{"id":299,"date":"2017-04-15T20:57:44","date_gmt":"2017-04-15T20:57:44","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=299"},"modified":"2017-05-17T14:50:30","modified_gmt":"2017-05-17T14:50:30","slug":"siemens-iot2020-configuration","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/","title":{"rendered":"Siemens Simatic IOT2020 Configuration"},"content":{"rendered":"<h2>Introduction to IOT2020<\/h2>\n<p>In this document, we will setup and configure the Siemens Simatic IOT2020 processor to be able to accept a simple &#8220;Blink&#8221; program using the Arduino IDE. \u00a0 Although I believe the information in this document to be accurate, you assume all responsibilities for safety, and must verify the information before utilizing it in any way. \u00a0Please let me know if you find any errors in this procedure.<\/p><div id=\"bryce-3018426363\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n<p>The Siemens IOT2020 is a gateway device that allows you to program I\/O as you would an Uno board. \u00a0 It also has a Linux based operating system, which gives more capability than a standard Atmega 328 processor. \u00a0 The setup is very simple. \u00a0 One of the problems I had when I first set up the board was that I was attempting to use the FTDI programmer to upload the sketch. \u00a0 The FTDI programmer works great for interfacing with the Linux operating system (via serial console), but I was only successful uploading the sketch through the Micro-USB interface once the operating system was installed.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-300 size-large lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7070-e1492286676663-1024x768.jpg\" alt=\"IOT2020\" width=\"640\" height=\"480\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7070-e1492286676663-1024x768.jpg 1024w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7070-e1492286676663-300x225.jpg 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7070-e1492286676663-768x576.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7070-e1492286676663.jpg 1000w\" data-sizes=\"(max-width: 640px) 100vw, 640px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 640px; --smush-placeholder-aspect-ratio: 640\/480;\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2>Hardware<\/h2>\n<p>The IOT2020 has several status indicators: \u00a0Power, SD Active, USB Power, Over Current, and a User light (similar to LED #13 on a<img decoding=\"async\" class=\"alignright size-medium wp-image-301 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7073-300x225.jpg\" alt=\"IOT2020 Power\" width=\"300\" height=\"225\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7073-300x225.jpg 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7073-768x576.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7073-1024x768.jpg 1024w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7073.jpg 1000w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/225;\" \/>n Uno board) \u00a0This module can be powered by 9 to 36 VDC according to the user manual. \u00a0 In my case, I&#8217;ve powered the module from a computer power supply unit using the 12V leads that would normally connect to the hard drive. \u00a0You also have a RESET button, and a User button.<\/p>\n<p>Here, I&#8217;ve already connected the power supply, but we will apply power later, after the SD card has been set up and a few connections have been made.<\/p>\n<p>&nbsp;<\/p>\n<h2>MicroSD Image<\/h2>\n<p>I used a 32 GB Sandisk Ultra Plus for this configuration, and downloaded the SD image from this address:<\/p>\n<p><a href=\"http:\/\/downloads.arduino.cc\/iot2000\/iot2000-example-image-iot2000-20170130142104.rootfs.img\">http:\/\/downloads.arduino.cc\/iot2000\/iot2000-example-image-iot2000-20170130142104.rootfs.img<\/a><\/p>\n<p>The image is also available from Siemens website, and I would encourage you to search for the latest example image.<\/p>\n<p>Once the image is downloaded, you will burn the image to your MicroSD card. \u00a0 You can use Win32 disk imager at this address:<\/p>\n<p><a href=\"https:\/\/sourceforge.net\/projects\/win32diskimager\/\">https:\/\/sourceforge.net\/projects\/win32diskimager\/<\/a><\/p>\n<p>Or another option is to use Etcher:<\/p>\n<p><a href=\"https:\/\/etcher.io\/\">https:\/\/etcher.io\/<\/a><\/p>\n<p>Once the MicroSD card has been set up, you can place it into your IOT2020. \u00a0 To open the door for the MicroSD slot, gently push the bracket toward the bottom of the module, then the bracket will swing upward. \u00a0 \u00a0You can then place the MicroSD card into it&#8217;s holder, and re-position the bracket, and slide the bracket toward the top of the module to lock the MicroSD card into place.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-302 size-large lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7071-e1492287791835-1024x768.jpg\" alt=\"Inside IOT2020\" width=\"640\" height=\"480\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7071-e1492287791835-1024x768.jpg 1024w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7071-e1492287791835-300x225.jpg 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7071-e1492287791835-768x576.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7071-e1492287791835.jpg 1000w\" data-sizes=\"(max-width: 640px) 100vw, 640px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 640px; --smush-placeholder-aspect-ratio: 640\/480;\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2>Startup<\/h2>\n<p>This next step is not necessary if you are just going to use the Arduino IDE, but it&#8217;s nice to have an FTDI programmer to see what is going on as the processor boots up. \u00a0 In my case, I have an FTDI programmer that I&#8217;ve set up for 3.3v. \u00a0I&#8217;ve then connected GND to the right pin of the programming header&#8230; \u00a0 TX to RX, and RX to TX as shown. \u00a0I didn&#8217;t plug the FTDI programmer directly into the board, because my cable is heavy, and I didn&#8217;t want to put much stress on the IOT2020&#8217;s board.<\/p>\n<p><img decoding=\"async\" class=\"wp-image-303 size-large aligncenter lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7078-e1492288033140-768x1024.jpg\" alt=\"FTDI Basic Programmer\" width=\"640\" height=\"853\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7078-e1492288033140-768x1024.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7078-e1492288033140-225x300.jpg 225w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7078-e1492288033140.jpg 750w\" data-sizes=\"(max-width: 640px) 100vw, 640px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 640px; --smush-placeholder-aspect-ratio: 640\/853;\" \/><\/p>\n<p>As long as the drivers are installed (and you have a good cable!!), You should be able to see the COM port of your FTDI programmer under Tools | Port in the Arduino IDE.<\/p>\n<p>Next, I opened the Serial Monitor, and applied power to the IOT2020, and was able to watch the bootup process. \u00a0 Since the default IP address is 192.168,200.1, I need to change this. \u00a0 I closed the Serial Monitor, and connected with PUTTY (through the same COM port). \u00a0 I&#8217;m using Debian 8, so my com port was \/dev\/ttyUSB0. \u00a0 The login is &#8220;root&#8221; with no password.<img decoding=\"async\" class=\"size-medium wp-image-305 alignleft lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/interfaces-300x210.png\" alt=\"interfaces\" width=\"300\" height=\"210\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/interfaces-300x210.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/interfaces.png 495w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/210;\" \/><\/p>\n<p>Then, I typed \u00a0 \u00a0vi \/etc\/network\/interfaces \u00a0 to change the IP as shown:<\/p>\n<p>Then press the escape key, then :wq \u00a0 (colon w q) to write the file and quit the editor. \u00a0You can then type &#8220;reboot&#8221; to reboot the IOT2020 if you wish to use SSH in the future over your network.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<h2>Programming<\/h2>\n<p>Next, I co<img decoding=\"async\" class=\"alignright size-medium wp-image-306 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7077-300x225.jpg\" alt=\"IOT2020 USB\" width=\"300\" height=\"225\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7077-300x225.jpg 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7077-768x576.jpg 768w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7077-1024x768.jpg 1024w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7077.jpg 1000w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/225;\" \/>nnected my MicroUSB cable to the IOT2020. \u00a0In Windows, you may need to install a driver for this module. Check &#8220;Device Manager&#8221; in the windows control panel to ensure your\u00a0IOT2020 was recognized properly. \u00a0 Again, I&#8217;m using Debian 8, so I didn&#8217;t have a problem at all.<\/p>\n<p>Make note of the COM port the IOT2020 appears on. \u00a0 We will need this later when we download the &#8220;Blink&#8221; Sketch. \u00a0If your IOT2020 does not appear on your PC, please be sure you are using a good quality data cable as some cables can only be used for charging a device such as a phone.<\/p>\n<p>In the Arduino IDE, we must add support for the Intel (R) Galileo Gen 2. \u00a0 Under Tools | Boards, go to your boards manager and search for, and install Intel (R) i586 support.<\/p>\n<p>Under Tools | Boards, select the Intel (R) Galileo Gen 2. \u00a0 Under Tools | Port, select the COM port for your IOT2020.<\/p>\n<p>Upload your sketch to the IOT2020, and you should see the USER indicator begin to blink.<\/p>\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-3527544103\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to IOT2020 In this document, we will setup and configure the Siemens Simatic IOT2020 processor to be able to accept a simple &#8220;Blink&#8221; program using the Arduino IDE. \u00a0 Although I believe the information in this document to be accurate, you assume all responsibilities for safety, and must verify the information before utilizing it <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":302,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[10,5],"tags":[],"class_list":{"0":"post-299","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-advanced","8":"category-arduino-other-microprocessors","9":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Setup and Configuration of the Siemens Simatic IOT2020<\/title>\n<meta name=\"description\" content=\"In this document, we will setup and configure the Siemens IOT2020 Gateway to accept an Arduino Sketch, and configure it&#039;s IP Address.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Setup and Configuration of the Siemens Simatic IOT2020\" \/>\n<meta property=\"og:description\" content=\"In this document, we will setup and configure the Siemens IOT2020 Gateway to accept an Arduino Sketch, and configure it&#039;s IP Address.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2017-04-15T20:57:44+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-05-17T14:50:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7071-e1492287791835.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"750\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"Siemens Simatic IOT2020 Configuration\",\"datePublished\":\"2017-04-15T20:57:44+00:00\",\"dateModified\":\"2017-05-17T14:50:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/\"},\"wordCount\":871,\"commentCount\":2,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/04\\\/IMG_7071-e1492287791835.jpg\",\"articleSection\":[\"Advanced\",\"Arduino and other microprocessors\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/\",\"name\":\"Setup and Configuration of the Siemens Simatic IOT2020\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/04\\\/IMG_7071-e1492287791835.jpg\",\"datePublished\":\"2017-04-15T20:57:44+00:00\",\"dateModified\":\"2017-05-17T14:50:30+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"In this document, we will setup and configure the Siemens IOT2020 Gateway to accept an Arduino Sketch, and configure it's IP Address.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/04\\\/IMG_7071-e1492287791835.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/04\\\/IMG_7071-e1492287791835.jpg\",\"width\":1000,\"height\":750,\"caption\":\"Inside IOT2020\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/04\\\/15\\\/siemens-iot2020-configuration\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Siemens Simatic IOT2020 Configuration\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Setup and Configuration of the Siemens Simatic IOT2020","description":"In this document, we will setup and configure the Siemens IOT2020 Gateway to accept an Arduino Sketch, and configure it's IP Address.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/","og_locale":"en_US","og_type":"article","og_title":"Setup and Configuration of the Siemens Simatic IOT2020","og_description":"In this document, we will setup and configure the Siemens IOT2020 Gateway to accept an Arduino Sketch, and configure it's IP Address.","og_url":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2017-04-15T20:57:44+00:00","article_modified_time":"2017-05-17T14:50:30+00:00","og_image":[{"width":1000,"height":750,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7071-e1492287791835.jpg","type":"image\/jpeg"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"Siemens Simatic IOT2020 Configuration","datePublished":"2017-04-15T20:57:44+00:00","dateModified":"2017-05-17T14:50:30+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/"},"wordCount":871,"commentCount":2,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7071-e1492287791835.jpg","articleSection":["Advanced","Arduino and other microprocessors"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/","url":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/","name":"Setup and Configuration of the Siemens Simatic IOT2020","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7071-e1492287791835.jpg","datePublished":"2017-04-15T20:57:44+00:00","dateModified":"2017-05-17T14:50:30+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"In this document, we will setup and configure the Siemens IOT2020 Gateway to accept an Arduino Sketch, and configure it's IP Address.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7071-e1492287791835.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/04\/IMG_7071-e1492287791835.jpg","width":1000,"height":750,"caption":"Inside IOT2020"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/04\/15\/siemens-iot2020-configuration\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"Siemens Simatic IOT2020 Configuration"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/299","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=299"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/299\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/302"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=299"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=299"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=299"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}