500 Advanced Diagnostics","datePublished":"2020-08-29T10:29:55+00:00","dateModified":"2020-08-29T12:59:13+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/"},"wordCount":533,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-29.png","keywords":["Advanced Diagnostics","SLC-500","SLC500","Troubleshooting"],"articleSection":["SLC500"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/","name":"SLC-500 Advanced Diagnostics - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-29.png","datePublished":"2020-08-29T10:29:55+00:00","dateModified":"2020-08-29T12:59:13+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"How to use SLC-500 Advanced diagnostics. We will use Advanced diagnostics to navigate through the routine, page titles, and to the output.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-29.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-29.png","width":804,"height":525},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/29\/slc-500-advanced-diagnostics\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"SLC-500 Advanced Diagnostics"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2934","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=2934"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2934\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/2935"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=2934"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=2934"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=2934"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}