{"id":565,"date":"2017-05-26T22:34:42","date_gmt":"2017-05-26T22:34:42","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=565"},"modified":"2022-09-21T10:03:17","modified_gmt":"2022-09-21T10:03:17","slug":"rslinx-df1-driver","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/","title":{"rendered":"RSLinx DF1 Driver"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">Configuring the RSLinx DF1 Driver<\/h2>\n\n\n\n<p>In this section, we&#8217;ll set up the RSLinx DF1 Driver.&nbsp; Communications is very important in Industrial Automation. &nbsp; &nbsp;If you cannot communicate, you cannot go online to troubleshoot or change the program in your system. &nbsp; This document will guide you through Configuring the DF1 Driver in RSLinx. &nbsp; RSLinx is the <strong>communication server<\/strong> that interfaces between your processor and RSLogix\/Studio 5000. &nbsp; We will use the same procedure to an SLC5\/03 or higher, Micrologix, or PLC-5. &nbsp;The ControlLogix L6x or earlier has a serial port by&nbsp;you can communicate using the DF1 Driver.<\/p><div id=\"bryce-3091430677\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">What you will need:<\/h2>\n\n\n\n<p>To communicate with your ControlLogix system, you will need a 1756-CP3 cable (or other null modem cable). &nbsp;You will also need RSLogix\/Studio 5000 installed on your computer with RSLinx, and an available RS232 port on your PC. &nbsp;New computers are not usually equipped with an RS232 port, so you can use a USB to Serial adapter.  Just make sure to install the drivers for your adapter if you haven&#8217;t already.<\/p>\n\n\n\n<p>Beware of some serial adapters under Windows 10.  If you happened to get a &#8220;fake&#8221; FTDI chip in your serial adapter, it may not work at all under Windows 10.  It&#8217;s my understanding that for a while, the FTDI driver would disable the fake chip in your adapter.  After that, the new driver caused the fake chip to just transmit garbage.  This could cause damage to equipment and personnel.  <\/p>\n\n\n\n<p>Since there were so many fake FTDI chips on the market, it might be difficult to determine if you have the genuine or fake chip in your adapter. <a href=\"https:\/\/www.zdnet.com\/article\/ftdi-admits-to-bricking-innocent-users-chips-in-silent-update\/\">Read this article<\/a> for more information.  I&#8217;ve had trouble with some of the Prolific chips under Windows 10 as well.  If you have this issue, you may be able to downgrade your windows driver.<\/p>\n\n\n\n<p>If you are using a Micrologix 1000, please use a 1761-CBL-PM02 cable. &nbsp;If you are connecting to a PLC-5, realize that the PLC-5 has a 25pin RS232 port, so you may need a 9 to 25 pin adapter. .  <\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1) &nbsp;Open RSLinx Communication server<\/h2>\n\n\n\n<p>Access RSLinx at it&#8217;s default location, which is under Start | All Programs | Rockwell Software | RSLinx | RSLinx Classic. &nbsp;If your computer has a shortcut on the desktop to access RSLinx, you will see the following icon:<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"198\" height=\"144\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rslinxopen.png\" alt=\"RSLinx Open\" class=\"wp-image-566 lazyload\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 198px; --smush-placeholder-aspect-ratio: 198\/144;\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">2) &nbsp;Go to the &#8220;Configure Drivers&#8221; screen<\/h2>\n\n\n\n<p>Next, we will click on Communications | Configure Drivers within RSLinx. &nbsp; A driver is just a set of instructions that tell your software how to interface with the hardware.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"300\" height=\"90\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rslinxconfiguredrivers-300x90.png\" alt=\"RSLinxConfigureDrivers\" class=\"wp-image-567 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rslinxconfiguredrivers-300x90.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rslinxconfiguredrivers.png 495w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/90;\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">3) &nbsp;Choose &#8220;RS232 DF1 Devices&#8221;<\/h2>\n\n\n\n<p>The list of drivers can look very intimidating, but keep in mind that there are probably only a few drivers on the list that you may need to be concerned with for your location. &nbsp; Of course we&nbsp;need to choose the RS232 DF1 Devices driver.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"859\" height=\"164\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rs232df1devices.png\" alt=\"RS232 DF1 Devices\" class=\"wp-image-568 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rs232df1devices.png 859w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rs232df1devices-300x57.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rs232df1devices-768x147.png 768w\" data-sizes=\"(max-width: 859px) 100vw, 859px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 859px; --smush-placeholder-aspect-ratio: 859\/164;\" \/><\/figure>\n<\/div>\n\n\n<p>Next, you will be prompted to enter a name for the driver. &nbsp; Here, we can just hit OK.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"300\" height=\"113\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/RSLinxDF1NameOK-300x113.png\" alt=\"RSLinxDF1NameOK\" class=\"wp-image-569 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/RSLinxDF1NameOK-300x113.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/RSLinxDF1NameOK.png 549w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/113;\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">4) &nbsp;Configure the RSLinx DF1 Driver<\/h2>\n\n\n\n<p>RSLinx makes this step very easy. &nbsp; We do need to know which COM port your RS232 port is appearing at though. &nbsp; &nbsp;If you are unsure of this, go to your &#8220;Device Manager&#8221; in Windows. &nbsp; Then, press the + next to ports, then you will see the COM Ports that are available. &nbsp; &nbsp;In our case, the port is COM1. &nbsp;As long as you are connected to the processor, and the port is set at DF1 (which is default), you should have no problem using the Autoconfiguration feature. &nbsp;Finally, press the Autoconfig button, and you should get a message that the Autoconfiguration completed successfully. &nbsp;Finally, press OK, and close the &#8220;Configure Drivers&#8221; screen.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"300\" height=\"295\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/RSLinxDF1Configuration-300x295.png\" alt=\"RSLinx DF1 Configuration\" class=\"wp-image-580 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/RSLinxDF1Configuration-300x295.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/RSLinxDF1Configuration.png 630w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/295;\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">5) &nbsp;Verify Communication through the RSLinx DF1 Driver<\/h2>\n\n\n\n<p>Of course to make sure you are communicating, go to the RSWho Screen. &nbsp;The RSWHO screen will verify communication.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"300\" height=\"131\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rswhoicon-300x131.png\" alt=\"RSWhoIcon\" class=\"wp-image-570 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rswhoicon-300x131.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rswhoicon.png 388w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/131;\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-left\">Next, select the DF1 Driver on the left side of your screen.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" width=\"300\" height=\"99\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rswhoprocessor-300x99.png\" alt=\"RSWho processor\" class=\"wp-image-571 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rswhoprocessor-300x99.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/rswhoprocessor.png 724w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/99;\" \/><\/figure>\n<\/div>\n\n\n<p>Consequently, you will see your processor appear on the right side of the screen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Summary of RSLinx DF1 Driver<\/h2>\n\n\n\n<p>In short, the RSLinx DF1 Driver is very simple to set up.  You just need a working COM port, and a Null Modem cable.  Additionally, just go to Device Manager to see what COM port the serial port appears on.  After that, add a DF1 Driver, set the COM Port and AutoConfig.  In some versions, you may need to choose the correct processor type first.  The AutoConfig feature automatically finds the correct communication parameters.  Next, just go to RSWho to verify communication.<\/p>\n\n\n\n<p>For more information, visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/slc500\/\">SLC-500<\/a> or <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/controllogix\/\">ControlLogix<\/a> Category Page.<\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n\n\n\n<p><\/p>\n<div id=\"bryce-3731812287\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Configuring the RSLinx DF1 Driver In this section, we&#8217;ll set up the RSLinx DF1 Driver.&nbsp; Communications is very important in Industrial Automation. &nbsp; &nbsp;If you cannot communicate, you cannot go online to troubleshoot or change the program in your system. &nbsp; This document will guide you through Configuring the DF1 Driver in RSLinx. &nbsp; RSLinx <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":580,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":{"0":"post-565","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-controllogix","8":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to configure the RSLinx DF1 Driver (RS232 DF1 Devices)<\/title>\n<meta name=\"description\" content=\"Step by step instructions on how to find your serial port, and to set up communication to your ControlLogix processor the RSLinx DF1 Driver.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to configure the RSLinx DF1 Driver (RS232 DF1 Devices)\" \/>\n<meta property=\"og:description\" content=\"Step by step instructions on how to find your serial port, and to set up communication to your ControlLogix processor the RSLinx DF1 Driver.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2017-05-26T22:34:42+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-09-21T10:03:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/RSLinxDF1Configuration.png\" \/>\n\t<meta property=\"og:image:width\" content=\"630\" \/>\n\t<meta property=\"og:image:height\" content=\"619\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"RSLinx DF1 Driver\",\"datePublished\":\"2017-05-26T22:34:42+00:00\",\"dateModified\":\"2022-09-21T10:03:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/\"},\"wordCount\":779,\"commentCount\":1,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/RSLinxDF1Configuration.png\",\"articleSection\":[\"ControlLogix\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/\",\"name\":\"How to configure the RSLinx DF1 Driver (RS232 DF1 Devices)\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/RSLinxDF1Configuration.png\",\"datePublished\":\"2017-05-26T22:34:42+00:00\",\"dateModified\":\"2022-09-21T10:03:17+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"Step by step instructions on how to find your serial port, and to set up communication to your ControlLogix processor the RSLinx DF1 Driver.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/RSLinxDF1Configuration.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/RSLinxDF1Configuration.png\",\"width\":630,\"height\":619,\"caption\":\"RSLinx DF1 Configuration\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/26\\\/rslinx-df1-driver\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"RSLinx DF1 Driver\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to configure the RSLinx DF1 Driver (RS232 DF1 Devices)","description":"Step by step instructions on how to find your serial port, and to set up communication to your ControlLogix processor the RSLinx DF1 Driver.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/","og_locale":"en_US","og_type":"article","og_title":"How to configure the RSLinx DF1 Driver (RS232 DF1 Devices)","og_description":"Step by step instructions on how to find your serial port, and to set up communication to your ControlLogix processor the RSLinx DF1 Driver.","og_url":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2017-05-26T22:34:42+00:00","article_modified_time":"2022-09-21T10:03:17+00:00","og_image":[{"width":630,"height":619,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/RSLinxDF1Configuration.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"RSLinx DF1 Driver","datePublished":"2017-05-26T22:34:42+00:00","dateModified":"2022-09-21T10:03:17+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/"},"wordCount":779,"commentCount":1,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/RSLinxDF1Configuration.png","articleSection":["ControlLogix"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/","url":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/","name":"How to configure the RSLinx DF1 Driver (RS232 DF1 Devices)","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/RSLinxDF1Configuration.png","datePublished":"2017-05-26T22:34:42+00:00","dateModified":"2022-09-21T10:03:17+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"Step by step instructions on how to find your serial port, and to set up communication to your ControlLogix processor the RSLinx DF1 Driver.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/RSLinxDF1Configuration.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/RSLinxDF1Configuration.png","width":630,"height":619,"caption":"RSLinx DF1 Configuration"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/26\/rslinx-df1-driver\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"RSLinx DF1 Driver"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/565","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=565"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/565\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/580"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=565"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=565"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=565"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}