{"id":6063,"date":"2021-02-04T12:45:59","date_gmt":"2021-02-04T12:45:59","guid":{"rendered":"http:\/\/bryceautomation.com\/?p=6063"},"modified":"2021-02-04T12:45:59","modified_gmt":"2021-02-04T12:45:59","slug":"cant-download-to-faulted-controller","status":"publish","type":"post","link":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/","title":{"rendered":"Can&#8217;t Download to Faulted Controller"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">Introduction: &#8220;Can&#8217;t Download to Faulted Controller&#8221;<\/h4>\n\n\n\n<p>If you get the error &#8220;Can&#8217;t Download to Faulted Controller&#8221;, we need to clear the fault before downloading.   First of all, be sure you want to download to the processor.  When you download, the existing logic is replaced by the logic in your offline project.   <\/p><div id=\"bryce-452392205\" class=\"bryce-afterfirst bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"7728240895\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>\n\n\n\n<p>It&#8217;s  important to realize that we need to get a description of the fault.  That way, we can try to prevent the fault from happening again in the future.  This Error is 734-8004204F.<\/p>\n\n\n\n<p>Always realize that when you clear the fault and go back to run mode, unexpected motion may occur.   It&#8217;s your responsibility to take all safety precautions.  This document is an example only of how to clear a fault.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"537\" height=\"158\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-24.png\" alt=\"\" class=\"wp-image-6069 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-24.png 537w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-24-300x88.png 300w\" data-sizes=\"(max-width: 537px) 100vw, 537px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 537px; --smush-placeholder-aspect-ratio: 537\/158;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">If your offline file does not match the processor logic<\/h4>\n\n\n\n<p>If your ACD does not match the logic in the processor, simply attempt to go online with the controller.  Obviously, you already have the path set, because RSLogix \/ Studio 5000 knows we have a controller fault.  If you already know why the controller faulted, and just want to clear the fault, simply go to &#8220;Major Faults&#8221;.  At this time, clear the major errors, then download.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"651\" height=\"395\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-26.png\" alt=\"\" class=\"wp-image-6071 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-26.png 651w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-26-300x182.png 300w\" data-sizes=\"(max-width: 651px) 100vw, 651px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 651px; --smush-placeholder-aspect-ratio: 651\/395;\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"547\" height=\"45\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-27.png\" alt=\"\" class=\"wp-image-6072 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-27.png 547w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-27-300x25.png 300w\" data-sizes=\"(max-width: 547px) 100vw, 547px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 547px; --smush-placeholder-aspect-ratio: 547\/45;\" \/><\/figure>\n\n\n\n<h4 class=\"wp-block-heading\">If you have the exact .ACD logic that is in the processor<\/h4>\n\n\n\n<p>If you have the exact copy of the ACD file that is in the processor, simply go online with the processor.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"409\" height=\"197\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-28.png\" alt=\"\" class=\"wp-image-6073 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-28.png 409w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-28-300x144.png 300w\" data-sizes=\"(max-width: 409px) 100vw, 409px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 409px; --smush-placeholder-aspect-ratio: 409\/197;\" \/><\/figure>\n\n\n\n<p>At this point, you will notice &#8220;Faulted&#8221; Appears in the online toolbar.   Hit your drop down box, and &#8220;Go to Faults&#8221;<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"869\" height=\"601\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29.png\" alt=\"\" class=\"wp-image-6074 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29.png 869w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29-300x207.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29-768x531.png 768w\" data-sizes=\"(max-width: 869px) 100vw, 869px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 869px; --smush-placeholder-aspect-ratio: 869\/601;\" \/><\/figure>\n\n\n\n<p>Now, you will see where the fault is located.  In this case, the fault is on Rung 0.  This is in the MainTask, in the MainProgram, and in the MainRoutine.  We have a negative value for timer preset in this example.<\/p>\n\n\n\n<p>We&#8217;ll &#8220;ClearMajors&#8221;, then fix the problem in logic.<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">If you do not have a file for the processor<\/h4>\n\n\n\n<p>Obviously, if you have no .ACD file at all, then you will not be downloading to the processor.  With this in mind, we might just want to clear the fault so we can run again.<\/p>\n\n\n\n<p>In this case, go to Communication | Who Active.  <\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"413\" height=\"198\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-30.png\" alt=\"\" class=\"wp-image-6075 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-30.png 413w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-30-300x144.png 300w\" data-sizes=\"(max-width: 413px) 100vw, 413px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 413px; --smush-placeholder-aspect-ratio: 413\/198;\" \/><\/figure>\n\n\n\n<p>At this point find your <strong>PROCESSOR <\/strong>and go online.   It&#8217;s important to realize it&#8217;s the <strong>PROCESSOR <\/strong>that we need to highlight.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"721\" height=\"377\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-31.png\" alt=\"\" class=\"wp-image-6076 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-31.png 721w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-31-300x157.png 300w\" data-sizes=\"(max-width: 721px) 100vw, 721px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 721px; --smush-placeholder-aspect-ratio: 721\/377;\" \/><\/figure>\n\n\n\n<p>Choose Select File.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"831\" height=\"620\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-32.png\" alt=\"\" class=\"wp-image-6077 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-32.png 831w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-32-300x224.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-32-768x573.png 768w\" data-sizes=\"(max-width: 831px) 100vw, 831px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 831px; --smush-placeholder-aspect-ratio: 831\/620;\" \/><\/figure>\n\n\n\n<p>Press &#8220;Select&#8221; again to create a file on your hard drive.  Basically, since this is a new file, you may not have documentation.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"622\" height=\"136\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-33.png\" alt=\"\" class=\"wp-image-6078 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-33.png 622w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-33-300x66.png 300w\" data-sizes=\"(max-width: 622px) 100vw, 622px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 622px; --smush-placeholder-aspect-ratio: 622\/136;\" \/><\/figure>\n\n\n\n<p>Create the file and upload.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"342\" height=\"145\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-34.png\" alt=\"\" class=\"wp-image-6079 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-34.png 342w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-34-300x127.png 300w\" data-sizes=\"(max-width: 342px) 100vw, 342px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 342px; --smush-placeholder-aspect-ratio: 342\/145;\" \/><\/figure>\n\n\n\n<p>Next, Go to Faults.<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"869\" height=\"601\" data-src=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29.png\" alt=\"\" class=\"wp-image-6074 lazyload\" data-srcset=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29.png 869w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29-300x207.png 300w, https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29-768x531.png 768w\" data-sizes=\"(max-width: 869px) 100vw, 869px\" src=\"data:image\/svg+xml;base64,PHN2ZyB3aWR0aD0iMSIgaGVpZ2h0PSIxIiB4bWxucz0iaHR0cDovL3d3dy53My5vcmcvMjAwMC9zdmciPjwvc3ZnPg==\" style=\"--smush-placeholder-width: 869px; --smush-placeholder-aspect-ratio: 869\/601;\" \/><\/figure>\n\n\n\n<p>Finally, you will see a description of the error, and the location if it&#8217;s available.   You can clear the faults, then place your processor back into run mode.  <\/p>\n\n\n\n<p>For more information, visit the <a href=\"https:\/\/bryceautomation.com\/index.php\/category\/controllogix\/\">ControlLogix Category Page!<\/a><\/p>\n\n\n\n<p>&#8212; Ricky Bryce<\/p>\n<div id=\"bryce-3561968058\" class=\"bryce-after-content bryce-entity-placement\"><script async src=\"\/\/pagead2.googlesyndication.com\/pagead\/js\/adsbygoogle.js?client=ca-pub-8316758073402323\" crossorigin=\"anonymous\"><\/script><ins class=\"adsbygoogle\" style=\"display:block;\" data-ad-client=\"ca-pub-8316758073402323\" \ndata-ad-slot=\"4667596182\" \ndata-ad-format=\"auto\"><\/ins>\n<script> \n(adsbygoogle = window.adsbygoogle || []).push({}); \n<\/script>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Introduction: &#8220;Can&#8217;t Download to Faulted Controller&#8221; If you get the error &#8220;Can&#8217;t Download to Faulted Controller&#8221;, we need to clear the fault before downloading. First of all, be sure you want to download to the processor. When you download, the existing logic is replaced by the logic in your offline project. It&#8217;s important to realize <a class=\"moretag btn btn-primary\" href=\"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/\">Read More \u00bb<\/a><\/p>\n","protected":false},"author":1,"featured_media":6074,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[314,11,275],"class_list":{"0":"post-6063","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-controllogix","8":"tag-cant-download","9":"tag-controllogix","10":"tag-fault","11":"czr-hentry"},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Can&#039;t Download to Faulted Controller - Bryce Automation<\/title>\n<meta name=\"description\" content=\"How to resolve the &quot;Can&#039;t Download to Faulted Controller&quot; error (734-8004204F) in ControlLogix, to get back into run mode.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Can&#039;t Download to Faulted Controller - Bryce Automation\" \/>\n<meta property=\"og:description\" content=\"How to resolve the &quot;Can&#039;t Download to Faulted Controller&quot; error (734-8004204F) in ControlLogix, to get back into run mode.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/\" \/>\n<meta property=\"og:site_name\" content=\"Bryce Automation\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/ricky.bryce.7\" \/>\n<meta property=\"article:published_time\" content=\"2021-02-04T12:45:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29.png\" \/>\n\t<meta property=\"og:image:width\" content=\"869\" \/>\n\t<meta property=\"og:image:height\" content=\"601\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Ricky\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/\"},\"author\":{\"name\":\"Ricky\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"headline\":\"Can&#8217;t Download to Faulted Controller\",\"datePublished\":\"2021-02-04T12:45:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/\"},\"wordCount\":461,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2021\\\/02\\\/image-29.png\",\"keywords\":[\"Can&#039;t Download\",\"ControlLogix\",\"fault\"],\"articleSection\":[\"ControlLogix\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/\",\"name\":\"Can't Download to Faulted Controller - Bryce Automation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2021\\\/02\\\/image-29.png\",\"datePublished\":\"2021-02-04T12:45:59+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\"},\"description\":\"How to resolve the \\\"Can't Download to Faulted Controller\\\" error (734-8004204F) in ControlLogix, to get back into run mode.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/#primaryimage\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2021\\\/02\\\/image-29.png\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/uploads\\\/2021\\\/02\\\/image-29.png\",\"width\":869,\"height\":601,\"caption\":\"Go to faults\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/2021\\\/02\\\/04\\\/cant-download-to-faulted-controller\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/bryceautomation.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Can&#8217;t Download to Faulted Controller\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#website\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/\",\"name\":\"Bryce Automation\",\"description\":\"Automating Home and Industry...\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/bryceautomation.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/#\\\/schema\\\/person\\\/5d5b0f6f6ad768f1ee52968338e63af7\",\"name\":\"Ricky\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"url\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"contentUrl\":\"https:\\\/\\\/bryceautomation.com\\\/wp-content\\\/wphb-cache\\\/gravatar\\\/a8f\\\/a8fe6bf79d292b388ffee281ccb12488x96.jpg\",\"caption\":\"Ricky\"},\"sameAs\":[\"http:\\\/\\\/bryceautomation.com\",\"https:\\\/\\\/www.facebook.com\\\/ricky.bryce.7\",\"https:\\\/\\\/www.linkedin.com\\\/in\\\/ricky-bryce-4367a416\\\/\"],\"url\":\"https:\\\/\\\/bryceautomation.com\\\/index.php\\\/author\\\/ricky\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Can't Download to Faulted Controller - Bryce Automation","description":"How to resolve the \"Can't Download to Faulted Controller\" error (734-8004204F) in ControlLogix, to get back into run mode.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/","og_locale":"en_US","og_type":"article","og_title":"Can't Download to Faulted Controller - Bryce Automation","og_description":"How to resolve the \"Can't Download to Faulted Controller\" error (734-8004204F) in ControlLogix, to get back into run mode.","og_url":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/","og_site_name":"Bryce Automation","article_author":"https:\/\/www.facebook.com\/ricky.bryce.7","article_published_time":"2021-02-04T12:45:59+00:00","og_image":[{"width":869,"height":601,"url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29.png","type":"image\/png"}],"author":"Ricky","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/#article","isPartOf":{"@id":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/"},"author":{"name":"Ricky","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"headline":"Can&#8217;t Download to Faulted Controller","datePublished":"2021-02-04T12:45:59+00:00","mainEntityOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/"},"wordCount":461,"commentCount":0,"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29.png","keywords":["Can&#039;t Download","ControlLogix","fault"],"articleSection":["ControlLogix"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/","url":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/","name":"Can't Download to Faulted Controller - Bryce Automation","isPartOf":{"@id":"https:\/\/bryceautomation.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/#primaryimage"},"image":{"@id":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/#primaryimage"},"thumbnailUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29.png","datePublished":"2021-02-04T12:45:59+00:00","author":{"@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7"},"description":"How to resolve the \"Can't Download to Faulted Controller\" error (734-8004204F) in ControlLogix, to get back into run mode.","breadcrumb":{"@id":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/#primaryimage","url":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29.png","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/uploads\/2021\/02\/image-29.png","width":869,"height":601,"caption":"Go to faults"},{"@type":"BreadcrumbList","@id":"https:\/\/bryceautomation.com\/index.php\/2021\/02\/04\/cant-download-to-faulted-controller\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/bryceautomation.com\/"},{"@type":"ListItem","position":2,"name":"Can&#8217;t Download to Faulted Controller"}]},{"@type":"WebSite","@id":"https:\/\/bryceautomation.com\/#website","url":"https:\/\/bryceautomation.com\/","name":"Bryce Automation","description":"Automating Home and Industry...","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/bryceautomation.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/bryceautomation.com\/#\/schema\/person\/5d5b0f6f6ad768f1ee52968338e63af7","name":"Ricky","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","url":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","contentUrl":"https:\/\/bryceautomation.com\/wp-content\/wphb-cache\/gravatar\/a8f\/a8fe6bf79d292b388ffee281ccb12488x96.jpg","caption":"Ricky"},"sameAs":["http:\/\/bryceautomation.com","https:\/\/www.facebook.com\/ricky.bryce.7","https:\/\/www.linkedin.com\/in\/ricky-bryce-4367a416\/"],"url":"https:\/\/bryceautomation.com\/index.php\/author\/ricky\/"}]}},"_links":{"self":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/6063","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/comments?post=6063"}],"version-history":[{"count":0,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/posts\/6063\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media\/6074"}],"wp:attachment":[{"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/media?parent=6063"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/categories?post=6063"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/bryceautomation.com\/index.php\/wp-json\/wp\/v2\/tags?post=6063"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}