{"id":3710,"date":"2020-12-02T19:13:24","date_gmt":"2020-12-02T19:13:24","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=3710"},"modified":"2021-08-25T23:25:09","modified_gmt":"2021-08-25T23:25:09","slug":"connection-not-scheduled","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/","title":{"rendered":"Connection Not Scheduled"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">Resolving Connection Not Scheduled error<\/h4>\n\n\n\n<p>Anyone who has done work with Controlnet has gotten the &#8220;Connection Not Scheduled&#8221; error.   Although this is easy to resolve, there are a few steps to schedule the connection.   As long as you have RSNetworx for Controlnet software, we should be able to fix this issue.<\/p><div id=\"bryce-2545489332\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<p>Controlnet works a little bit differently than Ethernet.   After changing a scheduled device, we must run RSNetworx for Controlnet to re-schedule the network.  Modern Controlnet networks have multiple &#8220;Keepers&#8221;.   The keeper is in charge of the network.  The lowest node number on the network that is a keeper capable device (and a valid keeper) is the active keeper.  If this node goes down for some reason, the next node on the network that is a valid keeper becomes the active keeper.<\/p>\n\n\n\n<p>Let&#8217;s take a look at our situation.   As can be seen, we have caution signs on a few devices.  If we look at the first device that we lost, we see the error &#8220;Connection Not Scheduled&#8221;.  <\/p>\n\n\n\n<p><strong><em>Warning:  By using this procedure, each process on the ControlNet link will need to go to &#8220;Program&#8221; mode.   This means your system will likely go down!<\/em><\/strong>  Be sure you take all safety precautions, back up any necessary files, and disable prime movers (remove any possibility of harm or damage) prior to testing.  Be sure you know what you are doing!<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"421\" height=\"143\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-14.png\" alt=\"\" class=\"wp-image-3712 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-14.png 421w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-14-300x102.png 300w\" data-sizes=\"(max-width: 421px) 100vw, 421px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 421px; --smush-placeholder-aspect-ratio: 421\/143;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">RSNetworx for Controlnet<\/h4>\n\n\n\n<p>At this point, I&#8217;ll open RSNetworx for Controlnet.  In this case, I will only have 3 steps to follow to schedule the network.   First, I&#8217;ll go online with the network.  Next, I&#8217;ll enable edits on the network.  Lastly, I&#8217;ll save and re-write connetions to the network.  After that, our error should go away.   I&#8217;m going to schedule the network from scratch.  I have no previous Controlnet file to open and download to the network.  I use the following procedure to automatically find connection requests and to reschedule the network.  This should work as long as no manual scheduling is required (such as in the PLC-5).<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Step 1) Go Online with the Controlnet<\/h4>\n\n\n\n<p>In RSNetworx, click &#8220;Network | Online&#8221;.   Browse for the ControlNet network.  Be sure it&#8217;s the word &#8220;Controlnet&#8221; that you have highlighted in the RSWho screen, then press &#8220;OK&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"352\" height=\"387\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-15.png\" alt=\"\" class=\"wp-image-3713 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-15.png 352w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-15-273x300.png 273w\" data-sizes=\"(max-width: 352px) 100vw, 352px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 352px; --smush-placeholder-aspect-ratio: 352\/387;\" \/><\/figure>\n\n\n\n<p>At this point, RSNetworx for Controlnet will browse all of the nodes on the Controlnet Link.  Each link might have up to 99 nodes.  Let the browser finish, and it will populate the chassis as shown.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"566\" height=\"173\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-16.png\" alt=\"\" class=\"wp-image-3714 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-16.png 566w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-16-300x92.png 300w\" data-sizes=\"(max-width: 566px) 100vw, 566px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 566px; --smush-placeholder-aspect-ratio: 566\/173;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Step 2)  Enable Edits<\/h4>\n\n\n\n<p>In this step, we will simply enable edits on the network, and download the information.  I&#8217;ll check the box for &#8220;Edits Enabled&#8221; as shown.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"564\" height=\"174\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-17.png\" alt=\"\" class=\"wp-image-3715 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-17.png 564w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-17-300x93.png 300w\" data-sizes=\"(max-width: 564px) 100vw, 564px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 564px; --smush-placeholder-aspect-ratio: 564\/174;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Step 3)  Save and re-write connections<\/h4>\n\n\n\n<p>In RSLogix (Studio) 5000, there are still errors on the modules.   After this step, the errors should clear.  After that the I\/O should be working.  Click &#8220;File | Save&#8221;, or the &#8220;Save&#8221; icon in the standard toolbar.   You will see a prompt for a file name and to optimize and re-write connections.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"381\" height=\"136\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-18.png\" alt=\"\" class=\"wp-image-3716 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-18.png 381w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-18-300x107.png 300w\" data-sizes=\"(max-width: 381px) 100vw, 381px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 381px; --smush-placeholder-aspect-ratio: 381\/136;\" \/><\/figure>\n\n\n\n<p>Finally, verify the error &#8220;Connection Not Scheduled&#8221; is gone.  As you can see, we no longer have any faults, and the I\/O is now working.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"280\" height=\"153\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-19.png\" alt=\"\" class=\"wp-image-3718 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 280px; --smush-placeholder-aspect-ratio: 280\/153;\" \/><\/figure>\n\n\n\n<p>For more information on ControlLogix, visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/controllogix\/\">ControlLogix Category Page!<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-1016234977\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Resolving Connection Not Scheduled error Anyone who has done work with Controlnet has gotten the &#8220;Connection Not Scheduled&#8221; error. Although this is easy to resolve, there are a few steps to schedule the connection. As long as you have RSNetworx for Controlnet software, we should be able to fix this issue. Controlnet works a little <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":3720,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[269,267,268],"class_list":{"0":"post-3710","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-controllogix","8":"tag-connection-not-scheduled","9":"tag-controlnet","10":"tag-rsnetworx","11":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Connection Not Scheduled - How to Resolve - Bryce Automation<\/title>\n<meta name=\"description\" content=\"How to resolve &quot;Connection Not Scheduled&quot; error for a Controlnet network on a ControLogix system using RSNetworx for Controlnet\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Connection Not Scheduled - How to Resolve - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"How to resolve &quot;Connection Not Scheduled&quot; error for a Controlnet network on a ControLogix system using RSNetworx for Controlnet\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-12-02T19:13:24+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2021-08-25T23:25:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/Screenshot-from-2020-12-02-13-12-26.png\" \/>\n\t<meta property=\"og:image:width\" content=\"557\" \/>\n\t<meta property=\"og:image:height\" content=\"394\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"Connection Not Scheduled\",\"datePublished\":\"2020-12-02T19:13:24+00:00\",\"dateModified\":\"2021-08-25T23:25:09+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/\"},\"wordCount\":536,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/Screenshot-from-2020-12-02-13-12-26.png\",\"keywords\":[\"connection not scheduled\",\"Controlnet\",\"RSnetworx\"],\"articleSection\":[\"ControlLogix\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/\",\"name\":\"Connection Not Scheduled - How to Resolve - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/Screenshot-from-2020-12-02-13-12-26.png\",\"datePublished\":\"2020-12-02T19:13:24+00:00\",\"dateModified\":\"2021-08-25T23:25:09+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"How to resolve \\\"Connection Not Scheduled\\\" error for a Controlnet network on a ControLogix system using RSNetworx for Controlnet\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/Screenshot-from-2020-12-02-13-12-26.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/Screenshot-from-2020-12-02-13-12-26.png\",\"width\":557,\"height\":394},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/02\\\/connection-not-scheduled\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Connection Not Scheduled\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Connection Not Scheduled - How to Resolve - Bryce Automation","description":"How to resolve \"Connection Not Scheduled\" error for a Controlnet network on a ControLogix system using RSNetworx for Controlnet","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/","og_locale":"en_US","og_type":"article","og_title":"Connection Not Scheduled - How to Resolve - Bryce Automation","og_description":"How to resolve \"Connection Not Scheduled\" error for a Controlnet network on a ControLogix system using RSNetworx for Controlnet","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-12-02T19:13:24+00:00","article_modified_time":"2021-08-25T23:25:09+00:00","og_image":[{"width":557,"height":394,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/Screenshot-from-2020-12-02-13-12-26.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"Connection Not Scheduled","datePublished":"2020-12-02T19:13:24+00:00","dateModified":"2021-08-25T23:25:09+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/"},"wordCount":536,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/Screenshot-from-2020-12-02-13-12-26.png","keywords":["connection not scheduled","Controlnet","RSnetworx"],"articleSection":["ControlLogix"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/","name":"Connection Not Scheduled - How to Resolve - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/Screenshot-from-2020-12-02-13-12-26.png","datePublished":"2020-12-02T19:13:24+00:00","dateModified":"2021-08-25T23:25:09+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"How to resolve \"Connection Not Scheduled\" error for a Controlnet network on a ControLogix system using RSNetworx for Controlnet","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/Screenshot-from-2020-12-02-13-12-26.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/Screenshot-from-2020-12-02-13-12-26.png","width":557,"height":394},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/02\/connection-not-scheduled\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"Connection Not Scheduled"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/3710","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=3710"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/3710\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/3720"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=3710"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=3710"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=3710"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}