{"id":5050,"date":"2020-12-13T21:08:58","date_gmt":"2020-12-13T21:08:58","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=5050"},"modified":"2020-12-14T11:17:13","modified_gmt":"2020-12-14T11:17:13","slug":"factorytalk-view-gauge","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/","title":{"rendered":"FactoryTalk View Gauge"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">Introduction to the FactoryTalk View Gauge Object<\/h4>\n\n\n\n<p>Generally, we&#8217;ll use a FactoryTalk View Gauge Object to graphically display an analog signal.   In this example, we&#8217;ll display a bearing temperature.   Additionally, we will set thresholds on the gauge object.  This allows the gauge to change colors when certain thresholds are met.  For example, let&#8217;s look at a bearing temperature.  Normally, we&#8217;ll want the bearing temperature to be between 100 and 180 Fahrenheight.  Therefore, we&#8217;ll display this range as green.   Lower than this, the gauge will display yellow.  Likewise, if the bearing goes above this range, we will display the gauge in red.<\/p><div id=\"bryce-3818098924\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h4 class=\"wp-block-heading\">Add the FactoryTalk View Gauge Object to your display<\/h4>\n\n\n\n<p>Before we start, lets add the gauge object to your display.   You will find this under Objects | Gauge and Graph | Gauge.  Because the lowest range on our scale is yellow, we&#8217;ll set this as our initial fill color.  Be sure to change the sweep style to either &#8220;Solid Fill&#8221; or &#8220;Gradient fill&#8221;.   If you choose &#8220;Point&#8221;, you will not see the threshold colors.   Also remember that &#8220;Gradient Fill&#8221; might not be supported by some Panelviews, or older versions for FactoryTalk View ME.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"440\" height=\"337\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-49.png\" alt=\"\" class=\"wp-image-5052 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-49.png 440w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-49-300x230.png 300w\" data-sizes=\"(max-width: 440px) 100vw, 440px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 440px; --smush-placeholder-aspect-ratio: 440\/337;\" \/><\/figure>\n\n\n\n<p>Next, go to the &#8220;Display&#8221; tab.  Because 150 degrees is our nominal temperature, set the scale from 0 to 300 degrees.  Be sure to choose two thresholds.  The first threshold will turn green at 100 degrees.  Likewise, the second threshold will turn red at 180 degrees.  Remember to set the colors for each threshold as well.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"444\" height=\"431\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-50.png\" alt=\"\" class=\"wp-image-5053 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-50.png 444w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-50-300x291.png 300w\" data-sizes=\"(max-width: 444px) 100vw, 444px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 444px; --smush-placeholder-aspect-ratio: 444\/431;\" \/><\/figure>\n\n\n\n<p>Finally, go to the &#8220;Connections&#8221; Tab.  Browse for the bearing temperature in your processor.  Press &#8220;Apply&#8221; and &#8220;OK&#8221;.  Don&#8217;t forget to refresh all folders if you are not seeing your tag in the tag browser.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"444\" height=\"106\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-51.png\" alt=\"\" class=\"wp-image-5054 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-51.png 444w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-51-300x72.png 300w\" data-sizes=\"(max-width: 444px) 100vw, 444px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 444px; --smush-placeholder-aspect-ratio: 444\/106;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Test the FactoryTalk View Gauge Object<\/h4>\n\n\n\n<p>Of course, now we need to test the project to make sure it&#8217;s working as we expect.  Since we don&#8217;t need any background services to run, we&#8217;ll just test this display.  In this case, there is no need to do a full test run.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"253\" height=\"147\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-52.png\" alt=\"\" class=\"wp-image-5055 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 253px; --smush-placeholder-aspect-ratio: 253\/147;\" \/><\/figure>\n\n\n\n<p>Obviously, if you are below 100 degrees, the graph will display a yellow background.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"235\" height=\"199\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-53.png\" alt=\"\" class=\"wp-image-5056 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 235px; --smush-placeholder-aspect-ratio: 235\/199;\" \/><\/figure>\n\n\n\n<p>At nominal temperature, we are in the green!<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"248\" height=\"195\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-54.png\" alt=\"\" class=\"wp-image-5057 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 248px; --smush-placeholder-aspect-ratio: 248\/195;\" \/><\/figure>\n\n\n\n<p>Finally, if our bearing is running too hot, we are in the red.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"245\" height=\"203\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-55.png\" alt=\"\" class=\"wp-image-5058 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 245px; --smush-placeholder-aspect-ratio: 245\/203;\" \/><\/figure>\n\n\n\n<p>Don&#8217;t forget to explore some of the other objects available for Analog signals such as the <a href=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/factorytalk-view-bar-graph\/\">bar graph<\/a>, <a href=\"https:\/\/bryceautomation.com\/index.php\/2017\/09\/14\/factorytalk-view-numeric-display\/\">numeric display<\/a>, and <a href=\"https:\/\/bryceautomation.com\/index.php\/2020\/09\/01\/data-log-in-factorytalk-view-me\/\">Trending with the data log model!<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-4104113161\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to the FactoryTalk View Gauge Object Generally, we&#8217;ll use a FactoryTalk View Gauge Object to graphically display an analog signal. In this example, we&#8217;ll display a bearing temperature. Additionally, we will set thresholds on the gauge object. This allows the gauge to change colors when certain thresholds are met. For example, let&#8217;s look at <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":5058,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[50],"tags":[28,276],"class_list":{"0":"post-5050","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-factorytalk-view-me","8":"tag-analog","9":"tag-gauge","10":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>FactoryTalk View Gauge Object - Bryce Automation<\/title>\n<meta name=\"description\" content=\"We&#039;ll set up a FactoryTalk View Gauge Object to monitor a bearing temperature. We&#039;ll also set up Thresholds and define acceptable ranges.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FactoryTalk View Gauge Object - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"We&#039;ll set up a FactoryTalk View Gauge Object to monitor a bearing temperature. We&#039;ll also set up Thresholds and define acceptable ranges.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-12-13T21:08:58+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-12-14T11:17:13+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-55.png\" \/>\n\t<meta property=\"og:image:width\" content=\"245\" \/>\n\t<meta property=\"og:image:height\" content=\"203\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"FactoryTalk View Gauge\",\"datePublished\":\"2020-12-13T21:08:58+00:00\",\"dateModified\":\"2020-12-14T11:17:13+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/\"},\"wordCount\":404,\"commentCount\":1,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/image-55.png\",\"keywords\":[\"Analog\",\"Gauge\"],\"articleSection\":[\"FactoryTalk View ME\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/\",\"name\":\"FactoryTalk View Gauge Object - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/image-55.png\",\"datePublished\":\"2020-12-13T21:08:58+00:00\",\"dateModified\":\"2020-12-14T11:17:13+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"We'll set up a FactoryTalk View Gauge Object to monitor a bearing temperature. We'll also set up Thresholds and define acceptable ranges.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/image-55.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/image-55.png\",\"width\":245,\"height\":203,\"caption\":\"Analog Gauge Display\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/13\\\/factorytalk-view-gauge\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"FactoryTalk View Gauge\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FactoryTalk View Gauge Object - Bryce Automation","description":"We'll set up a FactoryTalk View Gauge Object to monitor a bearing temperature. We'll also set up Thresholds and define acceptable ranges.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/","og_locale":"en_US","og_type":"article","og_title":"FactoryTalk View Gauge Object - Bryce Automation","og_description":"We'll set up a FactoryTalk View Gauge Object to monitor a bearing temperature. We'll also set up Thresholds and define acceptable ranges.","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-12-13T21:08:58+00:00","article_modified_time":"2020-12-14T11:17:13+00:00","og_image":[{"width":245,"height":203,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-55.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"FactoryTalk View Gauge","datePublished":"2020-12-13T21:08:58+00:00","dateModified":"2020-12-14T11:17:13+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/"},"wordCount":404,"commentCount":1,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-55.png","keywords":["Analog","Gauge"],"articleSection":["FactoryTalk View ME"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/","name":"FactoryTalk View Gauge Object - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-55.png","datePublished":"2020-12-13T21:08:58+00:00","dateModified":"2020-12-14T11:17:13+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"We'll set up a FactoryTalk View Gauge Object to monitor a bearing temperature. We'll also set up Thresholds and define acceptable ranges.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-55.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-55.png","width":245,"height":203,"caption":"Analog Gauge Display"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/13\/factorytalk-view-gauge\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"FactoryTalk View Gauge"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/5050","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=5050"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/5050\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/5058"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=5050"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=5050"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=5050"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}