{"id":2988,"date":"2020-08-30T20:09:14","date_gmt":"2020-08-30T20:09:14","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=2988"},"modified":"2020-08-30T20:58:19","modified_gmt":"2020-08-30T20:58:19","slug":"rs232-to-dh-passthru","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/","title":{"rendered":"RS232 to DH+ Passthru"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Introduction to RS232 to DH+ Passthru on the SLC 5\/04<\/h3>\n\n\n\n<p>With RS232 to DH+ Passthru, we will connect through the serial port on a processor, and access the DH+ network.   With this in mind, another option would be the 1784-U2DHP.   However this device might cost around $2,000 to purchase.  In this case, we will simply use an existing processor to access the DH+ Network through a Serial cable.  The disadvantage of course is about half the speed of a typical DH+ network.   For example, this processor is connected to a DH+ network, and we have a NULL modem cable connected to Channel 0.   Note:  The recommended (proper) cable to use on DH+ is Belden 9463.  Remember this is just for example only.   Your application and safety considerations may be different, so always take all precautions.<\/p><div id=\"bryce-551734985\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"783\" height=\"471\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-58.png\" alt=\"\" class=\"wp-image-2989 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-58.png 783w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-58-300x180.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-58-768x462.png 768w\" data-sizes=\"(max-width: 783px) 100vw, 783px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 783px; --smush-placeholder-aspect-ratio: 783\/471;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Configure Channel 0<\/h3>\n\n\n\n<p>Under &#8220;Channel Configuration&#8221;, on the General tab, be sure channel 0 is in &#8220;System&#8221; mode.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"902\" height=\"555\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-59.png\" alt=\"\" class=\"wp-image-2991 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-59.png 902w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-59-300x185.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-59-768x473.png 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-59-570x350.png 570w\" data-sizes=\"(max-width: 902px) 100vw, 902px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 902px; --smush-placeholder-aspect-ratio: 902\/555;\" \/><\/figure>\n\n\n\n<p>On the &#8220;Channel 0 System&#8221; tab make note of the system settings.   We will need those later.  Obviously, the main parameters are 19,200 baud rate, no parity, and one stop bit.   Also remember our error detection mode is CRC.   It&#8217;s important to realize that when you hit &#8220;Apply&#8221; and &#8220;OK&#8221;, the processor must go to program mode to accept the changes.   Obviously, you will want to wait until your system is down to do this.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"678\" height=\"495\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-60.png\" alt=\"\" class=\"wp-image-2992 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-60.png 678w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-60-300x219.png 300w\" data-sizes=\"(max-width: 678px) 100vw, 678px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 678px; --smush-placeholder-aspect-ratio: 678\/495;\" \/><\/figure>\n\n\n\n<p>Our next step is to configure the passthru.  On the Processor Status file (S2 Data file), Disable DH485 Passthru, and enable RS232 passthru.  Be sure to hit enter.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"687\" height=\"364\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-63.png\" alt=\"\" class=\"wp-image-2995 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-63.png 687w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-63-300x159.png 300w\" data-sizes=\"(max-width: 687px) 100vw, 687px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 687px; --smush-placeholder-aspect-ratio: 687\/364;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Configure the RSLinx Driver<\/h3>\n\n\n\n<p>In RSLinx, go to Communication | Configure Drivers.   Choose the RS232 DF1 Device driver, then &#8220;Add New&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"827\" height=\"414\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-61.png\" alt=\"\" class=\"wp-image-2993 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-61.png 827w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-61-300x150.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-61-768x384.png 768w\" data-sizes=\"(max-width: 827px) 100vw, 827px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 827px; --smush-placeholder-aspect-ratio: 827\/414;\" \/><\/figure>\n\n\n\n<p>At this point, you will need to know the COM line that your serial cable is on.   In this case, I went to &#8220;Device Manager&#8221; under Windows, and found that my USB to Serial adapter is on COM 4.<\/p>\n\n\n\n<p>In this case, I chose the 1770-KF2 driver.   This is the device the 5\/04 is emulating.  Enter all other settings as we saw them on channel 0 &#8211; system&#8217;s configuration.  Note:   Autoconfiguration will not work, so be absolutely sure your settings are correct, then press OK.  If your settings are not correct, that will cause a lot of problems when  you try to browse the network later on.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"584\" height=\"530\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-62.png\" alt=\"\" class=\"wp-image-2994 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-62.png 584w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-62-300x272.png 300w\" data-sizes=\"(max-width: 584px) 100vw, 584px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 584px; --smush-placeholder-aspect-ratio: 584\/530;\" \/><\/figure>\n\n\n\n<p>Hit OK, then go to the RSWho Screen.   (Comms | RSWho).  Open your DF1 Driver.<\/p>\n\n\n\n<p>In my case, I was stuck on &#8220;Browsing Network&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"479\" height=\"213\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-66.png\" alt=\"\" class=\"wp-image-3002 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-66.png 479w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-66-300x133.png 300w\" data-sizes=\"(max-width: 479px) 100vw, 479px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 479px; --smush-placeholder-aspect-ratio: 479\/213;\" \/><\/figure>\n\n\n\n<p>Then, I went to the properties of the driver in RSWHo.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"528\" height=\"258\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-67.png\" alt=\"\" class=\"wp-image-3004 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-67.png 528w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-67-300x147.png 300w\" data-sizes=\"(max-width: 528px) 100vw, 528px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 528px; --smush-placeholder-aspect-ratio: 528\/258;\" \/><\/figure>\n\n\n\n<p>Then I configured the properties to browse node 0 to 63.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"399\" height=\"212\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-68.png\" alt=\"\" class=\"wp-image-3005 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-68.png 399w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-68-300x159.png 300w\" data-sizes=\"(max-width: 399px) 100vw, 399px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 399px; --smush-placeholder-aspect-ratio: 399\/212;\" \/><\/figure>\n\n\n\n<p>Under &#8220;Advanced Browse Settings, I forced the network type to DH+, then be sure to hit &#8220;Apply&#8221;, then &#8220;OK&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"537\" height=\"149\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-69.png\" alt=\"\" class=\"wp-image-3006 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-69.png 537w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-69-300x83.png 300w\" data-sizes=\"(max-width: 537px) 100vw, 537px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 537px; --smush-placeholder-aspect-ratio: 537\/149;\" \/><\/figure>\n\n\n\n<p>Next, I removed the DF1 Driver from RSWho (and only from the RSWho screen, not the driver configuration).<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"523\" height=\"239\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-70.png\" alt=\"\" class=\"wp-image-3007 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-70.png 523w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-70-300x137.png 300w\" data-sizes=\"(max-width: 523px) 100vw, 523px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 523px; --smush-placeholder-aspect-ratio: 523\/239;\" \/><\/figure>\n\n\n\n<p>Finally, I clicked on the Workstation, to let RSWho re-discover the driver.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"442\" height=\"218\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-71.png\" alt=\"\" class=\"wp-image-3008 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-71.png 442w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-71-300x148.png 300w\" data-sizes=\"(max-width: 442px) 100vw, 442px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 442px; --smush-placeholder-aspect-ratio: 442\/218;\" \/><\/figure>\n\n\n\n<p>At last, I opened the driver, and all of the nodes appeared.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1020\" height=\"338\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-65.png\" alt=\"\" class=\"wp-image-2997 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-65.png 1020w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-65-300x99.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-65-768x254.png 768w\" data-sizes=\"(max-width: 1020px) 100vw, 1020px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1020px; --smush-placeholder-aspect-ratio: 1020\/338;\" \/><\/figure>\n\n\n\n<p>For more information on the SLC, visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/slc500\/\">Category page.<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-2658202837\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to RS232 to DH+ Passthru on the SLC 5\/04 With RS232 to DH+ Passthru, we will connect through the serial port on a processor, and access the DH+ network. With this in mind, another option would be the 1784-U2DHP. However this device might cost around $2,000 to purchase. In this case, we will simply <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":2989,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[130],"tags":[237,236,235,42],"class_list":{"0":"post-2988","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-slc500","8":"tag-5-04","9":"tag-df1-to-dh","10":"tag-passthru","11":"tag-rslinx","12":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>RS232 to DH+ Passthru (Using the SLC 5\/04) - Bryce Automation<\/title>\n<meta name=\"description\" content=\"How to set up RS232 to DH+ Passthru on a 5\/04 processor. We&#039;ll walk through the channel config, Status File setup, and the RSLinx Driver.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"RS232 to DH+ Passthru (Using the SLC 5\/04) - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"How to set up RS232 to DH+ Passthru on a 5\/04 processor. We&#039;ll walk through the channel config, Status File setup, and the RSLinx Driver.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-08-30T20:09:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-08-30T20:58:19+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-58.png\" \/>\n\t<meta property=\"og:image:width\" content=\"783\" \/>\n\t<meta property=\"og:image:height\" content=\"471\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"RS232 to DH+ Passthru\",\"datePublished\":\"2020-08-30T20:09:14+00:00\",\"dateModified\":\"2020-08-30T20:58:19+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/\"},\"wordCount\":496,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/image-58.png\",\"keywords\":[\"5\\\/04\",\"DF1 to DH+\",\"Passthru\",\"RSLinx\"],\"articleSection\":[\"SLC500\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/\",\"name\":\"RS232 to DH+ Passthru (Using the SLC 5\\\/04) - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/image-58.png\",\"datePublished\":\"2020-08-30T20:09:14+00:00\",\"dateModified\":\"2020-08-30T20:58:19+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"How to set up RS232 to DH+ Passthru on a 5\\\/04 processor. We'll walk through the channel config, Status File setup, and the RSLinx Driver.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/image-58.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/08\\\/image-58.png\",\"width\":783,\"height\":471},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/08\\\/30\\\/rs232-to-dh-passthru\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"RS232 to DH+ Passthru\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"RS232 to DH+ Passthru (Using the SLC 5\/04) - Bryce Automation","description":"How to set up RS232 to DH+ Passthru on a 5\/04 processor. We'll walk through the channel config, Status File setup, and the RSLinx Driver.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/","og_locale":"en_US","og_type":"article","og_title":"RS232 to DH+ Passthru (Using the SLC 5\/04) - Bryce Automation","og_description":"How to set up RS232 to DH+ Passthru on a 5\/04 processor. We'll walk through the channel config, Status File setup, and the RSLinx Driver.","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-08-30T20:09:14+00:00","article_modified_time":"2020-08-30T20:58:19+00:00","og_image":[{"width":783,"height":471,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-58.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"RS232 to DH+ Passthru","datePublished":"2020-08-30T20:09:14+00:00","dateModified":"2020-08-30T20:58:19+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/"},"wordCount":496,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-58.png","keywords":["5\/04","DF1 to DH+","Passthru","RSLinx"],"articleSection":["SLC500"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/","name":"RS232 to DH+ Passthru (Using the SLC 5\/04) - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-58.png","datePublished":"2020-08-30T20:09:14+00:00","dateModified":"2020-08-30T20:58:19+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"How to set up RS232 to DH+ Passthru on a 5\/04 processor. We'll walk through the channel config, Status File setup, and the RSLinx Driver.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-58.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/08\/image-58.png","width":783,"height":471},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/08\/30\/rs232-to-dh-passthru\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"RS232 to DH+ Passthru"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2988","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=2988"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/2988\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/2989"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=2988"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=2988"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=2988"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}