{"id":605,"date":"2017-05-27T11:56:17","date_gmt":"2017-05-27T11:56:17","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=605"},"modified":"2017-05-27T23:36:58","modified_gmt":"2017-05-27T23:36:58","slug":"starting-project-studio-5000","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/","title":{"rendered":"Starting a Project in Studio 5000"},"content":{"rendered":"<h2>\u00a0Starting a Project (from scratch) in Studio 5000<\/h2>\n<p>When you are starting a project in Studio 5000, you are building a new project from scratch. \u00a0 Many of you will need to do this if you have a unit set up in your shop. \u00a0At times, you will\u00a0want to try some logic in a &#8220;sandbox&#8221; before implementing changes on production equipment. \u00a0 The procedure for setting up a project is easy, but there are some things we will need to know. \u00a0You will need the catalog number of your processor, the revision of the processor, your chassis size, and the number of slots in your chassis.<\/p><div id=\"bryce-3173768032\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n<p>If this is a brand new processor, you will flash the processor to the revision of your project before you download. \u00a0 \u00a0Studio 5000 will prompt you to do this on the first download. \u00a0 If the processor is unsealed, then someone else has probably already set a revision in the processor. \u00a0You can find this revision in the processor&#8217;s properties in RSLinx. \u00a0 Another method to find the revision is to use your web browser. \u00a0 If you are on the same network as your chassis, just enter the IP address of your processor or Ethernet module. \u00a0The IP address will scroll across the front of the module. \u00a0 Next, you can &#8220;Browse Chassis&#8221; if you have a separate Ethernet module to find the processor&#8217;s revision.<\/p>\n<h2>Open Studio 5000<\/h2>\n<p><img decoding=\"async\" class=\"alignright size-medium wp-image-606 lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio1-300x163.png\" alt=\"Studio 5000 Splash Screen\" width=\"300\" height=\"163\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio1-300x163.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio1.png 646w\" data-sizes=\"(max-width: 300px) 100vw, 300px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 300px; --smush-placeholder-aspect-ratio: 300\/163;\" \/>Studio 5000 is under Start | All Programs | Rockwell Software. \u00a0 Older versions (prior to 21) are called RSLogix 5000. \u00a0Once Studio 5000 is open, we will create a new project. \u00a0 If this menu does not appear, you can create a new project by clicking &#8220;File&#8221; on the menu bar.<\/p>\n<p>&nbsp;<\/p>\n<h2>Processor Information<\/h2>\n<p>Next, we will need to enter information about our processor. \u00a0 Select the model of your processor, and give your project a name. \u00a0 Here we will name the project &#8220;MyNewProject&#8221;.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-607 size-full lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio2.png\" alt=\"Studio New Project\" width=\"595\" height=\"478\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio2.png 595w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio2-300x241.png 300w\" data-sizes=\"(max-width: 595px) 100vw, 595px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 595px; --smush-placeholder-aspect-ratio: 595\/478;\" \/><\/p>\n<p>Now, be sure to select the proper revision, processor name, chassis size, and processor slot. \u00a0 Recall that if the processor already has a revision, we an get this revision by using the RSWHO screen in RSLinx, or our web browser.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-608 size-full lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/studio3.png\" alt=\"Select Processor Studio\" width=\"595\" height=\"473\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/studio3.png 595w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/studio3-300x238.png 300w\" data-sizes=\"(max-width: 595px) 100vw, 595px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 595px; --smush-placeholder-aspect-ratio: 595\/473;\" \/><\/p>\n<p>Finally, you can press &#8220;Finish&#8221;. \u00a0 This will build our project, and you will see the Studio 5000 IDE (Integrated Development Environment). \u00a0 Let&#8217;s discuss the names of the different toolbars. \u00a0 By knowing the names of the different toolbars, this will help us in other parts of this documentation. \u00a0 Also, if you accidentally remove a toolbar, you will need to know the name of the toolbar to get it back under View | toolbars.<\/p>\n<h2>Logix Designer Toolbars<\/h2>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-609 size-full lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/studio4.png\" alt=\"Studio 5000 Toolbars\" width=\"1004\" height=\"161\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/studio4.png 1004w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/studio4-300x48.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/studio4-768x123.png 768w\" data-sizes=\"(max-width: 1004px) 100vw, 1004px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 1004px; --smush-placeholder-aspect-ratio: 1004\/161;\" \/><\/p>\n<p>At the very top of the IDE is the Title Bar which displays information about your project, such as the name and processor type. \u00a0Underneath the Title Bar, you will find the Menu Bar. \u00a0Then underneath the menu bar, is the standard toolbar with some standard icons. \u00a0 These toolbars are very common among many windows applications.<\/p>\n<p>On the left (at the bottom of the image), you will find the Online toolbar. \u00a0 This tells us if we are online or offline. \u00a0 When online, we are actively communicating with the processor, and the status of the processor will be displayed. \u00a0This will reflect Run, Prog, Rem Run, Rem Prog, Faulted, or if we are in Test mode. \u00a0It will also display if we have forces in the processor, pending edits, and the status of the I\/O.<\/p>\n<p>You will find the Instruction toolbar to the right of the online toolbar. \u00a0 \u00a0These are instructions that we can drag down into our logic to make things happen.<\/p>\n<h2>Communication Path<\/h2>\n<p>At the right is the Path bar which displays the communication path from our laptop to our processor. \u00a0 If no path has been established yet, be sure your necessary drivers are configured in RSLinx, and go to Communications | Who active. \u00a0 Now, you can\u00a0browse for your PROCESSOR and select the path. \u00a0 Be sure to select the proper path to your PROCESSOR. \u00a0 A common problem is that most people will select an Ethernet module, such as a 1756-ENBT or 1756-EN2T, and cannot download to the processor. \u00a0 Be sure to drill through the Ethernet module, across the backplane to get to your processor. \u00a0If you are communicating over DF1 or USB, then your processor is the first module you will come to. \u00a0If you have the 1756-L8x, then your ethernet port is built onto your processor, so the processor is the first module you come to under the Ethernet Driver.<\/p>\n<h2>Controller Organizer<\/h2>\n<p><img decoding=\"async\" class=\"size-medium wp-image-610 alignleft lazyload\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio5-233x300.png\" alt=\"Controller Organizer\" width=\"233\" height=\"300\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio5-233x300.png 233w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio5.png 297w\" data-sizes=\"(max-width: 233px) 100vw, 233px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 233px; --smush-placeholder-aspect-ratio: 233\/300;\" \/><\/p>\n<p>The Controller Organizer window displays information about the project that you will download to your processor. \u00a0There are two main divisions of the processor&#8217;s memory: \u00a0Tags and Tasks. \u00a0 Tags store data, and Tasks contain the logic that manipulates your data.<\/p>\n<p>On a default project, there are no tags whatsoever. \u00a0 However, as you add modules to the I\/O Configuration, Studio 5000 will build tags that are associated with those modules. \u00a0 \u00a0You will also create other tags for timers, counters, and internal BOOL bits. \u00a0 Controller tags are global, meaning any program or any controller can access the tags. \u00a0There are also program tags (within a program) that are local to the program they reside in.<\/p>\n<p>At the bottom of the Controller Organizer window is the I\/O Configuration tree. \u00a0Here, we will add all of the I\/O or other processors that we will be communicating with.<\/p>\n<p>To view other documents on the ControlLogix system, check out the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/controllogix\/\">ControlLogix <\/a>category on this site!<\/p>\n<div id=\"bryce-4190292482\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>\u00a0Starting a Project (from scratch) in Studio 5000 When you are starting a project in Studio 5000, you are building a new project from scratch. \u00a0 Many of you will need to do this if you have a unit set up in your shop. \u00a0At times, you will\u00a0want to try some logic in a &#8220;sandbox&#8221; <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":606,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[],"class_list":{"0":"post-605","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-controllogix","8":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Starting a project in Studio 5000, and choosing your processor<\/title>\n<meta name=\"description\" content=\"How to start a new project in Studio 5000, and choose the processor, chassis size, firmware revision, and processor slot.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Starting a project in Studio 5000, and choosing your processor\" \/>\n<meta property=\"og:description\" content=\"How to start a new project in Studio 5000, and choose the processor, chassis size, firmware revision, and processor slot.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2017-05-27T11:56:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2017-05-27T23:36:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"646\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"Starting a Project in Studio 5000\",\"datePublished\":\"2017-05-27T11:56:17+00:00\",\"dateModified\":\"2017-05-27T23:36:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/\"},\"wordCount\":902,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/Studio1.png\",\"articleSection\":[\"ControlLogix\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/\",\"name\":\"Starting a project in Studio 5000, and choosing your processor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/Studio1.png\",\"datePublished\":\"2017-05-27T11:56:17+00:00\",\"dateModified\":\"2017-05-27T23:36:58+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"How to start a new project in Studio 5000, and choose the processor, chassis size, firmware revision, and processor slot.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/Studio1.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2017\\\/05\\\/Studio1.png\",\"width\":646,\"height\":350,\"caption\":\"Studio 5000 Splash Screen\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2017\\\/05\\\/27\\\/starting-project-studio-5000\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Starting a Project in Studio 5000\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Starting a project in Studio 5000, and choosing your processor","description":"How to start a new project in Studio 5000, and choose the processor, chassis size, firmware revision, and processor slot.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/","og_locale":"en_US","og_type":"article","og_title":"Starting a project in Studio 5000, and choosing your processor","og_description":"How to start a new project in Studio 5000, and choose the processor, chassis size, firmware revision, and processor slot.","og_url":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2017-05-27T11:56:17+00:00","article_modified_time":"2017-05-27T23:36:58+00:00","og_image":[{"width":646,"height":350,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio1.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"Starting a Project in Studio 5000","datePublished":"2017-05-27T11:56:17+00:00","dateModified":"2017-05-27T23:36:58+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/"},"wordCount":902,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio1.png","articleSection":["ControlLogix"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/","url":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/","name":"Starting a project in Studio 5000, and choosing your processor","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio1.png","datePublished":"2017-05-27T11:56:17+00:00","dateModified":"2017-05-27T23:36:58+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"How to start a new project in Studio 5000, and choose the processor, chassis size, firmware revision, and processor slot.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio1.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2017\/05\/Studio1.png","width":646,"height":350,"caption":"Studio 5000 Splash Screen"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2017\/05\/27\/starting-project-studio-5000\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"Starting a Project in Studio 5000"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/605","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=605"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/605\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/606"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=605"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=605"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=605"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}