{"id":5180,"date":"2020-12-15T18:42:53","date_gmt":"2020-12-15T18:42:53","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=5180"},"modified":"2020-12-15T18:42:54","modified_gmt":"2020-12-15T18:42:54","slug":"controllogix-bit-field-distributor","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/","title":{"rendered":"ControlLogix Bit Field Distributor"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">Introduction to the ControlLogix Bit Field Distributor (BTD)<\/h4>\n\n\n\n<p>The ControlLogix Bit Field Distributor (BTD) Allows us to map bits from one word to another.  Particularly, when converting 32 bit data to 16 bit data, the BTD makes this very easy.  In this case, we have a 32 bit input module.  For the purpose of this document, we&#8217;ll assume that our SCADA system can only handle 16 bit data.   In this case, we&#8217;ll take the first 16 bits, and map the data to the Input16a tag.  Likewise, we&#8217;ll map the last 16 bits to the Input16b tag.  We&#8217;ve also used this in RFID readers, where the data is in simple 8 bit format, or even on DeviceNet to remap data from a field device so the bits in the word will match up with the labels on the field device.<\/p><div id=\"bryce-3131805472\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<p>Another use for the BTD is to convert data into 16 bit format before sending it to the SLC or PLC-5.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"517\" height=\"112\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-82.png\" alt=\"\" class=\"wp-image-5181 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-82.png 517w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-82-300x65.png 300w\" data-sizes=\"(max-width: 517px) 100vw, 517px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 517px; --smush-placeholder-aspect-ratio: 517\/112;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">Add the First ControlLogix Bit Field Distributor<\/h4>\n\n\n\n<p>To demonstrate, I&#8217;ll just add the BTD Instruction to rung 0 of the main routine.   I&#8217;ll leave this instruction as unconditional.  In other words, the instruction will execute every scan.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"384\" height=\"232\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-83.png\" alt=\"\" class=\"wp-image-5182 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-83.png 384w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-83-300x181.png 300w\" data-sizes=\"(max-width: 384px) 100vw, 384px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 384px; --smush-placeholder-aspect-ratio: 384\/232;\" \/><\/figure>\n\n\n\n<p>Notice that our source is Input32, and the destination tag is Input16a.  For the first BTD, we&#8217;re taking data from bit 0 of Input32, and placing that data into Input16a starting at bit 0.  Our length is 16.  In other words, we are copying 16 bits.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Add the Second ControlLogix Bit Field Distributor<\/h4>\n\n\n\n<p>At this point, we only have 16 bits of data moved.   We still need to move the last 16 bits of Input32 into the Input16a tag.  To illustrate, look at the example below.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"357\" height=\"237\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-84.png\" alt=\"\" class=\"wp-image-5183 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-84.png 357w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-84-300x199.png 300w\" data-sizes=\"(max-width: 357px) 100vw, 357px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 357px; --smush-placeholder-aspect-ratio: 357\/237;\" \/><\/figure>\n\n\n\n<p>Notice that our source is still Input32.  However, this time, our destination is Input16b.  We are starting at bit 16 of Input32 this time.  We are copying the last 16 bits of Input32 into the Input16a tag.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">Test your work<\/h4>\n\n\n\n<p>Let&#8217;s finalize your edits, and execute the instructions.  We&#8217;ll see how our data changes.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"523\" height=\"173\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-85.png\" alt=\"\" class=\"wp-image-5184 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-85.png 523w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-85-300x99.png 300w\" data-sizes=\"(max-width: 523px) 100vw, 523px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 523px; --smush-placeholder-aspect-ratio: 523\/173;\" \/><\/figure>\n\n\n\n<p>Notice your data converted exactly as we would expect!<\/p>\n\n\n\n<p>For other information on ControlLogix, please visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/controllogix\/\">Category Page!<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-1236324534\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction to the ControlLogix Bit Field Distributor (BTD) The ControlLogix Bit Field Distributor (BTD) Allows us to map bits from one word to another. Particularly, when converting 32 bit data to 16 bit data, the BTD makes this very easy. In this case, we have a 32 bit input module. For the purpose of this <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":5183,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[281],"class_list":{"0":"post-5180","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-controllogix","8":"tag-btd","9":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ControlLogix Bit Field Distributor (BTD) - Bryce Automation<\/title>\n<meta name=\"description\" content=\"Using the ControlLogix Bit Field Distributor (BTD) Instruction to convert 32 bit data to 16 bit words for use in SCADA, PLC-5, or SLC-500.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ControlLogix Bit Field Distributor (BTD) - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"Using the ControlLogix Bit Field Distributor (BTD) Instruction to convert 32 bit data to 16 bit words for use in SCADA, PLC-5, or SLC-500.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2020-12-15T18:42:53+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2020-12-15T18:42:54+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-84.png\" \/>\n\t<meta property=\"og:image:width\" content=\"357\" \/>\n\t<meta property=\"og:image:height\" content=\"237\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"ControlLogix Bit Field Distributor\",\"datePublished\":\"2020-12-15T18:42:53+00:00\",\"dateModified\":\"2020-12-15T18:42:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/\"},\"wordCount\":362,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/image-84.png\",\"keywords\":[\"BTD\"],\"articleSection\":[\"ControlLogix\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/\",\"name\":\"ControlLogix Bit Field Distributor (BTD) - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/image-84.png\",\"datePublished\":\"2020-12-15T18:42:53+00:00\",\"dateModified\":\"2020-12-15T18:42:54+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"Using the ControlLogix Bit Field Distributor (BTD) Instruction to convert 32 bit data to 16 bit words for use in SCADA, PLC-5, or SLC-500.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/image-84.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2020\\\/12\\\/image-84.png\",\"width\":357,\"height\":237,\"caption\":\"BTD\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2020\\\/12\\\/15\\\/controllogix-bit-field-distributor\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ControlLogix Bit Field Distributor\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ControlLogix Bit Field Distributor (BTD) - Bryce Automation","description":"Using the ControlLogix Bit Field Distributor (BTD) Instruction to convert 32 bit data to 16 bit words for use in SCADA, PLC-5, or SLC-500.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/","og_locale":"en_US","og_type":"article","og_title":"ControlLogix Bit Field Distributor (BTD) - Bryce Automation","og_description":"Using the ControlLogix Bit Field Distributor (BTD) Instruction to convert 32 bit data to 16 bit words for use in SCADA, PLC-5, or SLC-500.","og_url":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2020-12-15T18:42:53+00:00","article_modified_time":"2020-12-15T18:42:54+00:00","og_image":[{"width":357,"height":237,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-84.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"ControlLogix Bit Field Distributor","datePublished":"2020-12-15T18:42:53+00:00","dateModified":"2020-12-15T18:42:54+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/"},"wordCount":362,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-84.png","keywords":["BTD"],"articleSection":["ControlLogix"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/","url":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/","name":"ControlLogix Bit Field Distributor (BTD) - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-84.png","datePublished":"2020-12-15T18:42:53+00:00","dateModified":"2020-12-15T18:42:54+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"Using the ControlLogix Bit Field Distributor (BTD) Instruction to convert 32 bit data to 16 bit words for use in SCADA, PLC-5, or SLC-500.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-84.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2020\/12\/image-84.png","width":357,"height":237,"caption":"BTD"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2020\/12\/15\/controllogix-bit-field-distributor\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"ControlLogix Bit Field Distributor"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/5180","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=5180"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/5180\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/5183"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=5180"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=5180"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=5180"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}