{"id":5107,"date":"2020-12-14T13:50:17","date_gmt":"2020-12-14T13:50:17","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=5107"},"modified":"2020-12-14T13:50:18","modified_gmt":"2020-12-14T13:50:18","slug":"plc-5-to-controllogix-conversion","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/","title":{"rendered":"PLC-5 to ControlLogix Conversion"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">Introduction to PLC-5 to ControlLogix Conversion<\/h4>\n\n\n\n<p>RSLogix \/ Studio 5000 has a built in utility for PLC-5 to ControlLogix Conversion.  Likewise, we can use the same procedure for converting an SLC-500 project.  Because the PLC-5 is now obsolete, we will convert a PLC-5 project to use in a ControlLogix system.   The advantage is that we don&#8217;t have to re-write all of the logic.  The downside, however, is that we are not taking advantages of many ControlLogix features by doing this.  For example, your tags will still be address based.  In addition, some code might be redundant because you are not using <a href=\"https:\/\/bryceautomation.com\/index.php\/2017\/06\/12\/controllogix-add-on-instructions\/\">Add-On instructions<\/a> or <a href=\"https:\/\/bryceautomation.com\/index.php\/2017\/06\/03\/controllogix-udts\/\">UDT&#8217;s.<\/a>  Remember, this post is for example only.   The procedure will vary for your application.  You are responsible for taking all safety measures to prevent damage to equipment and personnel.<\/p><div id=\"bryce-1431311791\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h4 class=\"wp-block-heading\">PLC-5 Code<\/h4>\n\n\n\n<p>Consider the following project.  In this case, we have a switch that starts a timer.  When the timer is finished, the output will energize.  In short, this is a very simple PLC-5 project.  We will convert this to ControlLogix using Rockwell&#8217;s conversion utility.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"541\" height=\"250\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-65.png\" alt=\"\" class=\"wp-image-5108 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-65.png 541w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-65-300x139.png 300w\" data-sizes=\"(max-width: 541px) 100vw, 541px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 541px; --smush-placeholder-aspect-ratio: 541\/250;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Launch the PLC-5 to ControlLogix Conversion Utility<\/h4>\n\n\n\n<p>In Studio \/ RSLogix 5000, assuming the utility is installed, click on &#8220;Tools | Translate PLC-5\/SLC&#8221;<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"458\" height=\"370\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-66.png\" alt=\"\" class=\"wp-image-5109 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-66.png 458w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-66-300x242.png 300w\" data-sizes=\"(max-width: 458px) 100vw, 458px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 458px; --smush-placeholder-aspect-ratio: 458\/370;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Export the PLC-5 Project<\/h4>\n\n\n\n<p>Click on the image of the PLC-5 to Launch RSLogix 5.  Likewise, if you are converting an SLC project, be sure to click on the image of the SLC.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"399\" height=\"106\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-67.png\" alt=\"\" class=\"wp-image-5110 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-67.png 399w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-67-300x80.png 300w\" data-sizes=\"(max-width: 399px) 100vw, 399px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 399px; --smush-placeholder-aspect-ratio: 399\/106;\" \/><\/figure>\n\n\n\n<p>Open your PLC-5 project in RSLogix 5, then click &#8220;File | Save As&#8221;.  Be sure to save your project as a &#8220;.PC5&#8221; file.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"459\" height=\"339\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-68.png\" alt=\"\" class=\"wp-image-5111 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-68.png 459w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-68-300x222.png 300w\" data-sizes=\"(max-width: 459px) 100vw, 459px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 459px; --smush-placeholder-aspect-ratio: 459\/339;\" \/><\/figure>\n\n\n\n<p>In addition, we&#8217;ll do a complete save, and export all applicable files.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"400\" height=\"255\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-69.png\" alt=\"\" class=\"wp-image-5112 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-69.png 400w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-69-300x191.png 300w\" data-sizes=\"(max-width: 400px) 100vw, 400px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 400px; --smush-placeholder-aspect-ratio: 400\/255;\" \/><\/figure>\n\n\n\n<p>Close RSLogix 5, then browse for the .PC5 file you just exported.  Click &#8220;Next&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"521\" height=\"553\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-70.png\" alt=\"\" class=\"wp-image-5114 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-70.png 521w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-70-283x300.png 283w\" data-sizes=\"(max-width: 521px) 100vw, 521px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 521px; --smush-placeholder-aspect-ratio: 521\/553;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Import the file as ControlLogix<\/h4>\n\n\n\n<p>Secondly, specify the output file.  You will also specify the type of ControlLogix processor, and the revision.  Click &#8220;Next&#8221;.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"434\" height=\"215\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-71.png\" alt=\"\" class=\"wp-image-5115 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-71.png 434w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-71-300x149.png 300w\" data-sizes=\"(max-width: 434px) 100vw, 434px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 434px; --smush-placeholder-aspect-ratio: 434\/215;\" \/><\/figure>\n\n\n\n<p>At this point, we&#8217;ll specify what aliases to create.  The Aliases will allow us to point the old tag names to the new I\/O Locations once our project is complete.    Remember that Aliases are just another name for a tag.  You can also think of them as &#8220;Shortcuts&#8221; to another tag.   <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"393\" height=\"149\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-72.png\" alt=\"\" class=\"wp-image-5116 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-72.png 393w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-72-300x114.png 300w\" data-sizes=\"(max-width: 393px) 100vw, 393px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 393px; --smush-placeholder-aspect-ratio: 393\/149;\" \/><\/figure>\n\n\n\n<p>Fourthly, allow the project to translate, then launch RSLogix \/ Studio 5000.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"491\" height=\"333\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-73.png\" alt=\"\" class=\"wp-image-5117 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-73.png 491w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-73-300x203.png 300w\" data-sizes=\"(max-width: 491px) 100vw, 491px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 491px; --smush-placeholder-aspect-ratio: 491\/333;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Open your new project in RSLogix \/ Studio 5000<\/h4>\n\n\n\n<p>Now that your project is created, open the project in RSLogix \/ Studio 5000.  this is an L5K project, so Studio 5000 will ask to import this file.<\/p>\n\n\n\n<p>Open your ladder, and you will see that the project is translated.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"723\" height=\"498\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-74.png\" alt=\"\" class=\"wp-image-5118 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-74.png 723w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-74-300x207.png 300w\" data-sizes=\"(max-width: 723px) 100vw, 723px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 723px; --smush-placeholder-aspect-ratio: 723\/498;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Add I\/O Modules<\/h4>\n\n\n\n<p>At the bottom of the I\/O tree, add your I\/O Modules to the I\/O Configuration tree.   In this case, we just have an input module in slot 5, and an output module in slot 6.  If you are unsure how to do this, read up on how to add <a href=\"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/controllogix-local-io\/\">Local I\/O<\/a> and <a href=\"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/controllogix-ethernet-io\/\">Remote I\/O.<\/a><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"301\" height=\"102\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-76.png\" alt=\"\" class=\"wp-image-5120 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 301px; --smush-placeholder-aspect-ratio: 301\/102;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Map the Real I\/O for PLC-5 to ControlLogix Conversion<\/h4>\n\n\n\n<p>Finally, map the I\/O bits to the real ControlLogix I\/O Tags.  Take special care while doing this.   Incorrect mapping could have disastrous results.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"586\" height=\"381\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-75.png\" alt=\"\" class=\"wp-image-5119 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-75.png 586w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-75-300x195.png 300w\" data-sizes=\"(max-width: 586px) 100vw, 586px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 586px; --smush-placeholder-aspect-ratio: 586\/381;\" \/><\/figure>\n<div id=\"bryce-1693828460\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to PLC-5 to ControlLogix Conversion RSLogix \/ Studio 5000 has a built in utility for PLC-5 to ControlLogix Conversion. Likewise, we can use the same procedure for converting an SLC-500 project. Because the PLC-5 is now obsolete, we will convert a PLC-5 project to use in a ControlLogix system. The advantage is that we <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":5118,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4,167,130],"tags":[278,279,280],"class_list":{"0":"post-5107","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-controllogix","8":"category-plc-5","9":"category-slc500","10":"tag-conversion","11":"tag-plc-5-to-controllogix","12":"tag-slc-500-to-controllogix","13":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>PLC-5 to ControlLogix Conversion - Bryce Automation<\/title>\n<meta name=\"description\" content=\"PLC-5 to ControlLogix Conversion to translate a PLC-5 project to ControlLogix. This procedure will also work with the SLC-500.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PLC-5 to ControlLogix Conversion - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"PLC-5 to ControlLogix Conversion to translate a PLC-5 project to ControlLogix. This procedure will also work with the SLC-500.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-12-14T13:50:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-12-14T13:50:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-74.png\" \/>\n\t<meta property=\"og:image:width\" content=\"723\" \/>\n\t<meta property=\"og:image:height\" content=\"498\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"PLC-5 to ControlLogix Conversion\",\"datePublished\":\"2020-12-14T13:50:17+00:00\",\"dateModified\":\"2020-12-14T13:50:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/\"},\"wordCount\":512,\"commentCount\":3,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/image-74.png\",\"keywords\":[\"conversion\",\"plc-5 to controllogix\",\"slc-500 to controllogix\"],\"articleSection\":[\"ControlLogix\",\"PLC-5\",\"SLC500\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/\",\"name\":\"PLC-5 to ControlLogix Conversion - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/image-74.png\",\"datePublished\":\"2020-12-14T13:50:17+00:00\",\"dateModified\":\"2020-12-14T13:50:18+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"PLC-5 to ControlLogix Conversion to translate a PLC-5 project to ControlLogix. This procedure will also work with the SLC-500.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/image-74.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/image-74.png\",\"width\":723,\"height\":498,\"caption\":\"PLC-5 Conversion\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/14\\\/plc-5-to-controllogix-conversion\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PLC-5 to ControlLogix Conversion\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PLC-5 to ControlLogix Conversion - Bryce Automation","description":"PLC-5 to ControlLogix Conversion to translate a PLC-5 project to ControlLogix. This procedure will also work with the SLC-500.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/","og_locale":"en_US","og_type":"article","og_title":"PLC-5 to ControlLogix Conversion - Bryce Automation","og_description":"PLC-5 to ControlLogix Conversion to translate a PLC-5 project to ControlLogix. This procedure will also work with the SLC-500.","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-12-14T13:50:17+00:00","article_modified_time":"2020-12-14T13:50:18+00:00","og_image":[{"width":723,"height":498,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-74.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"PLC-5 to ControlLogix Conversion","datePublished":"2020-12-14T13:50:17+00:00","dateModified":"2020-12-14T13:50:18+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/"},"wordCount":512,"commentCount":3,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-74.png","keywords":["conversion","plc-5 to controllogix","slc-500 to controllogix"],"articleSection":["ControlLogix","PLC-5","SLC500"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/","name":"PLC-5 to ControlLogix Conversion - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-74.png","datePublished":"2020-12-14T13:50:17+00:00","dateModified":"2020-12-14T13:50:18+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"PLC-5 to ControlLogix Conversion to translate a PLC-5 project to ControlLogix. This procedure will also work with the SLC-500.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-74.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-74.png","width":723,"height":498,"caption":"PLC-5 Conversion"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/14\/plc-5-to-controllogix-conversion\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"PLC-5 to ControlLogix Conversion"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/5107","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=5107"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/5107\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/5118"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=5107"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=5107"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=5107"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}