{"id":3111,"date":"2020-09-07T12:01:20","date_gmt":"2020-09-07T12:01:20","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=3111"},"modified":"2020-09-07T13:17:14","modified_gmt":"2020-09-07T13:17:14","slug":"factorytalk-view-se-trends-and-data-log","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/","title":{"rendered":"FactoryTalk View SE Trends and Data Log"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Introduction to FactoryTalk View SE Trends and Data Log<\/h3>\n\n\n\n<p>With FactoryTalk View SE Trends and Data Log, we will log background data, and plot that data onto a trend chart.   Without the data log, the trend chart will only show live data at the time the trend was started.<\/p><div id=\"bryce-2187473323\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<p>Basically, we&#8217;ll walk through how to create a data log.  We&#8217;ll run the data log in a startup macro, and associate the data log to a trend chart.  Altogether, we&#8217;ll have a trend chart where the operator can view data from any point in time.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Create the Data Log<\/h4>\n\n\n\n<p>At first, we&#8217;ll right click the data log models, and add a new data log.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"523\" height=\"137\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-48.png\" alt=\"\" class=\"wp-image-3112 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-48.png 523w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-48-300x79.png 300w\" data-sizes=\"(max-width: 523px) 100vw, 523px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 523px; --smush-placeholder-aspect-ratio: 523\/137;\" \/><\/figure>\n\n\n\n<p>In the general tab, we will obviously put in a description of our chart.   For example, we&#8217;ll just log to a file set.   Conversely, you could log to an SQL Server using an ODBC connection.<\/p>\n\n\n\n<p>At this time, let&#8217;s leave the paths at their default location.  Go to the &#8220;File Management&#8221; tab.  In this case, we will leave the settings at default, but you could choose when you would like to start a new log file on your storage device.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"634\" height=\"521\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-49.png\" alt=\"\" class=\"wp-image-3113 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-49.png 634w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-49-300x247.png 300w\" data-sizes=\"(max-width: 634px) 100vw, 634px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 634px; --smush-placeholder-aspect-ratio: 634\/521;\" \/><\/figure>\n\n\n\n<p>Go to Log Triggers, and define how often you need to sample the tag.   We&#8217;ll set this at 1 second.  Remember this is just the sample rate.   This is not the amount of time from left to right across the trend chart.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"642\" height=\"230\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-50.png\" alt=\"\" class=\"wp-image-3114 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-50.png 642w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-50-300x107.png 300w\" data-sizes=\"(max-width: 642px) 100vw, 642px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 642px; --smush-placeholder-aspect-ratio: 642\/230;\" \/><\/figure>\n\n\n\n<p>It&#8217;s most important to go to &#8220;Tags In Model&#8221;, and add the tags  you wish to log.   Be sure to hit the &#8220;Add&#8221; button after selecting  your tag, so the tags appear under &#8220;Tags in Model&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"632\" height=\"428\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-51.png\" alt=\"\" class=\"wp-image-3115 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-51.png 632w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-51-300x203.png 300w\" data-sizes=\"(max-width: 632px) 100vw, 632px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 632px; --smush-placeholder-aspect-ratio: 632\/428;\" \/><\/figure>\n\n\n\n<p>Press OK, and save the changes.  In this example, I&#8217;ll name it &#8220;MyDataLog&#8221;.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Create a Startup Macro <\/h3>\n\n\n\n<p>We need the data log model to run at startup.   A startup macro allows us to do this, and many other commands we might wish to run at startup.  If you are modifying an existing project, just add the command &#8220;DataLogOn MyDataLog&#8221;.   Where MyDataLog is the name of the data log you just created.  In this case, though, we&#8217;ll create a new startup macro.  Right-Click Macros, and add a new macro.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"412\" height=\"174\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-52.png\" alt=\"\" class=\"wp-image-3117 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-52.png 412w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-52-300x127.png 300w\" data-sizes=\"(max-width: 412px) 100vw, 412px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 412px; --smush-placeholder-aspect-ratio: 412\/174;\" \/><\/figure>\n\n\n\n<p>Add the command as shown below.   Close your macro, and save it as &#8220;Startup&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"663\" height=\"174\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-53.png\" alt=\"\" class=\"wp-image-3119 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-53.png 663w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-53-300x79.png 300w\" data-sizes=\"(max-width: 663px) 100vw, 663px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 663px; --smush-placeholder-aspect-ratio: 663\/174;\" \/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">Create the FactoryTalk View SE Trends<\/h3>\n\n\n\n<p>At last, we&#8217;ll add the trend chart.   On a new display, go to Objects | Trending | Trend.   Add the object as large as possible onto this display.   Be sure you have navigation buttons to get to and from this display.<\/p>\n\n\n\n<p>In the properties of the Trend chart, go to Pens.   Select Data Log Model as the pen source.  Add Pens.  Choose the tags you wish to monitor, then press OK.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"756\" height=\"582\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-54.png\" alt=\"\" class=\"wp-image-3121 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-54.png 756w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-54-300x231.png 300w\" data-sizes=\"(max-width: 756px) 100vw, 756px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 756px; --smush-placeholder-aspect-ratio: 756\/582;\" \/><\/figure>\n\n\n\n<p>Next, be sure to set the Min and Max values of the tag.  You can also adjust the color and width of the pen.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"782\" height=\"169\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-55.png\" alt=\"\" class=\"wp-image-3122 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-55.png 782w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-55-300x65.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-55-768x166.png 768w\" data-sizes=\"(max-width: 782px) 100vw, 782px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 782px; --smush-placeholder-aspect-ratio: 782\/169;\" \/><\/figure>\n\n\n\n<p>Go to the X-Axis, and set your time span.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"415\" height=\"284\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-56.png\" alt=\"\" class=\"wp-image-3123 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-56.png 415w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-56-300x205.png 300w\" data-sizes=\"(max-width: 415px) 100vw, 415px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 415px; --smush-placeholder-aspect-ratio: 415\/284;\" \/><\/figure>\n\n\n\n<p>Finally, on the Y-Axis, we&#8217;ll choose &#8220;Preset&#8221;.   This will use the min and max settings from the pens tab.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"774\" height=\"384\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-57.png\" alt=\"\" class=\"wp-image-3124 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-57.png 774w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-57-300x149.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-57-768x381.png 768w\" data-sizes=\"(max-width: 774px) 100vw, 774px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 774px; --smush-placeholder-aspect-ratio: 774\/384;\" \/><\/figure>\n\n\n\n<p>Close your display.  In this case, I&#8217;ll save it as &#8220;Trends&#8221;, and just make that the startup screen.  Again, if the trends display is not your startup screen, be sure  you have navigation buttons to get to and from this display screen.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Launch the Client<\/h3>\n\n\n\n<p>Even though we have a button to test the single display in FactoryTalk View, that will not work for this example.   We need to run the full application, because we are testing the datalog as well.   In order for the startup macro to run, we need to create a client file.  <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"434\" height=\"124\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-58.png\" alt=\"\" class=\"wp-image-3126 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-58.png 434w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-58-300x86.png 300w\" data-sizes=\"(max-width: 434px) 100vw, 434px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 434px; --smush-placeholder-aspect-ratio: 434\/124;\" \/><\/figure>\n\n\n\n<p>Click the &#8220;+&#8221; to create a FactoryTalk View SE Client configuration file.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"789\" height=\"524\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-59.png\" alt=\"\" class=\"wp-image-3128 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-59.png 789w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-59-300x199.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-59-768x510.png 768w\" data-sizes=\"(max-width: 789px) 100vw, 789px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 789px; --smush-placeholder-aspect-ratio: 789\/524;\" \/><\/figure>\n\n\n\n<p>We&#8217;ll just continue with the default settings.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"914\" height=\"202\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-60.png\" alt=\"\" class=\"wp-image-3129 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-60.png 914w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-60-300x66.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-60-768x170.png 768w\" data-sizes=\"(max-width: 914px) 100vw, 914px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 914px; --smush-placeholder-aspect-ratio: 914\/202;\" \/><\/figure>\n\n\n\n<p>Be sure to choose the application type, the application name, initial display, and startup macro.  Then click  &#8220;Save&#8221; and &#8220;Run&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"905\" height=\"567\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-61.png\" alt=\"\" class=\"wp-image-3130 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-61.png 905w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-61-300x188.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-61-768x481.png 768w\" data-sizes=\"(max-width: 905px) 100vw, 905px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 905px; --smush-placeholder-aspect-ratio: 905\/567;\" \/><\/figure>\n\n\n\n<p>Your trend chart should now be all set up and running!<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"977\" height=\"544\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-62.png\" alt=\"\" class=\"wp-image-3131 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-62.png 977w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-62-300x167.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-62-768x428.png 768w\" data-sizes=\"(max-width: 977px) 100vw, 977px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 977px; --smush-placeholder-aspect-ratio: 977\/544;\" \/><\/figure>\n\n\n\n<p>For more information, visit the<a href=\"https:\/\/bryceautomation.com\/index.php\/category\/factorytalk-view-se\/\"> FactoryTalk View SE Category Page!<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-155119055\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to FactoryTalk View SE Trends and Data Log With FactoryTalk View SE Trends and Data Log, we will log background data, and plot that data onto a trend chart. Without the data log, the trend chart will only show live data at the time the trend was started. Basically, we&#8217;ll walk through how to <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":3131,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[205,195],"tags":[241,197,46,248],"class_list":{"0":"post-3111","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-factorytalk-view-se","8":"category-plantpax","9":"tag-data-log","10":"tag-factorytalk-view-se","11":"tag-trending","12":"tag-trends","13":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>FactoryTalk View SE Trends and Data Log - Bryce Automation<\/title>\n<meta name=\"description\" content=\"How to create FactoryTalk View SE Trends, associate a data log model. We will run the datalog model at startup, and launch the SE client.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FactoryTalk View SE Trends and Data Log - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"How to create FactoryTalk View SE Trends, associate a data log model. We will run the datalog model at startup, and launch the SE client.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-09-07T12:01:20+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-09-07T13:17:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-62.png\" \/>\n\t<meta property=\"og:image:width\" content=\"977\" \/>\n\t<meta property=\"og:image:height\" content=\"544\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"FactoryTalk View SE Trends and Data Log\",\"datePublished\":\"2020-09-07T12:01:20+00:00\",\"dateModified\":\"2020-09-07T13:17:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/\"},\"wordCount\":678,\"commentCount\":2,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/image-62.png\",\"keywords\":[\"data log\",\"FactoryTalk View SE\",\"Trending\",\"trends\"],\"articleSection\":[\"FactoryTalk View SE\",\"PlantPAx\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/\",\"name\":\"FactoryTalk View SE Trends and Data Log - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/image-62.png\",\"datePublished\":\"2020-09-07T12:01:20+00:00\",\"dateModified\":\"2020-09-07T13:17:14+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"How to create FactoryTalk View SE Trends, associate a data log model. We will run the datalog model at startup, and launch the SE client.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/image-62.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/09\\\/image-62.png\",\"width\":977,\"height\":544,\"caption\":\"Trend Chart\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/09\\\/07\\\/factorytalk-view-se-trends-and-data-log\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FactoryTalk View SE Trends and Data Log\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FactoryTalk View SE Trends and Data Log - Bryce Automation","description":"How to create FactoryTalk View SE Trends, associate a data log model. We will run the datalog model at startup, and launch the SE client.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/","og_locale":"en_US","og_type":"article","og_title":"FactoryTalk View SE Trends and Data Log - Bryce Automation","og_description":"How to create FactoryTalk View SE Trends, associate a data log model. We will run the datalog model at startup, and launch the SE client.","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-09-07T12:01:20+00:00","article_modified_time":"2020-09-07T13:17:14+00:00","og_image":[{"width":977,"height":544,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-62.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"FactoryTalk View SE Trends and Data Log","datePublished":"2020-09-07T12:01:20+00:00","dateModified":"2020-09-07T13:17:14+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/"},"wordCount":678,"commentCount":2,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-62.png","keywords":["data log","FactoryTalk View SE","Trending","trends"],"articleSection":["FactoryTalk View SE","PlantPAx"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/","name":"FactoryTalk View SE Trends and Data Log - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-62.png","datePublished":"2020-09-07T12:01:20+00:00","dateModified":"2020-09-07T13:17:14+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"How to create FactoryTalk View SE Trends, associate a data log model. We will run the datalog model at startup, and launch the SE client.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-62.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/09\/image-62.png","width":977,"height":544,"caption":"Trend Chart"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/09\/07\/factorytalk-view-se-trends-and-data-log\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"FactoryTalk View SE Trends and Data Log"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/3111","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=3111"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/3111\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/3131"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=3111"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=3111"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=3111"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}